Ten deep-frozen temporal bone specimens were subjected to computed tomography (CT) in five different projections. The possibility of identifying small structures, such as the ossicles and aqueductal lumina, was assessed. In addition, the semicircular canals were measured. Subsequently corresponding measurements were carried out on plastic casts of these specimens for comparison. A temporal bone specimen is well suited as a test object for evaluating the detectability of small and dense natural structures by CT.
BastT. H.AnsonB. J.: The temporal bone and the ear. Charles C. Thomas, Springfield, Illinois1949.
2.
BeattyC. W.HarrisL. D.SuhK. W.ReeseD.: Comparative study using computed tomographic thin-section zoom reconstructions and anatomic macrosections of the temporal bone. Ann. Otol.90 (1981), 643.
3.
BhimaniS.VirapongseC.SarwarM.: High resolution computed tomographic appearance of normal cochlear aqueduct. Amer. J. Neuroradiol.5 (1984), 715.
4.
ChakeresD. W.: CT of ear structures. A tailored approach. Radiol. Clin. N. Amer.22 (1984), 3.
5.
ChakeresD. W.: Clinical significance of partial volume averaging of the temporal bone. Amer. J. Neuroradiol.5 (1984), 297.
6.
ChakeresD. W.SpiegelP. K.: A systematic technique for comprehensive evaluation of the temporal bone by computed tomography. Radiology146 (1983), 97.
7.
ChakeresD. W.WeiderD. J.: Computed tomography of the ossicles. Neuroradiology27 (1985), 99.
8.
DamsmaH.ZonneveldF. W.van WaesP. F. G. M.GrootJ. A. M.: The value of the direct semilongitudinal CT-plane in the preoperative evaluation of petrous bone pathology. Rev. Laryngol. Otol. Rhinol.104 (1983), 395.
9.
DreisbachJ.SeibertC.ArenbergKaufman I.: Patency and visibility of the vestibular aqueduct in Menière's disease. Otolaryng. Clin. N. Amer.16 (1983), 103.
10.
FischgoldH.: Harmonisation et renforcement du contraste. In:Bildgüte in der Radiologie, p. 297. Gustav Fischer Verlag, Stuttgart1966.
11.
FrikW.: Methoden zur Kennzeichnung der Bildqualität. In:Bildgüte in der Radiologie, p. 45. Gustav Fischer Verlag, Stuttgart1966.
12.
GoodenoughD. J.WeaverK. E.: Factors related to low contrast resolution in CT scanners. Comput. Radiol.8 (1984), 297.
13.
HenschkeF.KalenderW.PeschH. J.RettingerG.: Relevanz der Computertomographie für die Feinstrukturanalyse von Knochen. Morphol. Med.3 (1983), 157.
14.
HounsfieldG. N.: Picture quality of computed tomography. Amer. J. Roentgenol.127 (1976), 3.
15.
KoehlerP. R.AndersonR. E.BaxterB.: The effect of computed tomography viewer controls on anatomical measurements. Radiology130 (1979), 189.
16.
KönigH.KurtzB.: Hochauflösende Computertomographie der Felsenbeine. Fortschr. Röntgenstr.141 (1984), 129.
17.
LamotheA.Brazeau-LamontagneL.BergeronD.PoliquinJ.StromB.: High resolution CT scan of the temporal bone. J. Otolaryngol.12 (1983), 119.
18.
LittletonJ. T.ShafferK. A.CallahanW. P.DurizchM. L.: Temporal bone. Comparison of pluridirectional tomography and high resolution computed tomography. Amer. J. Roentgenol.137 (1981), 835.
19.
LloydG. A. S.Du BoulayG. H.PhelpsP. D.PullicinoP.: The demonstration of the auditory ossicles by high resolution CT. Neuroradiology18 (1979), 243.
20.
LufkinR.BarniJ. J.GlenW.MancusoA.CanalisR.HanafeeW.: Comparison of computed tomography and pluridirectional tomography of the temporal bone. Radiology143 (1982), 715.
21.
MurenC.RuhnG.WilbrandH.: Anatomic variations of the human semicircular canals. Acta Radiol. Diagnosis27 (1986), 157.
22.
OlsonJ. E.DorwartR. H.BrantW. E.: Use of high resolution thin section CT scanning of the petrous bone in temporal bone anomalies. Laryngoscope92 (1982), 1274.
23.
RöhlerR.: Methoden zur Kennzeichnung der Bildqualität. Physikalische Gesichtspunkte. In:Bildgüte in der Radiologie, p. 56. Gustav Fischer Verlag, Stuttgart1966.
24.
SchottO.: Die Modulationsübertragungsfunktion in der Röntgenologie. In:Bildgüte in der Radiologie, p. 68. Gustav Fischer Verlag, Stuttgart1966.
25.
SchultzE.FelixR.: Phantommessungen zum räumlichen Auflösungsvermögen und zum Partial-Volume-Effect bei der Computertomographie. Fortschr. Röntgenstr.129 (1978), 673.
26.
ShafferK. A.: Comparison of computed tomography and complex motion tomography in the evaluation of cholesteatoma. Amer. J. Neuroradiol.5 (1984), 303.
27.
StahleJ.WilbrandH.: The vestibular aqueduct in patients with Menière's disease. Acta Otolaryngol.78 (1974), 36.
28.
SwartzJ.KamalR.WolfsonR.MarloweF.: High resolution computed tomography in evaluation of the temporal bone. Head Neck Surg.6 (1984), 921.
29.
ValavanisA.KubikS.OguzM.: Exploration of the facial nerve canal by high-resolution computed tomography. Anatomy and pathology. Neuroradiology24 (1983), 139.
30.
VirapongseC.RothmanS.KierE. L.SarwarM.: Computed tomographic anatomy of the temporal bone. Amer. J. Roentgenol.139 (1982), 739.
31.
WilbrandH. F.: The vestibular and cochlear aqueduct. Rev. Laryngol.105 (1984), 101.
32.
WilbrandH. F.RauschningW.: Investigation of temporal bone anatomy by plastic moulding and cryomicrotomy. Acta Radiol. Diagnosis27 (1986), 389.
33.
ZonneveldF. W.: The value of non-reconstructive multiplanar CT for the evaluation of the petrous bone. Neuroradiology25 (1983), 1.