al-AliMK, HowarthPH. Nitric oxide and the respiratory system in health and disease (review). Respir Med1998;92(5):701–715.
3.
NIOSH recommendations for occupational safety and health standards, 1988. MMWR Morb Mortal Wkly Rep1988;37(Suppl 7):1–29.
4.
Tentative standard for the classification of toxic gas mixtures. Arlington, VA: Compressed Gas Association; 1991.
5.
AustinAT. The chemistry of the higher oxides of nitrogen as re-lated to the manufacture, storage, and administration of nitrous oxide. Br J Anaesth1967;39(5):345–350.
6.
EvansMJ, StephensRJ, CabralLJ, et al. Cell renewal in the lungs of rats exposed to low levels of NO2. Arch Environ Health1972;24(3):180–188.
7.
KellyFJ, BlombergA, FrewA, HolgateST, SandstromT.Anti-oxidant kinetics in lung lavage fluid following exposure of humans to nitrogen dioxide. Am J Respir Crit Care Med1996;154(6 Pt 1):1700–1706.
8.
KainML. Higher oxides of nitrogen in anesthetic gas circuits. Br J Anaesth1967;39(5):382–387.
9.
Clutton-BrockJ.Two cases of poisoning by contamination of ni-trous oxide with the higher oxides of nitrogen during anaesthesia. Br J Anaesth1967;39(5):388–392.
10.
ShielFO. Morbid anatomical changes in the lungs of dogs after inhalation of higher oxides of nitrogen during anaesthesia. Br J Anaesth1967;39(5):413–424.
11.
HessD, RitzR, BransonRD. Delivery systems for inhaled nitric oxide. Respir Care Clin N Am1997;3(3):371–410.
12.
YoungJD, DyarOJ. Delivery and monitoring of inhaled nitric oxide. Intensive Care Med1996;22(1):77–86.
13.
ZapolWM, HurfordWE. Inhaled nitric oxide in the adult respira-tory distress syndrome and other lung diseases. New Horiz1993;1(4):638–650.
14.
KrebsC, EscuyerM, UrakG, ZimpferM, GermannP.Technolog-ical basis for NO application and environmental security. Acta Anaesthesiol Scand Suppl1996;109:84–87.
15.
WestfeltUN, LundinS, StenqvistO.Nitric oxide administration after the ventilator: evaluation of mixing conditions. Acta Anaes-thesiol Scand1997;41(2):266–273.
16.
WhiteleySM, CohenAT, LaycockD, ArrowsmithWM, HenrysPD. Nitric oxide: description of a pipeline delivery system. Anaes-thesia1997;52(6):561–566.
17.
PinskyMR, GencF, LeeKH, DelgadoE.Contamination of hos-pital air with nitric oxide: unwitting replacement therapy. Chest1997;111(6):1759–1763.
18.
BouchetM, RenaudinMH, RaveauC, MercierJC, DehanM, Zu-panV.Safety requirement for use of inhaled nitric oxide in neo-nates (letter). Lancet1993;341(8850):968–969.
19.
FourbertL, FlemingB, LatimerR, JonasM, OduroA, BorlandC, HigenbottamT.Safety guidelines for use of nitric oxide (letter). Lancet1992;339(8809):1615–1616.
20.
GlassonWA, TuesdayCS. The atmospheric thermal oxidation of nitric oxide. J Am Chem Soc1963;85:2901–2910.
21.
FramptonMW, MorrowPE, CoxC, GibbFR, SpeersDM, UtellMJ. Effects of nitrogen dioxide exposure on pulmonary function and airway reactivity in normal humans. Am Rev Respir Dis1991;143(3):522–527.
22.
NishimuraM, HessD, KacmarekRM, RitzRA, HurfordWE. Nitrogen dioxide production during mechanical ventilation with nitric oxide in adults. Effects of ventilator internal volume, air versus nitrogen dilution, minute ventilation, and inspired oxygen fraction. Anesthesiology1995;82(3):1246–1254.
23.
LowsonSM, RichGF, McArdlePA, JaideuJ, MorrisGN. The response of varying concentrations of inhaled nitric oxide in pa-tients with acute respiratory distress syndrome. Anesth Analg1996;82(5):574–581.
24.
JournoisD, PouardP, MauriatP, MalhereT, VouheP, SafranD.Inhaled nitric oxide as a therapy for pulmonary hypertension after operations for congenital heart defectsJ Thorac Cardiovasc Surg1994;107(4):1129–1135.
