Electroencephalogram depth of anaesthesia monitors are increasingly being used, with the aim of reducing awareness during anaesthesia. Most literature concentrates on the ability of these monitors to predict when a patient is likely to be aware. This case report highlights the opposite problem, where the monitor (M-Entropy™) indicated an awake state but the patient was in fact deeply anaesthetised. If the anaesthetist is unable to interpret the raw electroencephalogram and understand the limitations of the monitor being used, excessive doses of anaesthetic may be given with potentially serious consequences.
MylesP.S., LeslieK., ForbesA., ChanM.T.V.Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial. Lancet2004; 363: 1757–1763.
2.
AvidanM.S., ZhangL., BurnsideB.A., FinkelK.J., SearlemanA.C., SelvidgeJ.A.Anaesthesia Awareness and the Bispectral Index. N Engl J Med2008; 358: 1097–1108.
3.
EkmanA., IinholmM-L, LennmarkenC., SandinR.Reduction in the incidence of awareness using BIS monitoring. Acta Anaesthesiol Scand2004; 48: 20–26.
4.
BarnardJ.P., BennettC., VossL.J., SleighJ.W.Can anaesthetists be taught to interpret the effects of general anaesthesia on the electroencephalogram? Comparison of performance with the BIS and spectral entropy. Br J Anaesth2007; 99: 532–537.
5.
BennettC., VossL.J., BarnardJ.P.M., SleighJ.W.Practical use of the raw electroencephalogram waveform during general anaesthesia: the art and the science. Anesth Analg2009; 109: 539–550.
6.
OlofsenE., SleighJ.W., DahanA.Permutation entropy of the electroencephalogram: a measure of anaesthetic drug effect. Br J Anaesth2008; 101: 810–821.
7.
SoehleM., EllerkmannR.K., GrubeM., KuechM., WirzS., HoeftA.Comparison between bispectral index and patient state index as measures of the electroencephalographic effects of sevoflurane. Anesthesiology2008; 109: 799–805.
8.
VakkuriA., Yli-HankalaA., TaljaP., MustolaS., Tolvanen-LaaksoH., SampsonT.Time frequency balanced spectral entropy as a measure of anaesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anaesthesiaActa Anaesthesiol Scand2004; 48: 145–153.
9.
Viertiö-OjaH., MajaV., SärkeläM., TaljaP., TenkanenN., Tolvanen-LaaksoH.Description of the Entropy™ algorithm as applied in the Datex-Ohmeda S/5™ Entropy module. Acta Anaesthesiol Scand2004; 48: 154–161.
10.
SarkelaM., MustolaS., SeppanenT., KoskinenM., LepolaP., SuominenK.Automatic analysis and monitoring of burst suppression in anesthesiaJ Clin Monit Comput2002; 17: 125–134.