Abstract
Background
There currently remains a debate over the use of core needle biopsy (CNB) or fine needle aspiration (FNA) for diagnosis of thyroid nodules. The major drawbacks of previous CNB studies include heterogeneity of the study population, variable techniques, devices, and operator experience affecting the outcome of the procedure.
Purpose
To assess the diagnostic performance and safety of CNB of thyroid nodules performed by a single experienced operator in consecutive patients.
Material and Methods
From January 2012 to December 2012, 538 thyroid nodules that underwent CNB were retrospectively evaluated. All CNB procedures were performed by a single operator with 18 years of experience. The histopathology of the surgical specimens was considered as the standard reference for malignancy. A final diagnosis of benignity was made by surgery, one benign lesion on FNA and/or CNB with no change on follow-up examinations (>1 year) or benign lesion on ≥2 FNA and/or CNB. The diagnostic performance, incidence of technical failure, unnecessary surgery, and complication were evaluated.
Results
The diagnostic accuracy, sensitivity, and specificity of CNB for malignancy were 92.0%, 85.3%, and 100%, respectively. The non-diagnostic result rate of CNB was 4.8% (26/538) and the inconclusive result rate was 24.3% (131/538). The incidence of technical failure was 0.6% (3/541) and unnecessary surgery was 0.6%. The complication rate was 0.2%, without life-threatening complications. The sensitivity, specificity, and accuracy were 85.3% (156/183), 100.0% (154/154), and 92.0% (310/337), respectively.
Conclusion
CNB shows a high diagnostic performance for detection of thyroid malignancy and follicular neoplasm, with low rates of technical failure and complications.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.