Ozone and glycol vapor were evaluated for effectiveness in the decontamination of air in a closed room. At ozone concentrations of 1.0 ppm (toxic dose for humans and animals), more than 90% of Streptococcus mitis and Staphylococcus epidermidis was removed from the air within five minutes. No airborne reductions were noted at the threshold limit value concentration of ozone (0.1 ppm). Two glycol aerosols did not affect 60-minute reductions in the number of bacteria.
Get full access to this article
View all access options for this article.
References
1.
Coblentz, W.W. : Ultraviolet Radiation and Ozone as Aerial Disinfectants , Arch Phys Ther13:709-711, 1942.
2.
Elford, W.J. , and Van Den Ende, J. : An Investigation of the Merits of Ozone as an Aerial Disinfectant, J Hyg (Camb) 42 : 240-265, 1942.
3.
Greenberg, L. : Effect of Germicidal Aerosol Treatment on the Microbial Flora of Laboratory Air, J Pharm Sci55: 740-742, 1966.
4.
Puck, T.T.; Robertson, O.H.; and Lemon, H.M.: Bactericidal Action of Propylene Glycol on Microorganisms Suspended in the Air, II., J Exp Med78: 387-406, 1948.
5.
Robertson, O.H. ; Bigg, E.; Miller , B.F.; Baker, Z.; and Puck, T.T.: Sterilization of the Air by Certain Glycols Employed as Aerosols, Science93: 213-214, 1941.
6.
Robertson, O.H. ; Bigg, E.; Puck , T.T.; and Miller, B.F.: The Bactericidal Action of Propylene Glycol Vapor on Microorganisms Suspended in the Air, I ., J Exp Med75: 593-610, 1942.
7.
Lester, W., JR.; Kaye, S.; Robertson, O.H.; and Dunklin, E.W.: Factors of Importance in Use of Triethylene Glycol Vapor for Aerial Disinfection , Am J Public Health40: 813-820, 1950.
8.
Cathcart, W.H. ; Ryberg, R.E.; and Merz, A.: I. The Effect of Ultra-violet Radiation and Ozone on Bakery Custard and Cream Fillings, Food Res7: 1-9, 1942.
9.
American Conference of Governmental Industrial Hygienists, Threshold Limit Values for Substance in Workroom Air Adopted by ACGIH for 1972, p 23.
10.
Stokinger, H.E.: Ozone Toxicology, Arch Environ Health10: 719-731, 1965.
11.
Robertson, O.H.; Loosle, C.G.; Puck , T.T.; Lemon, H.M.; Wise, H.; and Lester, W., JR.: Test for Chronic Toxicity of Propylene Glycol and Triethylene Glycol on Monkeys and Rats by Vapor Inhalation and Oral Administration, J Pharmacol Exp Ther91: 52-76, 1947.
12.
Hamburger, M., JR.; Puck, T.T.; and Robertson , O.H.: The Effect of Triethylene Glycol Vapor on Air-borne Beta Hemolytic Streptococci in Hospital Wards, I. J Infect Dis75: 208-215, 1945.
13.
Harris, T.N. , and Stokes, J., JR.: Summary of a 3-year Study of the Clinical Application of the Disinfection of Air by Glycol Vapors, Am J Med Sci209: 152-156, 1945.
14.
Personnel of United States Naval Medical Research Unit No. 4.The Use of Triethylene Glycol Vapor for Control of Acute Respiratory Diseases in Navy Recruits, II. Effect on Acute Respiratory Diseases, Am J Hyg55: 215-229, 1952.
15.
Shreve, W.B. , and Wachtel, L.W.: Effect of Extraneous Particulate Matter on Airborne Bacteria, J Dent Res49: 589-592, 1970.
16.
Bond, R.G.; Halbert, M.M.; Keenan, K.M.; Putnam, H.D.; Ruschmeyer, O.R.; and Vesley, D.: Excerpts from Development of a Method for Microbial Sampling of Surfaces with Special Reference to Reliability. University Health Service and School of Public Health, University of Minnesota, Minneapolis, Minn, July 1963.
17.
Langmuir, A.D. : Epidemiology of Airborne Infection, in McDermott, W. (ed) : Conference on Airborne Infection, Baltimore: Williams & Wilkins Co., 1960.
18.
Miller, L.F. : Acute Respiratory Infections in Naval Personnel, Proceedings of the First International Symposium of Aerobiology, Berkeley, Calif: 1968, pp 3-23.
19.
Williams, R.E.O. : Spread of Airborne Bacteria Pathogenic for Man, 17th Symposium of the Society for General Microbiology. Airborne Microbes . Cambridge: Cambridge University Press, 1967, pp 268-285.
20.
Hayden, J.L. : A Preliminary Aerobic Bacterial Study of Rebounded Sprays from Utilization of the Air Rotor Handpiece, J Kans State Dent Assoc53: 10-13, 1969.
21.
Mazzarella, M.A., and Flynn, D.D.: Dental Aerosols, in An Introduction to Experimental Aerobiology, New York: Wiley-Interscience, 1969 .
22.
Pelleu, G.B. , JR.; Shreve, W.B.; and Wachtel, L.W.: Reduction of Microbial Concentration in the Air of Dental Operating RoomsI. High Efficiency Particulate Air Filters, J Dent Res49: 315-319, 1970.
23.
Larato, D.C. ; Ruskin, P.F.; and Martin, A.: Effect of an Ultrasonic Scaler on Bacterial Counts in Air, J Periodontol38:550-554, 1967.
24.
The Effect of Ozone on Materials, in Air Quality Criteria for Photochemical Oxidants, National Air Pollution Control Administration Publication No. AP-63 . Washington: US Department of Health, Education, and Welfare, 1970.
25.
Pelleu, G.B. , JR., and Wachtel , L.W.: Dental Equipment May Spread Microorganisms, J Environ Health33: 371-375, 1971.