Westaby S , Katsumata T.Long-term implantable circulatory support . Br J Hosp Med1997; 57: 333-338 .
2.
DeRose JJ, Jr , Argenziano M , Sun BCet al.Implantable left ventricular assist devices: an evolving long-term cardiac replacement therapy . Ann Surg1997; 226: 461-470 .
3.
Westaby S.The need for artificial hearts . Heart1996; 76: 200-206 .
4.
Minami K , Arusoglu L , El-Banayosy Aet al.Bridging for heart transplantation by different types of ventricular assist device. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 81-90.
5.
McCarthy PM , Portner PM , Tobler HG , Starnes VA , Ramasamy N , Oyer PE.Clinical experience with the Novacor ventricular assist system: bridge to transplantation and the transition to permanent application . J Thorac Cardiovasc Surg1991; 102: 578-587 .
6.
Frazier OH , Myers TJ , Radovancevic B.The Heart-Mate left ventricular assist system overview and 12- year experience . Texas Heart Inst J1998; 25: 265-271 .
Frazier OH , Rose EA , Macmanus Qet al.Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device . Ann Thorac Surg1992; 53: 1080-1090 .
9.
Yamazaki K , Mori T , Tomioka Jet al.The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps . ASAIO J1997; 43: M567-M571 .
10.
Walowit JA , Malanoski SB , Horvath D , Golding LR , Smith WA.The analysis, design, and testing of a blood lubricated hydrodynamic journal bearing . ASAIO J1997; 43: M556-M559 .
11.
DeBakey ME , Benkowski R.The Debakey/NASA axial flow ventricular assist device. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 407-413.
12.
Wieselthaler GM , Schima H , Laufer Get al.First bridge to cardiac transplantation with the Debakey VAD axial flow pump [Abstract] . Artif Organs1999; 23: 681-681 .
13.
Litwak P , Poirier V , Butler K.In vivo development tests of an axial flow pump based LVAS [Abstract] . Artif Organs1999; 23: 678-678 .
14.
Frazier OH.New technologies in the treatment of severe cardiac failure: the Texas Heart Institute Experience . Ann Thorac Surg1995; 592 Suppl: S31-S38 .
15.
Takami Y , Nakazawa T , Mkinouchi Ket al.Alumina ceramic and polyethylene: materials for double pivot bearing system of an implantable centrifugal ventricular assist device. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 139-147.
16.
Sakuma I , Fukui Y , Dohi T.Study of secondary flow in centrifugal blood pumps using a flow visualization method with a high-speed video camera . Artif Organs1996; 20: 541-545 .
17.
Takami Y , Nakazawa T , Makinouchi Ket al.Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump . Artif Organs1997; 21: 686-690 .
18.
Litwak P , Butler KC , Thomas DCet al.Development and initial testing of a pediatric centrifugal blood pump . Ann Thorac Surg1996; 61: 448-451 .
19.
Noon GP , Ball JW, Jr , Short HD.Bio-Medicus centrifugal ventricular support for postcardiotomy cardiac failure: a review of 129 cases . Ann Thorac Surg1996; 61: 291-295 .
20.
Nakazawa T , Takami Y , Makinouchi Ket al.Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass . Artif Organs1997; 21: 782-785 .
21.
Nishimura K , Yamada T , Kono Set al.Magnetically suspended centrifugal pump as an implantable ventricular assist system. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 391-395.
22.
Nojiri C , Kijima T , Maekawa Jet al.More than 1 year continuous operation of a centrifugal pump with a magnetically suspended impeller . ASAIO J1997; 43: M548-M552 .
23.
Monties J-RE , Trinkl J , Mesana T , Havlik PJ , Demunck J-LY.Cora valveless pulsatile rotary pump: new design and control . Ann Thorac Surg1996; 61: 463-468 .
24.
Golding LAR , Smith WA.Cleveland clinic roto-dynamic pump . Ann Thorac Surg1996; 61: 457-462 .
25.
Hetzer R , Loebe M , Potapov EVet al.Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children . Ann Thorac Surg1998; 66: 1498-1506 .
26.
Weyand M , Kececioglu D , Kehl HGet al.Neonatal mechanical bridging to total orthotopic heart transplantation . Ann Thorac Surg1998; 66: 519-522 .
27.
Takano H , Nakatani T.Ventricular assist systems: experience in Japan with Toyobo pump and Zeon pump . Ann Thorac Surg1996; 61: 317-322 .
28.
Deleuze PH , Le Besnerais P , Mazzucotelli J-Pet al.Use of the Nippon-Zeon pneumatic ventricular assist device as a bridge to cardiac transplantation . ASAIO J1994; 40: M325-M328 .
29.
Daily BB , Pettitt TW , Sutera SP , Pierce WS.Pierce-Donachy pediatric VAD: progress in development . Ann Thorac Surg1996; 61: 437-443 .
30.
Jett GK.ABIOMED BVS 5000: experience and potential advantages . Ann Thorac Surg1996; 1: 301-304 .
31.
Korfer R , El-Banayosy A , Posival Het al.Mechanical circulatory support: the Bad Oeynhausen experience . Ann Thorac Surg1995; 592 Suppl: S56-S63 .
