Abstract
Measurement of interfacial fracture toughness (iFT) is considered a more valid method to assess bonding effectiveness as compared with conventional bond strength testing. Common fracture toughness tests are, however, laborious and require a relatively bulky specimen size. This study aimed to evaluate a new simplified and miniaturized iFT (mini-iFT) test. Four dentin adhesives, representing the main adhesive classes, and 1 glass ionomer cement were applied onto flat dentin. Mini-iFT (1.5 × 2.0 × 16 to 18 mm) and microtensile bond strength (µTBS; 1.5 × 1.5 × 16 to 18 mm) specimens were prepared from the same tooth. For the mini-iFT specimens, a single notch was cut at the adhesive-dentin interface with a 150-µm diamond blade under water cooling; the specimens were loaded until failure in a 4-point bending test setup. Finite element analysis was used to analyze stress distribution during mini-iFT testing. The correlation between the mean mini-iFT and µTBS was examined and found to be significant; a strong positive correlation was found (
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.