The modulus of elasticity of stainless steel orthodontic wires was found to be 20% below the normally assumed range of 19.3 to 20.0 X 104 MPa (28.0 to 29.0 × 106 psi). Use of the latter value can result in significant computational errors in orthodontic applicance mechanics. The lower modulus was attributed to severe cold drawing.
Get full access to this article
View all access options for this article.
References
1.
Koenig, H.A. , and Burstone, C.J.: Analysis of Generalized Curved Beams for Orthodontic Application, J Biomech7:429-435, 1974.
2.
Defranco, J.C. ; Koenig, H.A. ; and Burstone, C.J. : Three-Dimensional Large Displacement Analysis of Orthodontic Appliances, Submitted for publication.
3.
Yang, T.Y., and Baldwin, J.J.: Analysis of Space Closing Springs in Orthodontics, J Biomech7:21-28, 1974.
4.
Thurow, R.C. : Edgewise Mechanics, 2nd ed, St. Louis: C. V. Mosby Co. , 1966 , pp 51-53.
5.
Metals Handbook, Vol. 1 : Properties and Selection of Metals, 8th ed., Metals Park, Ohio: American Soc. for Metals, 1975, pp. 408-432.