Although graft replacement for chronic type B dissection is the standard operation, this operation is invasive to some extent, and the mortality and morbidity remain high. We describe a simple and less invasive technique using initial entry closure and aortic tailoring of the dissected lumen.
Get full access to this article
View all access options for this article.
References
1.
SafiHJMillerCC3rdReardonMJIliopoulosDCLetsouGVEspadaR. Operation for acute and chronic aortic dissection: recent outcome with regard to neurologic deficit and early death. Ann Thorac Surg1998; 66: 402–11.
2.
DakeMDKatoNMitchellRSSembaCPRazaviMKShimonoT. Endovascular stent-graft placement for the treatment of acute aortic dissection. N Engl J Med1999; 340: 1585–6.
3.
StoneCDGreenePSGottVLFrankSWilliamsGM. Single-stage repair of distal aortic arch and thoracoabdominal dissecting aneurysms using aortic tailoring and circulatory arrest. Ann Thorac Surg1994; 57: 580–7.