Existing graphical methods of Walker and Knight and Haddock require the plotting of a limacon and give only one point on the load caharacteristic. A simple adaptation of these is suggested which yields an easy and rapid method of deriving the entire load characteristic from open circuit to short circuit.
Get full access to this article
View all access options for this article.
References
1.
WalkerJ. H.‘Operating characteristics of salient-pole machines’, Proc. IEE, 100(II), pp. 13–24,(1953).
2.
KnightG. J., and HaddockL.‘An original method for predicting the terminal voltage of an alternator for fixed excitation by the two-axis theory’, Int. J. Elect. Enging. Educ., 14(4), pp. 371–79, (1977).
3.
SayM. G., Alternating Current Machines, Pitman, pp. 392–94, (1976).