A technique for anatomical positioning of a synthetic aortoaxillary bypass tube graft is described. A tunnel is created with the help of a Roberts clamp and intercostal tube drain. There is no need to open the pleura because the graft is tunneled parallel to the subclavian vessels outside the chest cavity.
ChungJWKimHCChoiYHKimSJLeeWParkJH. Patterns of aortic involvement in Takayasu arteritis and its clinical implications: evaluation with spiral computed tomography angiography. J Vasc Surg2007; 45: 906–14.
2.
MwipatayiBPJefferyPCBeningfieldSJMatleyPJNaidooNGKallaAA. Takayasu arteritis: clinical features and management: report of 272 cases. ANZ J Surg2005; 75: 110–7.
3.
ParkJHHanMCKimSHOhBHParkYBSeoJD. Takayasu arteritis: angiographic findings and results of angioplasty. AJR Am J Roentgenol1989; 153: 1069–74.
4.
ParkJHChungJWLeeKWParkYBHanMC. CT angiography of Takayasu arteritis: comparison with conventional angiography. J Vasc Interv Radiol1997; 8: 393–400.
5.