Abstract
Introduction:
No antidote or established extracorporeal elimination strategy is available for argatroban. Hemadsorption facilitates elimination of smaller drugs.
Case Report:
A 34-year-old patient underwent urgent heart transplantation. Because of a history of heparin-induced thrombocytopenia, preoperative anticoagulation was performed with argatroban. Despite ceasing of the continuous infusion of argatroban 2 h before surgery, concentration only declined from 0.60 μg/ml to 0.58 μg/ml before surgery, and the activated clotting time (ACT) value shortly was 223 s. Microvascular bleeding had been observed when starting surgery. A CytoSorb® absorption column was integrated into the system of the heparin-anticoagulated cardiopulmonary bypass (CPB) circuit and a flow of 400 mL/min provided during the 2 h of extracorporeal circulation. The argatroban concentration after weaning from CPB was 0.04 μg/ml and satisfying hemostasis had been achieved after protamine administration.
Conclusion:
Data indicate that the CytoSorb® absorption column might be an effective tool for quick extracorporeal removal of therapeutic concentrations of argatroban.