The coronavirus 2019 pandemic has increased the use of powered air-purifying respirator (PAPR) devices, which produce appreciable noise levels during filtration. Our objective was to determine if active PAPR usage significantly impairs auditory communication in health care providers. We additionally sought to assess what volume of speech presentation was required for adequate communication with providers wearing a PAPR. In subjects with normal hearing at baseline, audiometric data demonstrated a 93% (95% CI, 86%-99%) decrease in word recognition scores during active PAPR usage. Presentation at 85 to 90 dB was needed to obtain word recognition scores similar to baseline in subjects with normal hearing without a PAPR. Pure tone averages also significantly decreased with PAPR usage, by 54 dB (95% CI, 46-62). Active PAPR usage has a substantial impact on auditory perception when utilized by health care providers. The potential longer-term effect of these devices on providers with regular active usage is of interest for future study.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.