25.
StephensRJ, FreemanG, EvansMJ. Early response of lungs to low levels of nitrogen dioxide. Light and electron microscopy. Arch Environ Health1972;24(3):160–179.
26.
OrehekJ, MassariJP, GayrardP, GrimaudC, CharpinJ.Effect of short-term, low-level nitrogen dioxide exposure on bronchial sen-sitivity of asthmatic patients. J Clin Invest1976;57(2):301–307.
27.
HazuchaMJ, FolinsbeeLJ, SealE, BrombergPA. Lung function response of healthy women after sequential exposures to NO, and O. Am J Respir Crit Care Med1994;150(3):642–647.
28.
AidaA, MiyamotoK, SaitoS, NakanoT, NishimuraM, OmoriY, et al. Effects of temperature and humidity on the stability of nitric oxide, and efficiency of soda lime as a selective absorber of nitro-gen dioxide. Nihon Kyobu Shikkan Gakkai Zasshi1995;33(3):306–311. (Article in Japanese.)
29.
KleinmanMT, BaileyRM, LinnWS, AndersonKR, WhynotJD, ShamooDA, HackneyJD. Effect of 0.2 ppm nitrogen dioxide on pulmonary function and response to bronchoprovocation in asth-matics. J Toxicol Environ Health1983;12(4-6):815–826.
30.
SandstromT, StjernbergN, EklundA, LedinMJ, BjermerL, Kol-modin-HedmanB, et al. Inflammatory cell response in bronchoal-veolar lavage fluid after nitrogen dioxide exposure of healthy sub-jects: a dose-response study. Eur Respir J1991;4(3):332–337.
31.
GongHJr. Health effects of air pollution. A review of clinical studies. Clin Chest Med1992;13(2):201–214.
32.
WilliamsRA, RhoadesRA, AdamsWS. The response of lung tissue and surfactant to nitrogen dioxide exposure. Arch Intern Med1971;128(1):101–108.
33.
GreenbaumR, BayJ, HargreavesMD, KainML, KelmanGR, NunnJF, et al. Effects of higher oxides of nitrogen on the anaes-thetized dog. Br J Anaesth1967;39(5):393–404.
34.
FreemanG, CraneSC, FuriosiNJ, StephensRJ, EvansMJ, MooreWD. Covert reduction in ventilatory surface area in rats during prolonged exposure to subacute nitrogen dioxide. Am Rev Respir Dis1972;106(4):563–579.
35.
RasmussenTR, KjaergaardSK, TarpU, PedersenOF. Delayed effects of NO2 exposure on alveolar permeability and gluthione peroxidase in healthy humans. Am Rev Respir Dis1992;146(3):654–659.
36.
MorrowPE, UtellMJ, BauerMA, SmeglinAM, FramptonMW, CoxC, et al. Pulmonary performance of elderly normal subjects and subjects with chronic obstructive pulmonary disease exposed to 0.3 ppm nitrogen dioxide. Am Rev Respir Dis1992;145(2 Pt 1):291–300.
37.
BylinG, HedenstiernaG, LindvallT, SundinB.Ambient nitrogen dioxide concentrations increase bronchial responsiveness in sub-jects with mild asthma. Eur Respir J1988;1(1):606–612.
38.
PostlethwaitEM, LangfordSD, BidaniA.Kinetics of NO2 air space absorption in isolated rat lungs. J Appl Physiol1992;73(5):1939–1945.
39.
LosaM, TibballsJ, CarterB, HoltMP. Generation of nitrogen dioxide during nitric oxide therapy and mechanical ventilation of children with a Servo 900C ventilator. Intensive Care Med1997;23(4):450–455.
40.
DubeL, FrancoeurM, TroncyE, CarrierR, BlaiseG.Comparison of two administration techniques on inhaled nitric oxide on nitrogen dioxide production. Can J Anaesth1995;42(10):922–927.
41.
BreuerJ, WaidelichF, Irtel von BrenndorffCI, SieverdingL, Rosen-dahlW, BadenW, et al. Technical considerations for inhaled nitric oxide therapy: time response to nitric oxide dosing changes and formation of nitrogen dioxide. Eur J Pediatr1997;156(6):460–462.
42.
