A new device for transvenous interruption of the inferior vena cava is described. Based upon the Greenfield filter, upward- and downward-facing hooks prevent movement of the filter within the vein. Results of the use of the device in 143 patients after 3 months are presented and compared to other filters.
AkinsC.A.ThurerR.L.WaltmanA.C.MargoliesM.N.SchneiderR.C.A misplaced caval filter: Its removal from the heart without cardiopulmonary by pass. Arch Surg1980; 115: 1133.
2.
AllenH.A., The Kimray–Greenfield vena cava filter. A case of unusual misplacement. Cardiovasc Intervent Radiol1982; 5: 82–84.
3.
AmadorE.LiT.K.CraneC.Ligation of inferior vena cava for thrombo-embolism: Clinical and autopsy correlations in 199 cases, JAMA1968; 206: 1758–1760.
4.
BecqueO.RenaudJ.C.MillonG.CombeJ.BassandJ.P.MauratJ.P.MilleretR.Rupture partielle d'un filtre de Kimray Greenfield. Press Méd1984; 13: 1334.
5.
BerlandL.L.MaddisonF.C.BernhardU.M.Radiological follow-up of vena cava filter devices. Am J Radiol1980; 134: 1047–1052.
6.
CastanedaF.HerreraM.CraggA.H.AndA.L.Migration of two Kimray Greenfield filters to the right ventricle. Radiology1983; 149: 690–691.
7.
CimochowskiG.EvansR.H.ZarinsC.K.Greenfield filter versus Mobin Uddin umbrella: The continuing quest for the ideal method of vena cava interruption. J Thorac Cardiovasc Surg1980; 79: 358–365.
8.
DimariaG.AndreassianB.CohenG.MercierC.GreenfieldL.J.Pourquoi et comment interrompre la V.C.I.? Table ronde. Actualités chirurgicales. Masson, 1984.
9.
FriedellM.L.GoldenkanzR.J.ParsonnetU.AlpertJ.BriefD.K.BrenerB.J.AueronF.M.Migration of a Greenfield filter to the pulmonary artery: A case report, J Vasc Surg1986; 3: 929–931.
10.
GomezG.A.CutlerB.S.WheelerH.B.Transvenous interruption of the inferior vena cava. Surgery1983; 93: 612–619.
11.
GreenfieldL.J.CruteS.L.Retrieval of the Greenfield vena caval filter. Surgery1980; 88: 719–722.
12.
GreenfieldL.J.PeytonR.CruteS.L.BarnesR.Greenfield vena caval filter experience. Late results in 156 patients. Arch Surg1981; 116: 1451–1456.
13.
GreenfieldLJ.Current indications for and results of Greenfield filter placement. J Vasc Surg1984; 1: 502–504.
14.
LemoigneF.LambertH.JourdanJ.Migration d'un filtre de Kimray–Greenfield lors de sa mise en place. J Chir1982; 119: 441–442.
15.
MessmerJ.M.GreenfieldL.J.Greenfield filters: Long term radiographic follow up study. Radiology1985; 156: 613–618.
16.
MilleretR.AmatG.CurnierJ.M.Notre expérience du filtre de Greenfield. A propos de 40 observations comparées à 40 filtres ombrelles et 40 clips. J Malad Vasc1983; 8: 211.
17.
PalestranA.M.PrinceM.SimonM.Comparative in vitro evaluation of the nitinol inferior vena cava filter. Radiology1982; 145: 351.
18.
PhilipsM.R.WidrichW.C.JohnsonW.C.Perforation of the inferior vena cava by the Kimray–Greenfield filter. Surgery1980; 87: 233–235.
19.
PicconeV.A.VidaleE.YarnozM.GlassP.LeveenH.H.The late results of caval ligation. Surgery1970; 68: 980–998.
20.
RaynaudP.FauchierJ.P.CastellaniL.CharbonnierB.AlisonD.LatourF.MorandP.RouleauP.BrochierM.Prevention of pulmonary embolism by partial occlusion of the inferior vena cava. Techniques, indications, follow-up. Prog Resp Res1980; 13: 177.
21.
SchroederT.M.ElkinsR.C.GreenfieldL.J.Entrapment of sized emboli by the KMA Greenfield intracaval filter. Surgery1978; 83: 435.
22.
ScurrJ.H.JarrettP.E.M.WastellC.Treatment of recurrent pulmonary embolism. Experience with the Kimray–Greenfield vena cava filter. Ann Roy Coll Surg1983; 65: 233–234.
23.
SidanyA.N.MenzosanJ.O.Distal migration and deformation of the Greenfield vena cava filter. Surgery1986; 99: 369–372.
24.
WingredM.BernhardU.M.MaddisonF.TowneJ.B.Comparison of caval filters in the management of venous thrombo-embolism. Arch Surg1978; 113: 1264–1268.