The Myocardial Supply: Demand Ratio reflects the ratio of subendocardial perfusion to subendocardial oxygen demands. A method is described for calculating and continuously monitoring the Myocardial Supply: Demand Ratio using a digital computer in real-time.
BregmanD., ParodiE.N., EdieR.N., BowmanF.O., ReemtsmaK., MalmJ.R.Intraoperative unidirectional intra-aortic balloon pumping in the management of left ventricular power failure. J Thorac Cardiovasc Surg1975; 70: 1010–1023.
3.
BrodyW.R., ReitzB.A., AndrewsM.J., RobertsW.C., MichaelisL.L.Long-term morphologic and hemodynamic evaluation of the left ventricle after cardiopulmonary bypass. J Thorac Cardiovasc Surg1975; 70: 1073–1087.
4.
BuckbergG.D., FixlerD.E., ArchieJ.P., HoffmanJ.I.E.Experimental subendocardial ischemia in dogs with normal coronary arteries. Circ Res1972; 30: 67–81.
5.
SarnoffS.J., BraunwaldE., WelchG.H., CaseR.B., StainsbyW.N., MacruzR.Hemodynamic determinants of oxygen consumption of the heart with special reference to the tension-time index. Am J Physiol1958; 192: 148–156.
6.
BrazierJ., CooperN., BuckbergG.The adequacy of subendocardial oxygen delivery. The interaction of determinants of flow, arterial oxygen content and myocardial oxygen need. Circ1974; 49: 968–977.
7.
HoffmanJ.I.E., BuckbergG.D.The myocardial supply: demand ratio — a critical review. Am J Cardiol1978; 41: 327–332.
8.
GunstensenJ., ScullyH.E., KellyT., AdelmanA.G., WilliamsW.G., WigleE.D., GoldmanB.S.Prognostic significance of endocardial viability ratio in aortocoronary bypass surgery. Canad J Surg1976; 19: 93–96.
9.
PhilipsP.A., BregmanD.Intraoperative application of intraaortic balloon counterpulsation determined by clinical monitoring of the endocardial viability ratio. Ann Thorac Surg1977; 23: 45–51.
10.
PhilipsP.A., MartyA.T., MiyamotoA.M.A clinical method for detecting subendocardial ischemia after cardiopulmonary bypass. J Thorac Cardiovasc Surg1975; 69: 30–39.
11.
Seybold-EptingW., HuthC., FenchelG., StunkatR., HoffmeisterH.E.Estimation of adequate subendocardial blood flow by online computation of systolic pressure time index and diastolic pressure time index after cardiopulmonary bypass. J Cardiovas Surg (Turin)1978; 19: 465–470.
12.
OliverosR.A., BoucherC.A., GrovesB.M., UhlG.S.Myocardial supply-demand ratio in aortic regurgitation. Chest1979; 76: 50–55.
13.
BarnardR.J., MacAlpinR., KattusA.A., BuckbergG.D.Ischemic response to sudden strenuous exercise in healthy men. Circ1973; 48: 936–942.
14.
HallB.R., CrankshawD.P.Computer system for interactive data management. Anaesth Intens Care1979; 7: 198.
15.
WesselingK.H., PurschkeR., Ty SmithN., SchultzH.D., WeberH.A.P.A beat-to-beat cardiac output computer for clinical monitoring. Real Time Computing in Patient Management.Peter Peregrinus Ltd. Herts.England. 1976; 92–107.