StenqvistO, KjelltoftR, LundinS.Evaluation of a new system for ventilatory administration of nitric oxide. Acta Anaesthesiol Scand1993;37(7):687–691.
43.
WeimannJ, HagenahU, MotschJ.Reduction in nitrogen dioxide concentration by soda lime preperations during simulated nitric oxide inhalation. Br J Anaesth1997;79(5):641–644.
44.
IshibeT, SatoT, HayashiT, KatoN, HataT.Absorption of nitro-gen dioxide and nitric oxide by soda lime. Br J Anaesth1995;75(3):330–333.
45.
PickettJA, MoorsAH, LatimerRD, MahmoodN, GhoshS, OduroA.The role of soda lime during administration of inhaled nitric oxide. Br J Anaesth1994;72(6):683–685.
46.
PoultonBB, FourbertL, KlinowskiJ, et al. Extraction of nitric oxide from an oxygen carrier using molecular sieve 5A. Br J An-aesth1996;77:534–536.
47.
SquireS, KightleyR, PetrosAJ. An effective method of scavenging nitric oxide. Br J Anaesth1996;77(3):432–434.
48.
DhillonJS, KronickJB, SinghNC, JohnsonCC. A portable nitric oxide scavenging system designed for use on neonatal transport. Crit Care Med1996;24(6):1068–1071.
49.
FrancoM, TroncyE, BlaiseG.Inhaled nitric oxide: technical as-pects of administration and monitoring. Crit Care Med1998;26(4):782–796.
50.
MotschJ, BachA, BohrerH, et al. Reduction in nitric dioxoide formation during nitric oxide inhalation (abstract). Anesthesiology1994;81:A1268.
51.
PickettJA, MahmoodN, LatimerRD, et al. Effective absorption of nitrogen dioxide with soda lime. Br J Anaesth1995;74:107–108.
52.
IshibeY, SatoT.Effective absorption of nitrogen dioxide with soda lime (abstract). Br J Anaesth1995;74:107.
53.
GoldmanAP, CookPD, MacraeDJ. Exposure of intensive-care staff to nitric oxide and nitrogen dioxide (letter). Lancet1995;345(8954):923–924.
54.
FourbertL, MareelsK, LatimerR, et al. Evaluation of soda lime as a nitric oxide and nitrogen dioxide scavenger (abstract). Br J An-aesth1995;74(Suppl II):2(A3).
55.
MourgeonE, LevesqueE, DuveauG, Law-KouneJD, CharbitB, TernissienE, et al. Factors influencing indoor concentrations of nitric oxide in a Parisian intensive care unit. Am J Respir Crit Care Med1997;156(5):1692–1695.
56.
HessD, BigatelloL, KacmarekRM, RitzR, HeadCA, HurfordWE. Use of inhaled nitric oxide in patients with acute respiratory distress syndrome. Respir Care1996;41:424–444.
57.
HessD, KacmarekR, ImanakaH, et al. Administration of inhaled nitric oxide by nasal cannula (abstract). Am J Respir Crit Care Med1995;151:A44.
58.
HessD, KacmarekRM, RitzR, BigatelloLM, HurfordWE. Inhaled nitric oxide delivery systems: a role for respiratory therapists (editorial). Respir Care1995;40(7):702–705.
59.
HessD, BigatelloL, HurfordWE. Toxicity and complications of inhaled nitric oxide. Respir Care Clin N Am1997;3(4):484–503.
60.
KrafftP, FridrichP, FitzgeraldRD, KocD, SteltzerH.Effective-ness of nitric oxide inhalation in septic ARDS. Chest1996;109(2):486–493.
61.
DayRW, GuarinB, LynchJM, VernonDD, DeanJM. Inhaled nitric oxide in children with severe lung disease: results of acute and prolonged therapy with two concentrations. Crit Care Med1996;24(2):215–221.
62.
CheifetzIM, CraigDM, KernFH, BlackDR, HillmanND, GrealbyWJ, et al. Nitric oxide improves transpulmonary vascular mechanics but does not change intrinsic right ventricular contractility in an acute respiratory distress syndrome model with permissive hyper-capnia. Crit Care Med1996;24(9):1554–1559.
63.
OguraH, CioffiWG, OffnerPJ, JordonBS, JohnsonAA, PruittBAJr, et al. Effect of inhaled nitric oxide on pulmonary function after sepsis in a swine model. Surgery1994;116(2):313–321.
64.
