Transcutaneous oxygen saturation of haemoglobin was measured in 101 patients en route from the operating room to the recovery room. Twenty-nine became significantly hypoxaemic during the journey.
The incidence of hypoxaemia was not found to relate to age, weight, duration or type of surgery, type of anaesthesia or pre-existing disease. Duration of the interval between cessation of oxygen in the operating room and arrival in recovery room was the only significant finding in patients who became hypoxaemic.
HanningCD, EllingA.Oxygenation during postoperative transportation. Syposium: The Clinical Applications of Oximetry. Ohmeda Medishield, U.K., May 1985; 29.
2.
VaughanRW, CorkRC, HollanderD.The effect of weight loss on arterial oxygenation and pulmonary function tests. Anesthesiology1981; 54:325–328.
3.
SugarmanHJ, FairmanRP. Massive weight loss will improve arterial oxygenation in selected patients. Anesthesiology1981; 55:604–605.
4.
TremperK.The theory of oximeter operation. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 6.
5.
CardenasFE. Noninvasive transanaesthetic oximetry. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 18.
6.
MisasakaK.The use of noninvasive oximetry during the induction of anaesthesia in children. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 19.
7.
DochertyP.The advantages of oximetry during paediatric anaesthesia. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 20.
8.
TorriG.Oximetry during one lung anaesthesia. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 25.
9.
ThorntonJA. The use of oximetry in dental outpatients undergoing controlled sedation and general anaesthesia. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 26.
10.
CecilWT, PettersonMT, LamoonponS, RudolphCD. Clinical evaluation of the Biox 11 A ear oximeter in the critical care environment. Respiratory Care 1985 30; 3:179–183.
11.
DautzenbergB.The benefits of real time oximetry over intermittent arterial blood gases in a chest department. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 14–16.
12.
VuoriA.A comparison of pulse oximetry with invasive mixed venous saturation monitoring. Symposium: The clinical applications of oximetry. Ohmeda, U.K., May 1985; 10.
13.
RebuckAS, ChapmanKR, D'UrzoA.The accuracy and response characteristics of a simplified ear oximeter. Chest1983; 860–864.
14.
ShippyMB, PettersonMT, WhitmanRA, ShioversCR. A clinical evaluation of the BT1 Biox 11 ear oximeter. Respiratory Care1984; 29:730–735.