A simple technique termed “clamp test and spinal cord-plegia” for descending thoracic aortic aneurysm surgery is described. The clamp test is a passive method of creating ischemic conditions, whereas spinal cord-plegia is an active method of decreasing metabolism. This technique is a practical test that double-checks for critical feeding arteries and seems to have an excellent spinal cord-preserving effect.
Get full access to this article
View all access options for this article.
References
1.
ReuterDGTackerWAJrBadylakSFVoorheesWD3rdKonradPE. Correlation of motor-evoked potential response to ischemic spinal cord damage. J Thorac Cardiovasc Surg1992;104:262–72.
2.
MeylaertsSADe HaanPKalkmanCJLipsJDe MolBAJacobsMJ. The influence of regional spinal cord hypothermia on transcranial myogenic motor-evoked potential monitoring and the efficacy of spinal cord ischemia detection. J Thorac Cardiovasc Surg1999;118:1038–45.
3.
MeylaertsSADe HaanPKalkmanCJJaspersJVanickyIJacobsMJ. Prevention of paraplegia in pigs by selective segmental artery perfusion during aortic cross-clamping. J Vasc Surg2000;32:160–70.
4.
AllenBTDavisCGOsborneDKarlI. Spinal cord ischemia and reperfusion metabolism: The effect of hypothermia. J Vasc Surg1994;19:332–40.
5.
OkadaKSuedaTShikataHOrihashiKMoritaSHiraiS. Evoked spinal cord potential monitoring reveals peroneal nerve ischemia during thoracoabdominal repair: A case report. Ann Thorac Cardiovasc Surg1999;5:350–2.
6.
SuedaTMoritaSOkadaKOrihashiKShikataHMatsuuraY. Selective intercostal arterial perfusion during thoracoabdominal aortic aneurysm surgery. Ann Thorac Surg2000;70:44–7.