BotdenP. J. M.: Introduction to X-ray television. Medica Mundi4 (1958), 73.
14.
BronkhorstW.: Kontrast und Schärfe im Röntgenbilde. Thieme, Leipzig 1927.
15.
BrooksV. B.: Contrast and stability in the nervous system. Trans. N. Y. Acad. Sci.21 (1959), 387.
16.
BouwersA.: Information content of X-ray pictures made with the various new techniques. 9th Intern. Congress Radiology. Vol. 2, p. 1466. Georg Thieme, Stuttgart1961.
17.
BurgerG. C. E.: Phantom tests with X-rays. Philips Technical Rev.11 (1950), 291.
18.
BurgerG. C. E.The perceptibility of detail in roentgen examination of the lungs. Acta radiol.31 (1949), 193.
19.
BurgerG. C. E. and van DijkB.: Über die physiologischen Grundlagen der Durchleuchtung. Fortschr. Röntgenstr.54 (1936), 492.
20.
BurgerG. C. E.CombeeB.van der TuukJ. H.: X-ray fluoroscopy with enlarged image. Philips Techn. Rev.8 (1946), 321.
21.
BurgerG. C. E.BotdenP. J. M.LanooyC.: Proc. 7th Intern. Congress Radiology, Copenhagen 1953.
22.
CampbellJ. W.KlatteE. C.GrayD.McCreaA. L.: Evaluation of film size in cineradiography. Radiology76 (1961), 606.
23.
ChamberlainW. E.: Fluoroscopes and fluoroscopy. Radiology38 (1942), 383.
24.
ColtmannJ. W.: Specification of imaging properties by response to a sine-wave input. J. Opt. Soc. of America44 (1954), 468.
25.
ColtmannJ. W.Scintillation limit in fluoroscopy. Radiology63 (1954), 867.
26.
DawesW. R.: Catalogues of micrometrical measurements of double stars. Mem. Roy. Astron. Soc.35 (1867), 137.
27.
DitchburnR. W.: Notes on resolving power. Proc. Roy. Irish Acad.39 (1930), 58.
28.
DowdyA. H.BonnanL. J.: Simulated color roentgenography. Amer. J. Roentgenol.70 (1953), 581.
29.
EagleA.: Fourier's theorem and harmonic analysis. Longmans, Green & Co, London 1925.
30.
EagleshamD. C.: Factors determining quality in a radiograph. J. Canad. Ass. Radiol.11 (1960), 67, 89.
31.
FoucaultL.: Mémoire sur la construction des télescopes en verre argente. Ann. Observatoire imp. Paris5 (1859), 197.
32.
FrantzellA.: The effect of focal size, shape and structure on the roentgenographic representation of small calibre metal objects. Acta radiol.35 (1951), 265.
33.
GarlandL. H.: Studies on the accuracy of diagnostic procedures. Amer. J. Roentgenol.82 (1959), 25.
34.
GarlandL. H.Role of fluoroscopy in the diagnosis of pulmonary tuberculosis. Amer. Rev. Tuberc.45 (1942), 1.
35.
GibsonE. J.: Improvement in perceptual judgements as a function of controlled practice or training. Psychol. Bull.50 (1953), 401.
MatsudaH.NagaokaT.TakaiG.MinomiyaJ.: Medical applications of X-ray television. Amer. J. Roentgenol.85 (1961), 352.
54.
MeesC. E. K.: The theory of the photographic process. MacMillan Co, New York 1954.
55.
MorganR. H.: An analysis of the physical factors controlling the diagnostic quality of roentgen images. Part I. Maximum resolving power and resolution coefficient. Part II. Amer. J. Roentgenol.54 (1945), 128, 395. Contrast and the intensity distribution function of a roentgen image. Part III. Contrast and the film contrast factor. Part IV. Amer. J. Roentgenol. 55 (1946), 67, 627.
56.
MorganR. H.Unsharpness. Amer. J. Roentgenol.62 (1949), 680.
57.
MorganR. H.Characteristics of X-ray films and screens. Radiology49 (1947), 90.
58.
MorganR. H.Screen intensification. Amer. J. Roentgenol.75 (1956), 69.
59.
MorganR. H.Development and state of television intensification in America. 9th Intern. Congress. Radiology. Vol. 1, p. 20. Georg Thieme, Stuttgart1961.
60.
MorganR. H.Measurement of radiation energy level in diagnostic roentgenology. (Area dose in fluoroscopy). Radiology76 (1961), 867.
61.
MorganR. H.The frequency response function. Amer. J. Roentgenol.88 (1962), 175.
62.
MorganR. H. and van AllenW. W.: Sensitometry of X-ray films and screens. Radiology52 (1949), 832.
63.
MuellerC. G.: Frequency of seeing functions for intensity discrimination at various levels of adapting intensity. J. gen. Physiol.34 (1951), 463.
64.
NelsonA.: Determination of the physical factors influencing the quality of the radiographic image. Acta radiol. (1949). Suppl. 76.
65.
NemetA.CoxW. F.WalkerG. B.: Blurring in radiography. Brit. J. Radiol.19 (1946), 257.
66.
NemetA.CoxW. F.WalkerG. B. and HillsT. H.: Contrast problem in high kilovolt medical radiography. Brit. J. Radiol.26 (1953), 185.
67.
NewellR. R.: Sharpness of shadows, in radiography of the lungs. Radiology30 (1938), 493.
68.
