A simplified model is used to describe the parallel operating characteristics of self-excited induction generators. Experimental results are presented for two single-phase machines when driven at different speeds, parallel connected to a common excitation capacitor and resistance load.
Get full access to this article
View all access options for this article.
References
1.
GiddensE. P.SpittalW. and WatsonD. B., ‘Small hydro from a submersible pump’, Water Power and Dam Construction, 34, pp. 33–35 (1982).
2.
MilnerI. P. and WatsonD. B., ‘An autonomous wind energy converter using a self excited induction generator for heating purposes’, Wind Engineering, 6, pp. 19–23 (1982).
3.
de MelloF. P. and HannettL. N., ‘Large scale induction generators for power systems’, IEEE Trans. on Power Apparatus and Systems, PAS-100, pp. 2610–2618 (1981).