The use of high frequency ultrasonic Lamb waves to measure the thickness of thin plates and foils, is discussed and the feasibility of their application to the determination of the degree of cure of polymer coating on coated tin plated steel sheet (as used by the food can industry) is evaluated. The paper also discusses briefly the design features of the purpose built precision double probe ultrasonic goniometer used to carry out these measurements.
Get full access to this article
View all access options for this article.
References
1.
ZarsavNDesign, construction and trials of a precision double-probe ultrasonic goniometer.Brunei University1984.
2.
LambHoraceOn waves in an elastic plate. Proc of Royal Society, Vol. 93, PT Series A 1917 pp 114–28.
3.
LeazekFilipczynskiUltrasonic Methods of Testing Materials. Edited by BlitzJLondon. Butterworth1966.
4.
WorltonD CExperimental Confirmation of Lamb Waves at Megacycle FrequenciesJ of App Phy Vol 321961, pp 967–79.