Drummond AH, Beckett P., Brown PD, et al: Preclinical and clinical studies of MMP inhibitors in cancer. Inhibition of matrix metalloproteinases. Ann N Y Acad Sci878: 225-234, 1999
2.
Kashida Y., Kato M.: Characterization of fluoroquinolone-induced Achilles tendon toxicity in rats: Comparison of toxicities of 10 fluoroquinolones and effects of anti-inflammatory compounds. Antimicrob Agents Chemother41: 2389-2393, 1997
3.
Kaplan L., Uribe JW: The acute effects of radiofrequency energy in articular cartilage: An in vitro study. Arthroscopy16: 2-5, 2000
4.
Lu Y., Edwards III RB, Cole BJ, et al: Thermal chondroplasty with radiofrequency energy: An in vitro comparison of bipolar and monopolar radiofrequency devices. Am J Sports Med29: 42-49, 2000
5.
Turner AS, Tippett JW, Powers BE, et al: Radiofrequency (electrosurgical) ablation of articular cartilage: A study in sheep. Arthroscopy14: 585-591, 1998
6.
Obrzut SL, Hecht P., Hayashi K., et al: The effect of radiofrequency energy on the length and temperature properties of the glenohumeral joint capsule. Arthroscopy14: 385-400, 1998
7.
Shellock FG: RF energy-induced heating of bovine capsular tissue produced by bipolar vs. monopolar RF electrodes. Arthroscopy: in press, 2001
8.
Shellock FG, Shields CLJr: Temperature changes associated with radiofrequency energy-induced heating of bovine capsular tissue: Evaluation of bipolar RF electrodes. Arthroscopy16: 348-358, 2000
9.
Fayard JP, Chambat P., Christel P., et al: Biocompatibility of a bioabsorbable interference screw until total resorption in a functional sheep model. Proceedings of the EFFORT Congress, June 3-8, 1999; Brussels. Abstract 218.
10.
Li SM, Vert M.: Crystalline oligomeric stereocomplex as intermediate compound in racemic poly (D,L-lactic acid) degradation. Polym Inter33: 37-41, 1994
11.
Matsusue Y., Hanafusa S., Yamamuro T., et al: Tissue reaction of bioabsorbable ultra high strength poly(L-lactide) rod. A long-term study in rabbits. Clin Orthop317: 246-253, 1995
12.
Schwach G., Vert M.: In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction. Int J Biol Macromol25: 283-291, 1999
13.
Athanasiou KA , Niederauer GG, Agrawal CM: Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers . Biomaterials17: 93-102, 1996
14.
Helling H., Weiler A., Kirch U., et al: Experimental use of a new biodegradable polylactide-pin for the refixation of osteochondral fragments. Proceedings of the European Society of Sports Traumatology Knee Surgery Arthroscopy, 6th Congress, Berlin, 1994
15.
Matsusue Y., Hanafusa S., Yamamuro T., et al: Tissue reaction of bioabsorbable ultra high strength poly(L-lactide) rod. A long-term study in rabbits. Clin Orthop317: 246-253, 1995
16.
Pistner H., Bendix DR, Muhling J., et al: Poly(L-lactide): A long term study in vivo. Part III. Analytical characterization. Biomaterials14: 291-298, 1993
17.
Therin M., Chambat P., Fayar J., et al: In vivo evaluation of bioabsorbable interference screws (98%PLLA, 2% PDLLA) in sheep. Proceedings of the European Society of Sports Traumatology Knee Surgery Arthroscopy, 7th Congress, Budapest, 1996
18.
Verheyen CC, de Wijn JR, van Blitterswijk CA, et al: Examination of efferent lymph nodes after 2 years of transcortical implantation of poly(L-lactide) containing plugs: A case report. J Biomed Mater Res27: 1115-1118, 1993
19.
Weiler A., Abel C., Stähelin A., et al: In-vivo biocompatibility, degradation, and osseous replacement at a poly-(D,L-lactide) interference screw (abstract). Arthroscopy16: 421, 2000
20.
Weiler A., Helling HJ, Kirch U., et al: Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep. J Bone Joint Surg78B: 369-376, 1996
21.
Weiler A., Hoffmann RF, Stähelin AC, et al: Biodegradable implants in sports medicine-The biological base . Arthroscopy16: 305-321, 2000