Bjork VO.Discussions on pumps. In: Allen JG ed. Extracorporeal circulation. Springfield, IL: Charles C Thomas , 1958: 21-23.
2.
Clowes GHA , Neville WE.The membrane oxygenator. In: Allen JG ed. Extracorporeal circulation. Springfield, IL: Charles C Thomas , 1958: 81-100.
3.
Crosby WH , Furth FW.A modification of the benzidine method for measurement of haemoglobin in plasma and urine . Blood1956; 11: 380-383 .
4.
Blakney GB , Dinwoodie AJ.A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin . Clin Biochem1975; 8: 96-102 .
5.
Koller T , Hawrylenko A.Contribution to the in vitro testing of pumps for extracorporeal circulation . J Thorac Cardiovas Surg1967; 54: 22-22 .
6.
Converse Peirce E.Extracorporeal circulation for open-heart surgery. Springfield, IL: Charles C Thomas , 1969.
7.
Mulholland JW , Massey W , Shelton JC.Investigation and quantification of the blood trauma caused by the combined dynamic forces experienced during cardiopulmonary bypass . Perfusion2000; 15: 485-494 .
8.
Blackshear PL , Dorman FD , Steinbach JH.Some effects that influence hemolysis . Trans Am Soc Artif Intern Organs1965; 11: 112-117 .
9.
Bernstein EF , Blackshear PL , Keller KH.Factors influencing erythrocyte destruction in artificial organs . Am J Surg1967; 114: 116-138 .
Hansbro SD , Sharpe DAC , Catchpole Ret al.Hemolysis during CPB: An in vivo comparison of standard roller pumps, non-occlusive roller pumps and centrifugal pumps . Perfusion1999; 14: 3-10 .
12.
Rygg IH.Studies in extracorporeal circulation. The design and development of a heart-lung machine. Copenhagen: FADLs Forlag , 1973.
13.
Wright G.L’aggregation cellulaire au cours d’une circulation extra-corporelle . Les Cahiers du CECEC1976; 6: 27-37 .
14.
Wright G.Haematological effects of cardiotomy suction. In: Longmore DB ed. Towards safer cardiac surgery. Lancaster: MTP Press , 1981: 313-323.
15.
Wright G.Blood cell trauma. In: Taylor KM ed. Cardiopulmonary bypass. Principles and techniques. London: Chapman & Hall , 1986: 249-276.
16.
ten Duis HJ , de Jong JCF , van Asseldonk AGMet al.Improved hemocompatibility in open heart surgery . Trans ASAIO1978; 24: 656-661 .
17.
Wright G.The mechanics of cell trauma in cardiotomy suction systems . Proc 3rd Ann Symp Workshop on Blood Transfusion. Groningen-Drenthe, 1978: 219-222 .
18.
Wright G , Sanderson JM.Cellular aggregation and trauma in cardiotomy suction systems . Thorax1979; 34: 621-628 .
Barthelemy R , Vives M , Couzy Met al.Dispositif de controle automatique des aspirations chirurgicales en chirugie cardiaque . Med Biol Eng Comput1978; 16: 165-168 .
21.
de Jong JF , ten Duis JH , Smit Sibinga CT , Wildevuur CRH.Haematologic aspects of cardiotomy suction in cardiac operations . J Thorac Cardiovasc Surg1980; 79: 227-236 .
22.
Teveaearai HT , Mueller XM , Horisberger Get al.In situ control of cardiotomy suction reduces blood trauma . ASAIO J1998; 44: M380-M387 .
23.
Wright G , Zhang SF.A low trauma cardiotomy suction system for use in open-heart surgery . Proc 20th Ann Int Conf IEEE/EMBS, Hong Kong, 1998.
24.
Malinauskas RA , Sade RM , Dearing JPet al.Blood damaging effects in cardiotomy suction return . JECT1988; 20: 41-46 .