Background
Subclavian venous occlusion sometimes precludes the ability to insert leads during placement of a cardiac implantable electronic device. This study was performed to identify the risk factors for spontaneous subclavian venous occlusion prior to placement of an implantable electronic device.
Methods
We studied 446 patients who underwent axillary-subclavian venography to assess for occlusion and/or anomaly of the subclavian vein or associated veins before electronic device implantation.
Results
Six (1.3%) patients had venous occlusion (left subclavian vein in 5, left innominate vein in 1). There was a significantly higher incidence of previous cancer in the occlusion group than in the nonocclusion group (11.5% vs. 50%, p = 0.03).
Conclusions
Subclavian venous occlusion may be present before cardiac implantable electronic device placement. A history of cancer represents a risk factor subclavian venous occlusion, and patients with this risk factor should undergo subclavian venography prior to electronic device placement.