This paper deals with the problem of optimizing the lateral resolution with respect to the velocity distribution of the transducer surface. In order to determine the acoustic field, the transducer is divided into circular annuli with a predetermined shape of the velocity distribution. The acoustic field from the transducer is a weighted sum of the fields from the annuli. The lateral resolution is optimized with respect to these weights. Examples are given to illustrate the method.
StepanishenP.R., Acoustic transients from planar axisymmetric vibrators using the impulse response approach, J. Acoust. Soc. Amer.40, 1176–1181 (1981).
2.
SalomonssonG.ManderssonB., On ultrasound transducers with curved surface for improvement of the lateral resolution, IEEE Trans. Ultrason. Ferroelectrics Freq. Contr., UFFC-33, 6, 740–746 (1986).
3.
PierceA.D., Acoustics: An Introduction to its Physical Principles and Applications, (McGraw Hill, New York, 1981).
4.
VerhoefW.A.CloostermansM.H.T.M.ThijssenJ.M., The impulse response of a focused source with an arbitrary axisymmetric surface velocity distribution, J. Acoust. Soc. Amer.75, 1716–1721 (1984).
5.
ManderssonB.SalomonssonG., Weighted least squares pulse shaping filters with application to ultrasonic signals, IEEE Trans. Ultrason. Ferroelectrics Freq. Cont. (Submitted).
6.
BörjessonP-O.HolmerN.G.LindströmK.ManderssonB.SalomonssonG., Digital Preshaping of Ultrasonic Signals; Equipment and Applications, (in IEEE Ultrason. Symp., 696–699 (IEEE Cat. No. 82CH1823-4, 1982)).
7.
LuenbergerP.G., Linear and Nonlinear Programming, (Addison - Wesley, New York, 1984).
8.
FletcherR.PowellM.Y.D., A rapidly convergent descent method for minimization, Computer6, 163–168, (1963).