Glantz SABiostatistics: how to detect, correct and prevent errors in the medical literature . Circulation1980; 61: 1-7.
2.
Bethune DWOrgan damage after open-heart surgery. Lancet1976; 2: 1410.
3.
Reed CC, Clark DKConduct of perfusion. Cardiopulmonary Perfusion. Houston : Texas Medical Press, 1975: 301.
4.
Keats AS, Kurosu Y., Telford J., Cooley DAAnesthetic problems in cardiopulmonary bypass for open heart surgery: experiences with 200 patients. Anesthesiol1958; 19: 501-14.
5.
van Oeveren W., Kazatchkine MD, Descamps-Latscha B., Maillet F., Fischer E., Carpentier A., Wildevuur Crh.Deleterious effects of cardiopulmonary bypass; a prospective study of bubble versus membrane oxygenation. J Thorac Cardiovasc Surg1985 ; 89: 888-99.
6.
Walton HG, Sugden EH, White JAA look at the BOS-10 and H-1500 oxygenators. JECT1982; 14: 405-9.
7.
Kzmna GD, Docherty JPA comparison of the Bentley BOS-10, Shiley S-100 and Polystan Venotherm oxygenators during high flow perfusion and moderate hypothermia. Proceed Am Soc Extra-Corp Tech1978; 6: 107-13.
8.
Massimino RM , Dyer RK, Martin J.Jr, Gough JD, Stearns GT, Karlson K.Microemboli in the arterial line and the carotid artery during perfusion with a bubble oxygenator. ASAIO J1984; 7: 155-59.
9.
Kurusz M., Butler BDProblems relating to gaseous microemboli and the use of nitrogen with bubble oxygenators (Letter to the Editor). JECT1984 ; 16: 113-14.
10.
Riley JB, Hurdle MB, Winn BA, Jallad MSProblems relating to gaseous microemboli and the use of nitrogen with bubble oxygenators (Response). JECT1984; 16: 114-15.
11.
Butler BDBiophysical aspects of gas bubbles in blood. Med Instrument1985; 19: 59-62.
12.
Kurusz M.Gaseous microemboli; sources, causes, and clinical considerations. Med Instrument1985; 19: 73-76.
13.
Bethune DWOrgan damage after open heart surgery. Lancet1976; 2: 1410.
14.
Swan H.The importance of acid base management for cardiac and cerebral protection during open heart operations. Surg Gynae Obstet1984; 158: 391-414.
15.
Keats AS, Korosu Y., Telford J., Cooley DAAnaesthetic problems in cardiopulmonary bypass for open heart surgery: experiences with 200 patients. Anaesthesiol1958; 19: 501-504.
16.
van Oeveren W., Kazatchkine MD, Descamps-Latscha B., Maillet F., Fischer E., Carpentier A., Wildevuur Crh.Deleterious effects of cardiopulmonary bypass: a prospective study of bubble versus membrane oxygenation. J Thorac Cardiovasc Surg1985 ; 89: 888-99.
17.
Pearson DT, Holden MP, Poslad SJ, Murray A., Waterhouse PSA clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators. Life Support Systems1984; 2: 252-66.
18.
Abts LR, Beyer RT, Galletti PM, Richardson PD, Karon D., Massimino R., Karlson KEComputerised discrimination of microemboli in extracorporeal circuits. Am J Surg1978; 135: 535-38.
19.
Butler BDBiophysical aspects of gas bubbles in blood. Med Instrument1985; 19: 59-62.
20.
Shaw PJ, Bates D., Cartlidge Nef, French JM, Heaviside DW, Julian DJ, Shaw DAEarly intellectual dysfunction following coronary bypass surgery. Quart J Med1986; 225: 59-68.
21.
Slogoff S., Girgis KZ, Keats ASEtiologic factors in neuropsychiatric complications associated with cardiopulmonary bypass. Anaesth Analg1982; 61: 903-11.
22.
Pearson DT, Holden MP, Poslad SJ, Murray A., Waterhouse PSA clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: gas transfer and gaseous microemboli production. Perfusion1986; 1: 15-27.
23.
Pearson DT, McArdle B., Poslad SJ, Murray A.A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: haemocompatibility studies. Perfusion1986; 1: 81-98.
24.
Pearson DT, Holden MP, Poslad SJ, Murray A., Waterhouse PSA clinical comparison of the performance characteristics of one membrane and five bubble oxygenators: gas transfer and gaseous microemboli production. Perfusion1986; 1: 15-27.
25.
Furness A., Wright G., Sanderson JMDetection of bubbles in blood vessels and extracorporeal circuits. Med Biol Eng Comput1979; 17: 534-35.
26.
Wright G., Furness A.The detection and removal of microbubbles during cardiopulmonary bypass for open-heart surgery. The Perfusionist1983; 41: 3-6.
27.
Butler BDGaseous micro emboli: concepts and considerations. JECT1983; 15: 148-55.
28.
Furness A., Wright G.Microbubble detection during cardiopulmonary bypass for open-heart surgery . Life Support Systems1985; 5: 103-9.
29.
Abts LR, Beyer RT, Galletti PM, Richardson PD, Karon D., Massimino R., Karlson KEComputerised discrimination of microemboli in extracorporeal circuits. Am J Surg1978; 135: 535-38.
30.
Pearson DT, Holden MP, Waterhouse PS, Clarke I.Gaseous microemboli during open heart surgery. Proc Amer Acad Cardiovasc Perf1983; 4: 103-109.
31.
Pearson DT, Holden MP, Poslad SJ, Murray A., Waterhouse PSA clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators. Life Support Systems1984; 2: 252-66.
32.
Hatterland K. , Semb Bkh.Gas bubble detection in fluid lines by means of pulsed doppler ultrasound. Scand J ThorCardiovasc Surg1985; 19: 119-23.
33.
Hatterland K. , Pedersen T., Semb Bkh.Comparison of bubble release from various types of oxygenators. Scand J ThorCardiovasc Surg1985; 19: 125-30.