PetersonBD. Heated humidifiers: structure and function. Respir Care Clin N Am1998;4(2):243–260.
2.
WalkerAK, BethuneDW. A comparative study of condenser humidifiers. Anaesthesia1976;31(8):1086–1093.
3.
DeryR.The evolution of heat and moisture in the respiratory tract during anaesthesia with a non-rebreathing system. Can Anaesth Soc J1973;20(3):296–309.
4.
IngelstedtS.Studies on conditioning of respired air in the respiratory tract. Acta Otolaryngol1956;131(Suppl):7–21.
5.
DeryR, PelletierJ, JacquesA, ClavetM, HoudeJJ. Humidity in anesthesiology. 3. Heat and moisture patterns in the respiratory tract during anaesthesia with the semi-closed systemCan Anaesth Soc J1967;14(4):287–295.
6.
BurtonJD. Effects of dry anaesthetic gases on the respiratory mucous membrane. Lancet1962;1:235–238.
7.
ChalonJ, LoewDAY, MalebrancheJ.Effects of dry anesthetic gases on tracheobronchial epithelium. Anesthesiology1972;37(3):338–343.
8.
FonkalsrudEW, SanchezM, HigashijimaI, ArimaE.A comparative study of the effects of dry vs. humidified ventilation on canine lungs. Surgery1975;78(3):373–380.
9.
ForbesAR. Humidification and mucus flow in the intubated trachea. Br J Anaesth1973;45(8):874–878.
10.
AARC. Clinical Practice Guideline. Humidification during mechanical ventilation. Respir Care1992;37(8):887–890.
11.
American Association for Respiratory Care. Consensus statement on the essentials of mechanical ventilators. Respir Care1992;37(9):1000–1008.
12.
HessDR, BransonRD. Humidification: humidifiers and nebulizers. In: BransonRD, HessDR, ChatburnRL, editors. Respiratory care equipment. Philadelphia: JB Lippincott; 1995.
13.
MiyaoH, HirokawaT, MiyasakaK, KawazoeT.Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire. Crit Care Med1992;20(5):674–679.
RhameFS, StreifelA, McCombC, BoyleM.Bubbling humidifiers produce microaerosols which can carry bacteria. Infect Control1986;7(8):403–407.
16.
GoularteTA, ManningMT, CravenDE. Bacterial colonization in humidifying cascade reservoirs after 24 and 48 hours of continuous mechanical ventilation. Infect Control1987;8(5):200–203.
17.
ShanksCA. Clinical anesthesia and the multiple-gauze condenser-humidifier. Br J Anaesth1974;46(10):773–777.
18.
MapelsonWW, MorganJG, HillardER. Assessment of condenser humidifiers with special reference to the multiple-gauze model. Br Med J1963;1:300–305.
19.
BransonRD, DavisKJr. Evaluation of 21 passive humidifiers according to the ISO 9360 standard: moisture output, dead space, and flow resistance. Respir Care1996;41(8):736–743.
20.
Medical devices directorate evaluation. Department of Health, Scottish Home and Health Department. Welsh Office and Department of Health and Social Services Northern Ireland.
21.
CigadaM, ElenaA, SolcaM, DamiaG.The efficiency of twelve heat and moisture exchangers: an in vitro evaluation. Intensive Care World1990;7:98–101.
22.
ShellyM, BethuneDW, LatimerRD. A comparison of five heat and moisture exchangers. Anaesthesia1986;41(5):527–532.
23.
WeeksDB, RamseyFM. Laboratory investigation of six artificial noses for use during endotracheal anesthesia. Anesth Analg1983;62(8):758–763.
24.
MebiusC.A comparative evaluation of disposable humidifiers. Acta Anaesthesiol Scand1983;27(5):403–409.
25.
Evaluation report: heat and moisture exchangers. J Med Eng Technol1987;11(3):117–127.
26.
OginoM, KopoticR, ManninoFL. Moisture-conserving efficiency of condenser humidifiers. Anaesthesia1985;40(10):990–995.
27.
Health Devices. Heat and moisture exchangers. 1983;12:155–166.
