Official dissolution methods should always be tried first. If these do not work, however, an alternative method should be accepted. In choosing a method, the physiological relevance should be the prime consideration. Some commonly used dissolution apparatus and physiologically relevant dissolution media for immediate-release tablets and gelatin capsules will be discussed.
El-AriniSKShunGKSkellyJP. Theophylline controlled-release preparations and fatty food: An in vitro study using the rotating dialysis cell method. Pharm Res.1990;7:1134–1140.
4.
NguyenHTShiuGKWorsleyWHSkellyJP. Dissolution of norethindrone-ethinyl estradiol, norethindrone-mestranol and norethindrone acetate-ethinyl estradiol combination tablets. J Pharm Sci.1990;79: 163–167.
5.
WangJTSundaresanGMWorsleyWHShiuGK. Dissolution testing of norethindrone acetate-ethinyl estradiol and norethindrone-mestranol combination tablets. Pharm Res.1993;10(10):s-37.
6.
MeyerMCStraughnABJarviEJWoodGCPelsorFRShahVP. The bioequivalence of carbamazepine tablets with a history of clinical failures. Pharm Res.1992;9:1612–1616.