OguraH, SaitohD, JohnsonAA, MasonADJr, PruittBAJr, CioffiWGJr. The effect of inhaled nitric oxide on pulmonary ventilation-perfusion matching following smoke inhalation injury. J Trauma1994;37(6):893–898.
65.
LavoieA, HallJB, OlsonDM, WylamME. Life-threatening effects of discontinuing inhaled nitric oxide in severe respiratory failure. Am J Respir Crit Care Med1996;153(6 Pt 1):1985–1987.
66.
LuQ, MourgeonE, Law-KouneJD, RocheS, VezinetC, Abden-hourL, et al. Dose-response curves of inhaled nitric oxide with and without intravenous almitrine in nitric oxide-responding patients with acute respiratory distress syndrome. Anesthesiology1995;83(5):929–943.
67.
WatkinsDN, JenkinsIR, RankinJM, ClarkeGM. Inhaled nitric oxide in severe acute respiratory failure—its use in intensive care and description of a delivery system. Anaesth Intensive Care1993;21(6):861–866.
68.
SamamaCM, DiabyM, FellahiJL, MdhaferA, EyraudD, ArockM, et al. Inhibition of platelet aggregation by inhaled nitric oxide in pa-tients with acute respiratory distress syndrome. Anesthesiology1995;83(1):56–65.
69.
YoshidaM, TaguchiO, GabazzaEC, KobayashiT, YamakamiT, KobayashiH, et al. Combined inhalation of nitric oxide and oxygen in chronic obstructive pulmonary disease. Am J Respir Crit Care Med1997;155(2):526–529.
70.
WesselDL, AdatiaI, ThompsonJE, HickeyPR. Delivery and monitoring of inhaled nitric oxide in patients with pulmonary hy-pertension. Crit Care Med1994;22(6):930–938.
71.
SydowM, BristowF, ZinserlingJ, AllenSJ. Variation of nitric oxide concentration during inspiration. Crit Care Med1997;25(2):365–371.
72.
SkimmingJW, BenderKA, HutchinsonAA, DrummondWH. Ni-tric oxide inhalation in infants with respiratory distress syndrome. J Pediatr1997;130(2):225–230.
73.
SkimmingJW, CassinS, BlanchPB. Nitric oxide administration using constant-flow ventilation. Chest1995;108(4):1065–1072.
74.
SkimmingJW, BlanchPB, BannerMJ. Behavior of nitric oxide infused at constant flow rates directly into a breathing circuit during controlled mechanical ventilation. Crit Care Med1997;25(8):1410–1416.
75.
WestfeltUN, LundinS, StenqvistO.Safety aspects of delivery and monitoring of nitric oxide during mechanical ventilation. Acta An-aesthesiol Scand1996;40(3):302–310.
76.
FourbertL, MareelsK, FredholmM, LundinS, StenqvistO.A study of mixing conditions during nitric oxide administration using simultaneous fast response chemiluminescence and capnography. Br J Anaesth1997;78(4):436–438.
77.
De JaegereAP, JacobsFI, LaheijNG, van den AnkerJN. Variation of inhaled nitric oxide concentration with the use of a continuous flow ventilator. Crit Care Med1997;25(6):995–1002.
78.
ImanakaH, HessD, KirmseM, BigatelloLM, KacmarekRM, SteudelW, et al. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation. Anesthesiology1997;86(3):676–688.
79.
TibballsJ, HochmannM, CarterB, OsborneA.An appraisal of techniques for administration of gaseous nitric oxide. Anaesth In-tens Care1993;21(6):844–847.
FredenF, WeiSZ, BerglundJE, FrostellC, HedenstiernaG.Nitric oxide modulation of pulmonary blood flow distribution in lobar hypoxia. Anesthesiology1995;82(5):1216–1225.
83.
ImanakaH, KacmarekRM, RitzR, HessD.Tracheal gas insuffla-tion—pressure control versus volume control ventilation. A lung model study. Am J Respir Crit Care Med1996;153(3):1019–1024.
KinsellaJP, SchmidtJM, GriebelJ, AbmanSH. Inhaled nitric oxide treatment for stabilization and emergency medical transport of criti-cally ill newborns and infants. Pediatrics1995;95(5):773–776.
86.
RossaintR, FalkeKJ, LopezF, SlamaK, PisonU, ZapolWM. Inhaled nitric oxide for the adult respiratory distress syndrome. New Engl J Med1993;328(6):399–405.
