A modification of the Nicks procedure to obtain a firm blood-tight aortoplasty is described. Autologous pericardium was used in a bilayer arrangement with a sandwich suture technique. It was found to be an easy and effective way of decreasing bleeding. It may also prevent true and false aneurysms.
Get full access to this article
View all access options for this article.
References
1.
SchulteHDBircksWFrenzelHHorstkotteDJungblutRMOubariM. Patch-graft enlargement of the aortic root using autologous pericardium (long-term results). Thorac Cardiovasc Surg1983;31: 219–23.
2.
PiehlerJMDanielsonGKPluthJROrszulakTAPugaFJSchaffHV. Enlargement of the aortic root or anulus with autogenous pericardial patch during aortic valve replacement. Long-term follow-up. J Thorac Cardiovasc Surg1983;86: 350–8.
3.
DalichauHHannekumANiehuesBIrionAHerseB. Hemodynamic and angiographic late results following enlargement of narrow aortic root using autologous pericardium in prosthetic aortic valve replacement. Thorac Cardiovasc Surg1985;33: 288–95.
4.
NicksRCartmillTBernsteinL. Hypoplasia of the aortic root. The problem of aortic valve replacement. Thorax1970;25: 339–46.
5.
GirardotJMGirardotMN. Amide cross-linking: An alternative to glutaraldehyde fixation. J Heart Valve Dis1996;5: 518–25.