32.
Chen JM , Levin HR , Rose EAet al.Experience with right ventricular assist devices for perioperative right-sided circulatory failure . Ann Thorac Surg1996; 61: 305-310 .
33.
Korfer R , El-Banayosy A , Posival Het al.Mechanical circulatory support with the Thoratec assisted device in patients with postcardiotomy cardiogenic shock . Ann Thorac Surg1996; 61: 314-316 .
34.
Reinhartz O , Farrar DJ , Hershon JH , Avery GJ Jr , Haeusslein EA , Hill JD.Importance of preoperative liver function as a predictor of survival in patients supported with Thoratec ventricular assist devices as a bridge to transplantation . J Thorac Cardiovasc Surg1998; 116: 633-640 .
35.
Farrar DJ , Buck KE , Coulter JH , Kupa EJ.Portable pneumatic biventricular driver for the Thoratec ventricular assist device . ASAIO J1997; 43: M631-M634 .
36.
Imanshi K , Imachi K , Yoshito Het al.Evaluation of a transaortic pulsatile left ventricular assist device (Heart Ranger) [Abstract] . Artif Organs1999; 23: 619-619 .
Frazier OH , Rose EA , McCarthy Pet al.Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system . Ann Surg1995; 222: 327-338 .
Poirier VL.The HeartMate left ventricular assist system: looking into the future. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 163-171.
41.
Frazier OH.Evolution of battery-powered, vented left ventricular assist devices . Ann Thorac Surg1996; 61: 393-395 .
42.
McCarthy PM , Schmitt SK , Vargo RL , Gordon S , Keys TF , Hobbs RE.Implantable LVAD infections: implications for permanent use of the device . Ann Thorac Surg1996; 61: 359-365 .
43.
Müller J , Wallukat G , Weng YGet al.Weaning from mechanical cardiac support in patients with idioathic dilated cardiomyopathy . Circulation1997; 96: 542-549 .
44.
Frazier OH , Benedict CR , Radovancevic Bet al.Improved left ventricular function after chronic left ventricular unloading . Ann Thorac Surg1996; 62: 675-682 .
45.
McCarthy PM , Savage RM , Fraser CDet al.Hemodynamic and physiologic changes during support with an implantable left ventricular assist device . J Thorac Cardiovasc Surg1995; 109: 409-418 .
46.
Rose EA , Goldstein DJ.Wearable long-term mechanical support for patients with end-stage heart disease: a tenable goal . Ann Thorac Surg1996; 61: 399-402 .
47.
Granfeldt H , Solem J-O , Lonn Uet al.The Linkoping-Lund surgical experience with the HeartMate left ventricular assist system . Ann Thorac Surg1995; 592 Suppl: S52-S55 .
48.
Portner PM , Baumgartner WA.Internal pulsatile circulatory support . Ann Thorac Surg1993; 55: 261-265 .
49.
Frazier OH.Chronic left ventricular support with a vented electric assist device . Ann Thorac Surg1993; 55: 273-275 .
50.
Honda N , Inamoto T , Nogawa M , Takatani S.Ultracompact, completely implantable permanent use electromechanical ventricular assist device and total artificial heart . Artif Organs1999; 23: 253-261 .
51.
Ramasamy N , Jansen P , Wheeldon Det al.Inflow conduit in implantable left ventricular assist device (LVAD): influence on outcomes [Abstract] . Artif Organs1999; 23: 624-624 .
52.
Masai T , Kadoba K , Miyamoto Yet al.Application of wearable Novacor left ventricular assist system for patients with end-stage cardiomyopathy: Osaka experience. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 210-216.
53.
Samuels LE , Kaufman MS , Morris RJ , Brozena SC , Twomey C , Brockman SK.The Novacor left ventricular assist system: lessons learned . J Extra-Corp Technol1997; 29: 132-138 .
54.
Schmid C , Weyand M , Nabavi DGet al.Cerebral and systemic embolization during left ventricular support with the Novacor N100 device . Ann Thorac Surg1998; 65: 1703-1710 .
55.
Moczar M , Houel R , Ginat Met al.Evolution of pseudoneointimal growth in LVAS graft conduits [Abstract] . Artif Organs1999; 23: 621-621 .
56.
Kormos RL , Borovetz HS , Gasior Tet al.Experience with univentricular support in mortally ill cardiac transplant candidates . Ann Thorac Surg1990; 49: 261-272 .
57.
McBride LR , Ruggiero R , Powers KA , Moroney DA , Swartz MT.Right ventricular infarction during left ventricular assist system support . Ann Thorac Surg1998; 65: 839-841 .
58.
Winowich S , Nastala CJ , Pristas JM , Griffith BP , Kormos RL.Discharging patients who are undergoing mechanical circulatory support . Ann Thorac Surg1996; 61: 478-479 .
59.
Hachida M , Satoshi S , Kihara Set al.First experience of Novacor implant at the Heart Institute of Japan. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 206-209.
60.