28.
UnalN, PompeJC, HollandWP, GultunaI, HuygenPE, JabaaijK, et al. An experimental set-up to test heat-moisture exchangers. Intensive Care Med1995;21(2):142–148.
29.
Annual book of ASTM standards: F1690-96 standard specification for humidifiers for medical use. Part 1: general requirements for active humidification systems. Section 13: medical devices and services. Volume 13.01: medical devices; emergency medical services. West Conshohocken PA: American Society for Testing Materials; 1996:1078–1092.
30.
International Organization for Standardization 1992. ISO 9360: anaesthetic and respiratory equipment—heat and moisture exchangers for use in humidifying respired gases in humans. Geneva, Switzerland: International Organization for Standardization; 1992.
31.
BransonRD, CampbellRS, DavisKJr. Effect of expiratory flow on moisture output of passive humidifiers as measured by the ISO 9360 standard. Respir Care1997;42(10):960–964.
32.
PloysongsangY, BransonRD, RashkinMC, HurstJM. Effect of flowrate and duration of use on the pressure drop across six artificial noses. Respir Care1989;34(10):902–907.
33.
NishimuraM, NishijimaMK, OkadaT, TaenakaN, YoshiyaI.Comparison of flow-resistive work load due to humidifying devices. Chest1990;97(3):600–604.
34.
ManthousCA, SchmidtGA. Resistive pressure of a condenser humidifier in mechanically ventilated patients. Crit Care Med1994;22(11):1792–1795.
35.
ChiarandaM, VeronaL, PinamontiO, DominioniL, MinojaG, ContiG.Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance. Intensive Care Med1993;19(8):462–466.
36.
McEwanAl, DowellL, KarisJH. Bilateral tension pneumothorax caused by a blocked bacterial filter in an anesthesia breathing circuit. Anesth Analg1993;76(2):440–442.
37.
LoeserEA. Water-induced resistance in disposable respiratory-circuit bacterial filters. Anesth Analg1978;57(2):269–271.
38.
BuckleyPM. Increase in resistance of in-line breathing filters in humidified air. Br J Anaesth1984;56(6):637–643.
39.
TenaillonA, CholleyG, BoiteauR, Perrin-GachadoatD, BurdinM.Heat and moisture exchanging Bacterial filters versus heated humidifier in long-term mechanical ventilation. Care Crit Ill1991;7:56–66.
40.
PrasadKK, ChenL.Complications related to the use of a heat and moisture exchanger (letter). Anesthesiology1990;72(5):958. Published erratum appears in Anesthesiology 1990;73(2):72.
41.
MartinezFJ, PietchelS, WiseC, WalekJ, BeamisJF. Increased resistance of hygroscopic condenser humidifiers when using a closed circuit suction system. Crit Care Med1994;22(10):1668–1673.
42.
StaceyMR, AsaiT, WilkesA, HodzovicI.Obstruction of a breathing system filter (letter). Can J Anaesth1996;43(12):1276.
43.
SmithCE, OtworthJR, KaluszykP.Bilateral tension pneumothorax due to a defective anesthesia breathing circuit filter. J Clin Anesth1991;3(3):229–234.
44.
KogaY, IwatsukiN, TakahashiM, HashimotoY.A hazardous defect in a humidifier (letter). Anesth Analg1990;71(6):712.
45.
PradosW.A dangerous defect in a heat and moisture exchanger (letter). Anesthesiology1989;71(5):804.
46.
IottiGA, OliveiMC, PaloA, GalbuseraC, VeronesiR, ComelliA, et al. Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients. Intensive Care Med1997;23(4):399–405.
47.
PelosiP, SolcaM, RavagnanI, TubioloD, FerrarioL, GattinoniL.Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure. Crit Care Med1996;24(7):1184–1188.
48.
ContiG, De BlasiRA, RoccoM, PelaiaP, AntonelliM, BufiM, et al. Effects of heat-moisture exchangers on dynamic hyperinflation of mechanically ventilated COPD patients. Intensive Care Med1990;16(7):441–443.
49.