NewellR. R. and GarneauR.: The threshold visibility of pulmonary shadows. Radiology56 (1951), 409.
69.
OosterkampW. J.AlbrechtC.: Methods of evaluating new instrumental systems for diagnostic radiology. 9th Intern. Congress Radiology. Vol. 2, p. 1451. Georg Thieme, Stuttgart1961.
70.
PirenneM. H.: Light quanta and vision. Endeavour20 (1961), 197.
71.
RamseyG. H. S.: Cinefluorography.Charles C. Thomas, Springfield, Ill., 1960.
72.
RiggsS. L.RatliffJ. C.CornsweetT. N.: The disappearance of steadily fixated visual test objects. J. Opt. Soc. America43 (1953), 495.
73.
RoderickJ. F.: Plastic roentgen-ray phantoms. Amer. J. Roentgenol.81 (1959), 331.
74.
RoseA.: Sensitivity performance of the human eye on an absolute scale. J. Opt. Soc. America38 (1948), 196.
75.
RosenblithW. A.: Sensory communication. John Wiley & Sons, New York 1961.
76.
RossmanK.SeemanH. E.: Detail visibility in radiographs. Amer. J. Roentgenol.85 (1961), 366.
77.
SchadeO. H.: New system of measuring and specifying image definition. N. B. S. Circular526: 29 April 1954.
78.
SchadeO. H.Image gradation, graininess and sharpness in television and motion picture systems. Soc. M. P. T. E.58 (1952), 181.
79.
SchoberH.: Die Messung von Kontrast und Schärfe im Röntgenbild im Lichte der Informationstheorie. 9th Intern. Congress Radiology. Vol. 2, p. 1460. Georg Thieme, Stuttgart1961.
80.
SchoberH. and KlettC.: Image sharpness in radiographic intensifying screens. Röntgen Blätter7 (1954), 224.
81.
SchottO.: Betrachungen zur Bildgütebeurteilung in der Röntgendiagnostik. 9th Intern. Congress Radiology, Vol. 2, p. 1493. Georg Thieme, Stuttgart1961.
82.
SeemanH.: Physical factors which determine roentgenographic contrast. Amer. J. Roentgenol.80 (1958), 112.
83.
SeemanH. and RothB.: New stepped wedges for radiography. Acta radiol.53 (1960), 215.
84.
ShannonC.WeaverW.: The mathematical theory of communication. Univ. Ill. Press, Urbana 1949.
85.
ShearerJ. S.: The speed of intensifying screens. Amer. J. Roentgenol.1 (1913), 163.
86.
SonnenblickB. P.: Protection in diagnostic radiology. Rutgers Press, New Brunswick 1959.
87.
SpieglerG.F.R.: Physikalische Grundlagen der Röntgendiagnostik. Thieme, Stuttgart1957.
88.
SpiersF. W.: Effective atomic number and energy absorption in tissues. Brit. J. Radiol.19 (1946), 52.
89.
SplettstrosserH. R.SeemanH. E.: A phantom for physical studies in chest radiography. Radiology64 (1955), 114.
SturmR. E.MorganR. H.: Screen intensification systems and their limitations. Amer. J. Roentgenol.62 (1949), 617.
92.
SwindellsF. E.: Some properties of intensifying screens. Amer. J. Roentgenol.17 (1927), 115.
93.
SwindellsF. E.Physical properties of intensifying screens. Radiology11 (1928), 424.
94.
SwindellsF. E.Effect of speed on intensifying screens. Radiology14 (1930), 387.
95.
Ter PogossianM.LedinS.: Uranium X-ray grids. 9th Intern. Congress Radiology. Vol. 2, p. 1513. Georg Thieme, Stuttgart1961.
96.
TolT.OosterkampW. J.ProperJ.: The limit of detail perceptibility in radiology. Philips Res. Reports10 (1955), 141.
97.
TuddenhamW. J.: The visual physiology of roentgen diagnosis. Amer. J. Roentgenol.78 (1957), 116.
98.
TuddenhamW. J.Visual problems of roentgen interpretation. N. Y. St. J. Med.60 (1960), 1234.
99.
TuddenhamW. J. and CalvertW. P.: Visual search patterns in roentgen diagnosis. Radiology76 (1961), 255.
100.
Van AllenW. W.MorganR. H.: Measurements of resolving power of intensifying screens. Radiology47 (1946), 166.
101.
Van der PlaatzG. J.: Medical X-ray technique. Philips Techn. Library.Cleaver-Hume Press, London1959.
102.
WebsterE. W.AtkinA.: Contrast and detail studies in fluoroscopy with an image intensifier and television pickup. Part I. Test systems. Radiology (in press).
103.
WienerH.: Cybernetics. J. Wiley & Sons, New York 1948.
104.
WilliamsF. E.: Electroluminescence applied to fluoroscopic image intensification. Amer. J. Roentgenol.75 (1956), 77. Wilsey R. B.: The intensity of scattered X-rays in radiography. Amer. J. Roentgenol. 8 (1921), 328.
105.
WilliamsF. E.Scattered radiation in roentgenography of the chest. Radiology23 (1934), 198.
106.
WilliamsF. E.Measurement of intensifying factors of X-ray intensifying screens. Radiology2 (1924), 311.
107.
ZweigH. J.: The relation of quantum efficiency to energy and contrast-detectivity for photographic materials. Photogr. Sci. Eng.5 (1961), 142.