Loisance DY , Deleuze PH , Mazzucotelli J-P , Le Besnerais P , Dubois-Rande J-L.Clinical implantation of the wearable Baxter Novacor ventricular assist system . Ann Thorac Surg1994; 58: 551-554 .
61.
Pennington DG.Extended support with permanent systems: percutaneous versus totally implantable . Ann Thorac Surg1996; 61: 403-406 .
62.
Forster F , Kaufman R , Reul H , Rau G.A small pulsatile blood pump for ventricular support during end-stage heart failure . Artif Organs2000; 24: 373-376 .
63.
Mussivand T , Hum A , Holmes KSet al.Remote monitoring and control of artificial hearts and assist devices. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 370-373.
64.
Mussivand T , Hendry PJ , Masters RJ , Keon WJ , King M , Holmes K.Progress with the HeartSaver ventricular assist device . Ann Thorac Surg1999; 68: 785-789 .
65.
Jarvik R , Westaby S , Katsumata T , Pigott D , Evans RD.LVAD power delivery: a percutaneous approach to avoid infection . Ann Thorac Surg1998; 65: 470-473 .
66.
Tagusari O , Yamazaki K , Litwak Pet al.Fine trabecularized carbon: ideal material and texture for percutaneous device system of permanent left ventricular assist device . Artif Organs1998; 22: 481-487 .
67.
Isoyama T , Abe Y , Chinzei Tet al.An implantable centrifugal pump using transcutaneous magnet coupling between pump head and motor unit [Abstract] . Artif Organs1999; 23: 677-677 .
68.
Nishida H , Uesugi H , Nishinaka Tet al.Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump . Artif Organs1997; 21: 816-821 .
69.
Konishi H , Misawa Y , Antaki JFet al.A new index for characterizing pulsatility: recovery of renal function. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 323-328.
70.
Nose Y , Kawahito K , Nakazawa T.Can we develop a nonpulsatile permanent rotary blood pump? Yes, we can . Artif Organs1996; 20: 467-474 .
71.
Kono S , Nishimura K , Yamada Tet al.In vivo and in vitro evaluation of the pulsatile mode of a magnetically suspended centrifugal pump . ASAIO J1997; 3: M580-M584 .
72.
McCarthy PM.HeartMate implantable left ventricular assist device: bridge to transplantation and future applications . Ann Thorac Surg1995; 592 Suppl: S46-S51 .
73.
Schmid C , Deng M , Hammel D , Weyand M , Loick HM , Scheld HH.Emergency versus elective/urgent left ventricular assist device implantation . J Heart Lung Transplant1998; 17: 1024-1028 .
74.
Loisance DY , Pouillart F , Benvenuti Cet al.Mechanical bridge to transplantation: when is too early? When is too late ? Ann Thorac Surg1996; 61: 388-390 .
75.
Mussivand T , Hendry PJ , Masters RGet al.Development of a totally implantable intrathoracic ventricular assist device. In: Akutsu T , Koyanagi H , eds. Heart Replacement. Artificial Heart 6. Tokyo: Springer , 1998: 1520-1520.
76.
Takiura K , Masuzawa T , Endo Set al.Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests . Artif Organs1998; 22: 393-398 .
77.
Ohara Y , Murase M , Nose Y.Hemolytic effect of the secondary vane incorporated into the backside of the impeller . Artif Organs1997; 21: 694-699 .
78.
Nishida M , Yamane T , Orita T , Asztalos B , Clarke H.Quantitative visualization of flow through a centrifugal blood pump: effect of washout holes . Artif Organs1997; 21: 720-729 .
79.
Nishida M , Yamane T , Asztalos B.Washout hole flow measurement for the development of a centrifugal blood pump . Artif Organs1998; 22: 386-392 .
80.
Joyce LD , Kiser JC , Eales F , King RM , Overton JW Jr , Toninato CJ.Experience with generally accepted centrifugal pumps: personal and collective experience . Ann Thorac Surg1996; 61: 287-290 .
81.
Pavie A , Leger P.Physiology of univentricular versus biventricular support . Ann Thorac Surg1996; 61: 347-349 .
82.
Martin J , Sarai K , Schindler M , van de Loo A , Yoshitake M , Beyersdorf F.MEDOS HIA-VAD biventricular assist device for bridge to recovery in fulminant myocarditis . Ann Thorac Surg1997; 63: 1145-1146 .
83.
Addonizio VP.Insights into thromboembolism and bleeding . Ann Thorac Surg1996; 61: 374-375 .
84.
Griffith BP , Kormos RL , Nastala CJ , Winowich S , Pristas JM.Results of extended bridge to transplantation: window into the future of permanent ventricular assist devices . Ann Thorac Surg1996; 61: 396-398 .
85.
Garrido P , Canizo F , Antoranz J.In vitro characterisation and comparison of ventricular assist devices [Abstract] . Artif Organs1999; 23: 618-618 .
86.
Tagusari O , Kawai A , Yamazaki Ket al.What will happen to permanent left ventricular assist device recipients? Clues from long-term outcomes of heterotopic heart transplants. In: Akutsu T , Koyanagi H , eds. Heart replacement. Artificial heart 6. Tokyo: Springer , 1998: 95-100.