Percutaneously inserted Silastic central venous catheters have been used for prolonged infusion of parenteral nutrition in neonates. Malassezia furfur infection has been associated with intravenous fat emulsions infused through central venous lines. In this paper, we report two premature infants whose Silastic catheters were adhered to the vein wall with associated M furfur infection. (Journal of Parenteral and Enternal Nutrition 17:458-460, 1993)
Get full access to this article
View all access options for this article.
References
1.
Dolcourt JL, Bose CL: Percutaneous insertion of Silastic central venous catheters in newborn infants . Pediatrics70:484-486, 1982
2.
Loeff DS, Matlak ME, Black RE, et al: Insertion of a small central venous catheter in neonates and young infants. J Pediatr Surg17:944-949, 1982
3.
Durand M., Ramanathan R., Martinelli B., et al: Prospective evaluation of percutaneous central venous Silastic catheters in newborn infants with birth weights of 510 to 3920 grams. Pediatrics78 :245-250, 1986
4.
Powell DA, Aungst J., Snedden S., et al: Broviac catheter-related Malassezia furfur sepsis in five infants receiving intravenous fat emulsions. J Pediatr105:987-990, 1984
5.
Long JG, Keyserling HL: Catheter-related infection in infants due to an unusual lipophilic yeast-Malassezia furfur. Pediatrics76:896-900, 1985
6.
Dankner WM, Spector SA, Fierer J., et al: Malassezia fungemia in neonates and adults: Complication of hyperalimentation. Rev Infect Dis9:743-753, 1987
7.
Shek YH, Tucker MC, Viciana AL, et al: Malassezia furfur-disseminated infection in premature infants . Am J Clin Pathol92 :595-603, 1989
8.
Richet HM, McNeil MM, Edwards MC, et al: Cluster of Malassezia furfur pulmonary infections in infants in a neonatal intensive care unit. J Clin Microbiol27:1197-1200, 1989
9.
Weiss SJ, Schoch PE, Cunha BA: Malassezia furfur fungemia associated with central venous catheter lipid emulsion infusion. Heart Lung20:87-90, 1991
10.
Hruszkewycz V., Holtrop PC, Batton DG, et al: Complications associated with central venous catheters inserted in critically ill neonates . Infect Control Hosp Epidemiol12:544-548, 1991
11.
Azimi PH, Levernier K., Lefrak LM, et al: Malassezia furfur: A cause of occlusion of percutaneous central venous catheters in infants in the intensive care nursery. Pediatr Infect Dis J7:100-103, 1988
12.
Gladman G., Sinha S., Sims DG, et al: Staphylococcus epidermidis and retention of neonatal percutaneous central venous catheters. Arch Dis Child65:234-235, 1990
13.
Goldblum RM , Pelley RP, O'Donnell A., et al: Antibodies to silicone elastomers and reactions to ventriculoperitoneal shunts. Lancet340:510-513, 1992.