87.
RossaintR, GerlachH, Schmidt-RuhnkeH, PappertD, Lewan-dowskiK, SteudelW, FalkeK.Efficacy of inhaled nitric oxide in patients with severe ARDS. Chest1995;107(4):1107–1115.
88.
AbmanSH, GriebelJL, ParkerDK, SchmidtJM, SwantonD, Kin-sellaJP. Acute effects of inhaled nitric oxide in children with severe hypoxemic respiratory failure. J Pediatrics1994;124(6):881–888.
89.
MourgeonE, GallartL, RaoGS, LuQ, Law-KouneJD, PuybassetL, et al. Distribution of inhaled nitric oxide during sequential and continuous administration into the inspiratory limb of the ventila-tor. Intensive Care Med1997;23(8):849–858.
90.
WysockiM, DelclauxC, RoupieE, LangeronO, LiuN, HermanB, et al. Additive effect on gas exchange of inhaled nitric oxide and intravenous almitrine bismesylate in the adult respiratory distress syndrome. Intensive Care Med1994;20(4):254–259.
91.
YoungJD. A universal nitric oxide delivery system. Br J Anaesth1994;73(5):700–702.
92.
HovengaS, KoendersME, van der WerfTS, MoshageH, ZijlstraJG. Methaemoglobinemia after inhalation of nitric oxide for treat-ment of hydrochlorothiazide-induced pulmonary oedema. Lancet1996;348(9033):1035–1036.
93.
LevyB, BollaertPE, BauerP, NaceL, AudibertG, LarcanA.Therapeutic optimization including inhaled nitric oxide in adult respiratory distress syndrome in a polyvalent intensive care unit. J Trauma1995;38(3):370–374.
94.
PuybassetL, RoubyJJ, MourgeonE, StewartTE, CluzelP, ArthaudM, et al. Inhaled nitric oxide in acute respiratory failure: dose-response curves. Intensive Care Med1994;20(5):319–327.
PutensenC, RasanenJ, ThomsonMS, BramanRS. Method of delivering constant nitric oxide concentrations during full and par-tial ventilatory support. J Clin Monit1995;11(1):23–31.
98.
BenzingA, GeigerK.Inhaled nitric oxide lowers pulmonary cap-illary pressure and changes longitudinal distribution of pulmonary vascular resistance in patients with acute lung injury. Acta Anaes-thesiol Scand1994;38(7):640–645.
99.
PuybassetL, RoubyJJ, MourgeonE, CluzelP, SouhilZ, Law-KouneJD, et al. Factors influencing cardiopulmonary effects of inhaled nitric oxide in acute respiratory failure. Am J Respir Crit Care Med1995;152(1):318–328.
100.
SnellGI, SalamonsenRF, BerginP, EsmoreDS, KhanS, WilliamsTJ. Inhaled nitric oxide used as a bridge to heart-lung transplanta-tion in a patient with end-stage pulmonary hypertension. Am J Respir Crit Care Med1995;151(4):1263–1266.
101.
DayRW, LynchJM, ShaddyRE, OrsmundGS. Pulmonary vaso-dilatory effects of 12 and 60 parts per million inhaled nitric oxide in children with ventricular septal defect. Am J Cardiol1995;75(2):196–198.
102.
AdatiaI, LilleheiC, ArnoldJH, ThompsonJE, PalazzoR, FacklerJC, WesselDL. Inhaled nitric oxide in the treatment of postoper-ative graft dysfunction after lung transplantation. Ann Thorac Surg1994;57(5):1311–1318.
103.
BigatelloLM, HurfordWE, KacmarekRM, RobertsJDJr, ZapolWM. Prolonged inhalation of low concentrations of nitric oxide in patients with severe adult respiratory distress syndrome. Effects on pulmonary hemodynamics and oxygenation. Anesthesiology1994;80(4):761–770.
104.
BlomqvistH, WickertsCJ, AndreenM, UllbergU, OrtquistA, FrostellC, et al. Enhanced pneumonia resolution by inha-lation of nitric oxide?Acta Anaesthesiol Scand1993;37(1):110–114.
105.
PutensenC, RasanenJ, DownsJB. Effect of endogenous and inhaled nitric oxide on the ventilation-perfusion relationships in oleic-acid lung injury. Am J Respir Crit Care Med1994;150(2):330–336.
106.
