Tension-tension axial fatigue tests of a uniavial glass filament-reinforced epoxy were conducted at 295 K and 4 K. The fatigue life was found to be an order of magnitude greater at 4 K than at 295 K. These results are believed to be the first 4 K fatigue data reported for a composite material. Key words: Cryogenics; fatigue, fiber composites: liquid helium; low tem perature tests; mechanical properties.
Get full access to this article
View all access options for this article.
References
1.
R. P. Reed and A. F. Clark , Eds., "Materials Research for Superconducting Machinery ," National Bureau of Standards, Boulder, Colorado, AD 780596 and AD/A 004 586, Nat. Tech. Inf. Serv., Springfield, Virginia ( 1974).
2.
M.B. Kasen, "Mechanical and Thermal Properties of Filamentary-Reinforced Structural Composites at Cryogenic Temperatures-I: Glass-Reinforced Composites", Cryogenics, Vol. 15 (1975 ), p. 230.
3.
C.W. Fowlkes and R.L. Tobler, "Fracture Testing and Results for a Ti-6A1-4V Alloy at Liquid Helium Temperature," to be published, Eng. Fract. Mechs.
4.
M. Segimoto, "Qualification Test Results for Glass Filament-Wound Support Bands ," Report No. 7581, Structural Composites Industries, Inc. , California (Jan. 1975).
5.
K.E. Hofer, Jr., and E.M. Olsen , "An Investigation of Fatigue and Creep Properties of Glass Reinforced Plastics for Primary Aircraft Structures," Report M6104, Ill. Inst. Tech. Res. Inst. (Apr. 1967).
6.
L.J. Broutman, "Fibre-reinforced Plastics," Chap. 13 in Modern Composite Materials, L. J. Broutman and R. H. Krock, Eds., Addison-Wesley, Massachusetts (1967).
7.
R.B. Heywood , Present and Potential Fatigue and Creep Strengths of Reinforced Plastics, Tech. Note. No: Chem.1337, Royal Aircraft Establishment, Ministry of Supply, London, W. C. 2 (Oct. 1958).