BekemeyerWB, CrapoRO, CalhoonS, CannonCY, ClaytonPD. Efficacy of chest radiography in a respiratory intensive care unit: a prospective study. Chest1985;88(5):691–696.
JanowerML, Jennas-NoceraZ, MukaiJ.Utility and efficacy of portable chest radiographs. AJR Am J Roentgenol1984;142(2):265–267.
4.
MilneEN, PistolesiM, MiniatiM, GiuntiniC.The vascular pedicle of the heart and the vena azygos. Part I: The normal subject. Radiology1985;152(1):1–8.
5.
RoseCP, StolbergHO. The limited utility of the plain chest film in the assessment of left ventricular structure and function. Invest Radiol1982;17(2):139–144.
McHughTJ, ForresterJS, AdlerL, ZionD, SwanHJ. Pulmonary vascular congestion in acute myocardial infarction: hemodynamic and radiologic correlations. Ann Int Med1972;76(1):29–33.
10.
SimonM.The pulmonary vessels: their hemodynamic evaluation using routine radiographs. Radiol Clin N Am1963;2:363–375.
11.
HermanPG, KhanA, KallmanCE, RojasKA, CarmodyDP, BodenheimerMM. Limited correlation of left ventricular end-diastolic pressure with radiographic assessment of pulmonary hemodynamics. Radiology1990;174(3 Pt 1):721–724.
12.
The chest x-ray in acute left ventricular power failure: an aid to determining prognosis of patients supported by intraaortic balloon pumping. AJR Am J Roentgenol1976;126(6):1147–1157.
13.
WoodringJH. Pulmonary artery-bronchus ratios in patients with normal lungs, pulmonary vascular plethora, and congestive heart failure. Radiology1991;179(1):115–122.
14.
BenjaminJJ, CascadePN, RubenfireM, WajszczukW, KerinNZ. Left lower lobe atelectasis and consolidation following cardiac surgery: the effect of topical cooling on the phrenic nerve. Radiology1982;142(1):11–14.
15.
ZylakCJ, LittletonJT, DurizchML. Illusory consolidation of the left lower lobe: a pitfall of portable radiography. Radiology1988;167(3):653–655.
16.
RobertsJ, BarnesW, PennockMH, BrowneG.Diagnostic accuracy of fever as a measure of postoperative pulmonary complications. Heart Lung1988;17(2):166–170.
17.
AndrewsCP, CoalsonJJ, SmithJD, JohansonWGJr. Diagnosis of nosocomial bacterial pneumonia in acute diffuse lung disease. Chest1981;80(3):254–258.
18.
MockCN, BurchardKW, HasanF, ReedM.Surgical intensive care unit pneumonia. Surgery1988;104(3):494–499.
19.
NorwoodSH, CivettaJM. Evaluating sepsis in critically ill patients (review). Chest1987;92(1):137–144.
KuhlmanJE, FishmanEK, TeigenC.Pulmonary septic emboli: diagnosis with CT. Radiology1990;174(1):211–213.
22.
BachofenM, WeibelER. Alterations of the gas exchange apparatus in adult respiratory insufficiency associated with septicemia. Am Rev Respir Dis1977;116(4):589–615.
HolterJF, WeilandJE, PachER, GadekJE, DavisWB. Protein permeability in the adult respiratory distress syndrome: loss of size selectivity of the alveolar epithelium. J Clin Invest1986;78(6):1513–1522.
25.
AlbeldaSM, GefterWB, KelleyMA, EpsteinDM, MillerWT. Ventilator-induced subpleural air cysts: clinical, radiographic and pathologic significance. Am Rev Respir Dis1983;127(3):360–365.
26.
McLoudTC, BarashPG, RavinCE. PEEP: radiographic features and associated complications. AJR Am J Roentgenol1977;129(2):209–213.
27.
EvansRW, ManninenDL, GarrisonLPJr, MaierAM. Donor availability as the primary determinant of the future of heart transplantation. JAMA1986;255(14):1892–1898.
28.
O'ConnellJB, GunnarRM, EvansRW, FrickerFJ, HuntSA, KirklinJK. 24th Bethesda conference: cardiac transplantation. Task I: Organization of heart transplantation in the U.S. J Am Coll Cardiol1993;22(1):8–14.
29.
Committee to evaluate the artificial heart program of the National Heart, Lung and Blood Institute. Clinical effectiveness and need. In: HognessJR, VanAntwerpM, editors. The artificial heart: prototypes, policies and patients. Washington DC: National Academy Press; 1991:75–82.
30.
WechslerRJ, SpirnPW, ConantEF, SteinerRM, NeedlemanL.Thrombosis and infection caused by thoracic venous catheters: pathogenesis and imaging findings (review). AJR Am J Roentgenol1993;160(3):467–471.
31.
ScottWL. Complications associated with central venous catheters: a survey. Chest1988;94(6):1221–1224.
32.
McLoudTC, PutmanCE. Radiology of the Swan-Ganz catheter and associated pulmonary complications. Radiology1975;116(1):19–22.
KarlsonKB, MartinEC, BregmanD, FankuchenEI, CasarellaWJ. Superior mesenteric artery obstruction by intraaortic counterpulsation balloon simulating embolism: a case report. Cardiovasc Intervent Radiol1981;4(4):236–238.
35.
AndersonHL 3rd, DeliusRE, SinardJM, McCurryKR, ShanleyCJ, ChapmanRA, et al. Early experience with adult extracorporeal membrane oxygenation in the modern era. Ann Thorac Surg1992;53(4):553–563.
36.
FrazierOH, RoseEA, MacmanusQ, BurtonNA, LefrakEA, PoirierVL, DasseKA. Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device. Ann Thorac Surg1992;53(6):1080–1090.
37.
RoseEA, LevinHR, OzMC, FrazierOH, MacmanusQ, BurtonNA, LefrakEA. Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimizing thromboembolism. Circulation1994;90(5 Pt 2):1187–1191.
38.
FrazierOH. First use of an untethered, vented electric left ventricular assist device for long-term support. Circulation1994;89(6):2908–2914. Published erratum appears in Circulation 1995;91(12):3026.