PepePE, MariniJJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis1982;126(1):166–170.
2.
RossiA, GottfriedSB, ZocchiL, HiggsBD, LennoxS, CalverleyPM, et al. Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation. The effect of intrinsic positive end-expiratory pressure. Am Rev Respir Dis1985;131(5):672–677.
3.
BrownD, PiersonDJ. Auto-PEEP is common in mechanically ventilated patients: a study of incidence, severity, and detection. Respir Care1986;31(11):1069–1074.
4.
ScottLR, BensonMS, BishopMJ. Relationship of endotracheal tube size to auto-PEEP at high minute ventilation. Respir Care1986;31(11):1080–1085.
5.
MariniJJ. Should PEEP be used in airflow obstruction? (editorial)Am Rev Respir Dis1989;140(1):1–3.
6.
KacmarekR.Positive end-expiratory pressure. In: PiersonDJ, KacmarekR, editors. Foundations of respiratory care. New York: Churchill Livingstone, 1992.
7.
KacmarekR, HessD.Airway pressure, flow and volume waveforms, and lung mechanics during mechanical ventilation. In: Monitoring in respiratory care. St Louis: Mosby-Year Book, 1993.
8.
BensonMS, PiersonDJ. Auto-PEEP during mechanical ventilation. Respir Care1988;33(7):557–568.
9.
MadsenD, JagerK, FenwickJ, TweeddaleM.Expiratory hold vs clamping/transducer for intrinsic PEEP determination in the Siemens 900C. Respir Care1994;39(6):623–626.
10.
SmithTC, MariniJJ. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Appl Physiol1988;65(4):1488–1499.
11.
CaviedesI, BenitoS, ManceboJ, NetA.Effect of intrinsic positive end-expiratory pressure on respiratory compliance. Crit Care Med1986;14(11):947–949.
12.
MariniJJ. Lung mechanics determinations at the bedside: instrumentation and clinical application. Respir Care1990;35(7):669–696.
13.
BaydurA, BehrakisK, ZinA, et al. A simple method for assessing the validity of esophageal balloon technique. Am Rev Respir Dis1982;126(5):788–791.
14.
LindFG, TruveAB, LindborgBP. Microcomputer-assisted on-line measurement of breathing pattern and occlusion pressure. J Appl Physiol1984;56(1):235–239.
15.
MaltaisF, SoviljM, GoldbergP, GottfriedSB. Respiratory mechanics in status asthmaticus: effects of inhalational anesthesia. Chest1994;106(5):1401–1406.
16.
BoysenPG, BannerMJ, JaegerMJ. Inspiratory times and flow-wave patterns in relation to distribution of ventilation (abstract). Anesthesiology1985;63:A560.
17.
ConnorsAFJr, McCaffreeDR, GrayBA. Effects of inspiratory flow rate on gas exchange during mechanical ventilation. Am Rev Respir Dis1981;124(5):537–543.
18.
FeltonCR, MontenegroHD, SaidelGM. Inspiratory flow effects on mechanically ventilated patients: lung volumes, inhomogeneity and arterial oxygenation. Intensive Care Med1984;10(6):281–286.
19.
TobinMJ, LodatoRF. PEEP, auto-PEEP, and waterfalls (editorial). Chest1989;96(3):449–451.