Abstract
Objective
To determine and compare the bending moduli of native and engineered human septal cartilage.
Study Design
Prospective, basic science.
Setting
Research laboratory.
Subjects and Methods
Neocartilage constructs were fabricated from expanded human septal chondrocytes cultured in differentiation medium for 10 weeks. Constructs (n = 10) and native septal cartilage (n = 5) were tested in a 3-point bending apparatus, and the bending moduli were calculated using Euler-Bernoulli beam theory.
Results
All samples were tested successfully and returned to their initial shape after unloading. The bending modulus of engineered constructs (0.32 ± 0.25 MPa, mean ± SD) was 16% of that of native septal cartilage (1.97 ± 1.25 MPa).
Conclusion
Human septal constructs, fabricated from cultured human septal chondrocytes, are more compliant in bending than native human septal tissue. The bending modulus of engineered septal cartilage can be measured, and this modulus provides a useful measure of construct rigidity while undergoing maturation relative to native tissue.