Abstract
Background
Various techniques have been described for preserving pulmonary valve function in tetralogy of Fallot repair. In selected substrates, the pulmonary valve can be bicuspidized and preserved using polytetrafluoroethylene pericardial membrane.
Methods
This study was a retrospective review of 20 patients aged 11 months to 31 years with tetralogy of Fallot and a bicuspid pulmonary valve (with anteroposterior cusps) who underwent intracardiac repair from August 2010 to January 2013. The anterior cusp was augmented using polytetrafluoroethylene pericardial membrane to preserve the valve hinge. A transannular patch was used in all cases. Data relating to surgical outcome, intensive care unit course, pulmonary regurgitation, and right ventricular outflow tract gradient were collected.
Results
There was no mortality. Predischarge pulmonary regurgitation was ≤grade 2 in 18 (90%) patients. One patient had an outflow gradient >40 mm Hg. On follow-up of 3–24 months, there was no increase in outflow gradient; 18.7% had progression of pulmonary regurgitation.
Conclusion
In selected substrates, this technique is associated with minimization of pulmonary regurgitation and an excellent functional outcome. The utility of this technique needs to be validated over a longer time scale in a larger series.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.