PutensenC, RasanenJ, LopezFA. DownsJB. Continuous positive airway pressure modulates effect of inhaled nitric oxide on the ventilation-perfusion distributions in canine lung injury. Chest1994;106(5):1563–1569.
107.
ChannickRN, NewhartJW, JohnsonFW, MoserKM. Inhaled ni-tric oxide reverses hypoxic pulmonary vasoconstriction in dogs. A practical nitric oxide delivery and monitoring system. Chest1994;105(6):1842–1847.
108.
McIntyreRCJr, MooreFA, MooreEE, PiedalueF, HaenelJS, FullertonDA. Inhaled nitric oxide variably improves oxygenation and pulmonary hypertension in patients with acute respiratory distress syndrome. J Trauma1995;39(3):418–425.
109.
JohannigmanJA, CampbellRS, DavisKJr, HurstJM. Combined differential lung ventilation and inhaled nitric oxide therapy in the management of unilateral pulmonary contusion. J Trauma1997;42(1):108–111.
DellingerRP, ZimmermanJL, TaylorRW, StraubeRC, HauserDL, CrinerGJ, et al. Effects of inhaled nitric oxide in patients with acute respiratory distress syndrome: results of a randomized phase II trial. Inhaled Nitric Oxide in ARDS Study Group. Crit Care Med1998;26(1):15–23.
112.
GraybealJ, SchulerGH, LarachDR. Instability of nitric oxide concentration delivered from a two-blender system (letter). Crit Care Med1995;23(9):1611–1612.
113.
BeghettiM, HabreW, FriedliB, BernerM.Continuous low dose inhaled nitric oxide for treatment of severe pulmonary hypertension after cardiac surgery in paediatric patients. Br Heart J1995;73(1):65–68.
114.
BetitP.Nitric oxide administration during pediatric mechanical ventilation. Respir Care Clin N Am1996;2(4):587–605.
115.
BetitP, AdatiaI, BenjaminP, ThompsonJE, WesselDL. Inhaled nitric oxide: evaluation of a continuous titration delivery technique for infant mechanical and manual ventilation. Respir Care1995;40(7):706–715.
116.
FierobeL, BrunetF, DhainautJF, MonchiM, BelghirthM, MiraJP, et al. Effect of inhaled nitric oxide on right ventricular function in adult respiratory distress syndrome. Am J Respir Crit Care Med1995;151(5):1414–1419.
117.
KinsellaJP, IvyDD, AbmanSH. Inhaled nitric oxide improves gas exchange and lowers pulmonary vascular resistance in severe ex-perimental hyaline membrane disease. Pediatr Res1994;36(3):402–408.
118.
LonnqvistPA, JonssonB, WinbergP, FrostellCG. Inhaled nitric oxide in infants with developing or established chronic lung dis-ease. Acta Paediatr1995;84(10):1188–1192.
119.
LonnqvistPA, WinbergP, LundellB, SelldenH, OlssonGL. Inhaled nitric oxide in neonates and children with pulmonary hyper-tension. Acta Paediatr1994;83(11):1132–1136.
120.
LeclercF, RiouY, MartinotA, StormeL, HueV, FlurinV, et al. Inhaled nitric oxide for a severe respiratory syncytial virus infection in an infant with bronchopulmonary dysplasiatitle>. Intensive Care Med1994;20(7):511–512.
121.
MillerOL, CelermajerDS, DeanfieldJE, MacraeDJ. Guidelines for the safe administration of inhaled nitric oxide. Arch Dis Child Fetal Neonatal Ed1994;70(1):F47–F49.
122.
MillerOL, CelermajerDS, DeanfieldJE, MacraeDJ. Very-low-dose inhaled nitric oxide: a selective pulmonary vasodilator after operations for congenital heart disease. J Thor Cardiovasc Surg1994;108(3):487–494.
123.
Inhaled nitric oxide in full-term and nearly full-term infants with hypoxic respiratory failure. The Neonatal Inhaled Nitric Oxide Study Group. N Engl J Med1997;336(9):597–604. Published erratum appears in N Engl J Med 1997;337(6):434.
124.
RobertsJDJr, FinemanJR, MorinFC3rd, ShaulPW, RimarS, SchreiberMD, et al. Inhaled nitric oxide and persistent pulmonary hypertension of the newborn. The Inhaled Nitric Oxide Study Group. N Engl J Med1997;336(9):605–610.
