Abstract
Phenotypic responses of rat calvarial osteoblast-like cells (RCOB) were evaluated on commercially pure titanium (cpTi) surfaces when cultured at high density (5100 cells/mm2). These surfaces were prepared to three different clinically relevant surface preparations (1-μm, 600-grit, and 50-μm-grit sand-blast), followed by sterilization with either ultraviolet light, ethylene oxide, argon plasma-cleaning, or routine clinical autoclaving. Osteocalcin and alkaline phosphatase, but not collagen expression, were significantly affected by surface roughness when these surfaces were altered by argon plasma-cleaning. In general, plasma-cleaned cpTi surfaces demonstrated an inverse relationship between surface roughness and phenotypic markers for a bone-like response. On a per-cell basis, levels of the bone-specific protein, osteocalcin, and the enzymatic activity of alkaline phosphatase were highest on the smooth 1-μm polished surface and lowest on the roughest surfaces for the plasma-cleaned cpTi. Detectable bone cell expression can be altered by clinically relevant surfaces prepared by standard dental implant preparation techniques.