Background: The main diagnostic methods for evaluating repaired menisci include second-look arthroscopy, clinical assessment, and magnetic resonance imaging (MRI). None of the previous studies applied all 3 methods for each consecutive case nor made any systematic comparison among them.
Purpose: This study was undertaken to compare the diagnostic values of the 3 different methods in an attempt to propose suggestions for evaluating meniscal healing results.
Study Design: Cohort study (diagnosis); Level of evidence, 2.
Methods: Eighty-one patients (89 menisci), with a mean age of 25.4 years (standard deviation [SD], 7.7; range, 15-50 years), underwent arthroscopic meniscal repair, including 65 medial menisci and 24 lateral menisci. Follow-up evaluation for each meniscus included clinical assessment, second-look arthroscopy, and postoperative MRI, with a mean follow-up time of 25.4 months (SD, 6.0; range, 17.4-48.3 months). Defined criteria for unhealed meniscus were any symptoms such as joint-line tenderness, swelling, locking, or positive McMurray test for clinical assessment; cleft or instability on second-look arthroscopy; and grade 3 signal intensity shown at the repaired site on postoperative MRI.
Results: Seventy-seven menisci were confirmed completely healed by second-look arthroscopy, with a total healing rate of 86.5%. Clinical assessment found 63 menisci healed, with a clinical healing rate of 70.8% (sensitivity, 58.3%; specificity, 75.3%; accuracy, 73.0%). By using the second-look arthroscopy as the standard, the sensitivity, specificity, and accuracy, respectively, were calculated for MRI in 5 sequences: sagittal T1: 91.7%, 58.4%, 62.9%; sagittal proton density (PD): 83.3%, 40.3%, 46.1%; sagittal T2: 58.3%, 89.6%, 85.4%; coronal PD: 75.0%, 74.0%, 74.2%; and coronal T2: 41.7%, 98.7%, 91.0%.
Conclusion: Second-look arthroscopy was the most dependable way to determine meniscal healing. Clinical assessment had obvious limitations in diagnosing healed menisci. On MRI examination, T2-weighted sequences had obviously higher specificity and accuracy, while PD and T1 had higher sensitivity. The diagnostic value could be improved by a combined application of different sequences.
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.
0.00 MB
0.01 MB
0.03 MB
0.01 MB