Le BourdellesG, MierL, FiquetB, DjedainiK, SaumonG, CosteF, DreyfussD.Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest1996;110(5):1294–1298.
50.
RathbergerJ, ZielmanS, KietzmanD, ZuchnerK, WarneckeG.[Is the use of lithium chloride coated "Heat and Moisture Exchangers" (artificial noses) dangerous for patients?]Der Anaesthesist1992;41:204–207.
51.
RosiR, BuscalferriA, MonfregolaMR, CrisuoloS, Dal PraP, StancaA.Systemic lithium reabsorption from lithium-chloride-coated heat and moisture exchangers. Intensive Care Med1995;21(11):937–940.
52.
BransonRD, CampbellRS, DavisKJr, OttawayM, JohannigmanJA. Comparison of a new active heat and moisture exchanger to conventional heated humidification. Respir Care (1999, in press).
53.
BransonRD, CampbellRS, JohannigmanJA, DavisKJr, FrameSB. A comparison of two novel methods of humidification (abstract). Crit Care Med1999;27:A70.
54.
BransonRD, DavisK, CampbellRS, JohnsonDJ, PorembkaDT. Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest1993;104(6):1800–1805.
55.
MartinC, PerrinG, GevaudanMJ, SauxP, GouinF.Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest1990;97(1):144–149.
56.
CohenIL, WeinbergPF, FeinIA, RowiniskiGS. Endotracheal tube occlusion associated with the use of heat moisture exchangers in the intensive care unit. Crit Care Med1988;16(3):277–279.
57.
MissetB, EscudierB, RivaraD, LeclercqB, NitenbergG.Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. Chest1991;100(1):160–163.
58.
RoustanJP, KienlenJ, AubasP, AubasS, du CailarJ.Comparison of hydrophobic heat and moisture exchanger with heated humidifiers during prolonged mechanical ventilation. Intensive Care Med1992;18(2):97–100.
59.
SuzukawaM, UsudaY, NumataK.The effects on sputum characteristics of combining an unheated humidifier with a heat-moisture exchanging filter. Respir Care1989;34(11):976–984.
60.
BeydonL, TongD, JacksonN, DreyfussD.Correlation between simple clinical parameters and the in vitro humidification characteristics of filter heat and moisture exchangers. Groupe de Travail sur les Respirateurs. Chest1997;112(3):739–744.
61.
GallagherI, StrangewaysJE, Allt-GrahamJ.Contamination control in long-term ventilation. A clinical study using a heat- and moisture-exchanging filter. Anaesthesia1987;42(5):476–481.
62.
DjedainiK, BilliardM, MierL, BourdellesG, BrunP, MarkowiczP, et al. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med1995;152(5 Pt 1):1562–1569.
63.
KollefMH, ShapiroSD, BoydV, SilverP, Von HarzB, TrovillionE, PrenticeD.A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest1998;113(3):759–767.
64.
DavisKJr, EvansSL, CampbellRS, JohannigmanJA, LuchetteFA, PorembkaDT, BransonRD. Prolonged use of heat and moisture exchangers does not effect device efficiency or incidence of nosocomial pneumonia. Crit Care Med (1999, in press).
65.
BransonRD, DavisKJr, BrownR, RashkinM.Comparison of three humidification techniques during mechanical ventilation: Patient selection, cost, and infection considerations. Respir Care1996;41(9):809–816.
66.
GrolmanW, BlomED, BransonRD, SchouwenburgPF, HamakerRC. An efficiency comparison of four heat and moisture exchangers used in the laryngectomized patient. Laryngoscope1997;107(6):814–820.
67.
HilgersFJ, AaronsonNK, AckerstaffAH, SchouwenburgPF, van ZandwijkN.The influence of a heat and moisture exchanger (HME) on the respiratory symptoms after total laryngectomy. Clin Otolaryngol1991;16(2):152–156.
68.
AckerstaffAH, HilgersFJ, AaronsonNK, BalmAJ, van ZandwijkN.Improvements in respiratory and psychosocial functioning following total laryngectomy by the use of a heat and moisture exchanger. Ann Otol Rhinol Laryngol1993;102(11):878–883.