125.
MortimerTW, MathMCM, FajardoCA. Inhaled nitric oxide de-livery with high-frequency jet ventilation: a bench study. Respir Care1996;41:895–899.
126.
RitzR, HessD, HeadCA, KacmarekR.Nitric oxide and nitrogen dioxide levels during manual ventilation (abstract). Respir Care1995;40:1184.
127.
GroverR, MurdochI, SmithiesM, MitchellI, BihariD.Nitric oxide during hand ventilation in a patient with acute respiratory failure. Lancet1992;340(8826):1038–1039.
128.
KirmseM, HessD, FujinoY, KacmarekRM, HurfordWE. Deliv-ery of inhaled nitric oxide using the Ohmeda INOvent Delivery System. Chest1998;113(6):1650–1657.
129.
YoungJD, RobertsM, GaleLB. Laboratory evaluation of the I-NOvent nitric oxide delivery device. Brit J Anaesth1997;79(3):398–401.
130.
SydowM, BristowF, ZinserlingJ, AllenSJ. Flow-proportional administration of nitric oxide with a new delivery system. Chest1997;112(2):496–504.
131.
GerlachH, PappertD, LewandowskiK, RossaintR, FalkeKJ. Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respi-ratory distress syndrome. Intensive Care Med. 1993;19(8):443–449.
132.
GerlachH, RossaintR, PappertD, FalkeKJ. Time-course and dose-response of nitric oxide inhalation for systemic oxygenation and pulmonary hypertension in patients with adult respiratory dis-tress syndrome. Eur J Clin Invest. 1993;23(8):499–502.
133.
O'HareB, BetitP, ThompsonJ, et al. In-vivo evaluation of a composite pediatric nitric oxide delivery monitoring system (ab-stract). Crit Care Med. 1997;25:A54.
LindbergL, RydgrenG, LarssonA, OlssonSG, NordstromL.A delivery system of inhalation of nitric oxide evaluated with chemi-luminescence, electrochemical fuel cells, and capnography. Crit Care Med. 1997;25(1):190–196.
136.
ChannickRN, NewhartJW, JohnsonFW, WilliamsPJ, AugerWR, FedulloPF. Pulsed delivery of inhaled nitric oxide to patients with primary pulmonary hypertension. An ambulatory delivery system and initial clinical tests. Chest. 1996;109(6):1545–1549.
137.
MatthewsR, SawyerR, ScheferR.Interferences in chemilumines-cent measurement of NO and NO2 emissions from combustion systems. Environ Sci Tech. 1977;11:1092–1099.
138.
BatheD, BerssenbruggeA, KohlmanT, et al. Monitoring accuracy for the measurement of nitric oxide in the 0 to 80 ppm range (abstract). Crit Care Med. 1996;24:A103.
139.
EtchesPC, HarrisML, McKinleyR, FinerNN. Clinical monitoring of inhaled nitric oxide: comparison of chemiluminescent and elec-trochemical sensors. Biomed Instrum Tech. 1995;29(2):134–140.
140.
MiyamotoK, AidaA, NishimuraM, NakanoT, KawakamiY, OhmoriY, et al. Effects of humidity and temperature on nitrogen dioxide formation from nitric oxide. Lancet. 1994;343(8905):1099–1110.
141.
MoutafisM, HatahetZ, CastelainMH, RenaudinMH, MonnotA, FischlerM.Validation of a simple method assessing nitric oxide and nitrogen dioxide concentrations. Intensive Care Med. 1995;21(6):537–541.
NelinLD, ChristmanNT, MorriseyJF, DawsonCD. Electrochem-ical nitric oxide and nitrogen dioxide analyzer for use with inhaled nitric oxide. J Appl Physiol. 1996;81(3):1423–1429.
144.
PetrosAJ, CoxPB, BohnD.Simple method for monitoring con-centration of inhaled nitric oxide (letter). Lancet. 1992;340(8828):1167.
145.
PurtzEP, HessD, KacmarekRM. Evaluation of electrochemical nitric oxide and nitrogen dioxide analyzers suitable for use during mechanical ventilation. J Clin Monit. 1997;13(1):25–34.
146.
StraussJM, KrohnS, SumpelmannR, SchroderD, BarnertR.Eval-uation of two electrochemical monitors for measurement of inhaled nitric oxide. Anaesthesia. 1996;51(2):151–154.