Fifteen commercially available surgical masks were evaluated for efficacy in protecting dental personnel from bacterial aerosols generated from a patient's mouth. The filtering efficiency of masks tested varied from 14 to 99%. Two masks tested under wearing conditions showed no significant marginal leakage. The use of all masks evaluated is subject to several important limitations.
Get full access to this article
View all access options for this article.
References
1.
Micik, R.E.; Miller, R.L.; Mazzarella, M.A.; and Ryge, G.: Studies on Dental Aerobiology: I. Bacterial Aeorosols Generated During Dental Procedures, J Dent Res48:49-59, 1969.
2.
Miller, R.L. ; Micik, R.E.; Able, C.; and Ryge, G.: Studies on Dental Aerobiology: II. Microbial Splatter Discharged from the Oral Cavity of Dental Patients, J Dent Res50:621-625, 1971.
3.
Rockwood, C.A. , and O'Donoghue , M.D.: The Surgical Mask: Its Development, Usage, and Efficiency, Arch Surg ( Chicago) 80:963-971, 1960.
4.
Greene, V.W. , and Vesley, D.: Method for Evaluating Effectiveness of Surgical Masks, J Bact83:663-667, 1962.
5.
Nicholes, P.S. : Comparative Evaluation of a New Surgical Mask Medium, Surg Gynec Obstet118:579-583, 1964.
6.
Thomas, C.G.A. : Efficiency of Surgical Masks in Use in Hospital Wards, Guy Hosp Rep110:157-167, 1961.
7.
Guyton, H.G. ; Buchanan, L.M.; and Lense, F.T.: Evaluation of Respiratory Protection of Contagion Masks, Appl Microbiol4:141-143, 1956.
8.
Freake, R., and Abbott, L.: Method for Testing Bacteriological Efficiency of Surgical Masks in the Operating Theatre, Lancet1:78-79, 1966.
9.
Ford, C.R.; and Peterson, D.E.: The Efficiency of Surgical Face Masks, Amer J Surg106:954-957, 1963.
10.
Guyron, H., and Decker, H.M.: Respiratory Protection Provided by Five New Contagion Masks, Appl Microbiol11 :66-68, 1963.
11.
Stark, M.; Nicholson, R.J.; and Augs-Berger, H.: Aerosol Hazards and Face Mask Protection, J Calif Dent Assn, 1968.
12.
Bailey, R.; Giglio, P.; Blechman, H.; and Nunez, C.: Effectiveness of Disposable Face Masks in Preventing Cross Contamination During Dental Procedures, J Dent Res47:1062-1065, 1968.
13.
Anderson, A.A. : A New Sampler for the Collection, Sizing, and Enumeration of Viable Airborne Particles, J Bact76 :471-484, 1958.