SassoonCSH, MahutteCK. What you need to know about the ventilator in weaning. Respir Care1995;40(3):249–256.
2.
BransonRD. Flow-triggering systems (Kittredge's Corner). Respir Care1994;39(2):138–144.
3.
BransonRD, CampbellRS, DavisKJr, JohnsonDJ. Comparison of pressure and flow triggering systems during continuous positive airway pressure. Chest1994;106(2):540–544.
4.
PoleseG, MassaraA, PoggiR, BrandoleseR, BrandiG, RossiA.Flow-triggering reduces inspiratory effort during weaning from mechanical ventilation. Intensive Care Med1995;21(8):682–686.
5.
BransonRD, DavisKJr. Work of breathing imposed by five ventilators used for long-term support: the effects of PEEP and simulated patient demand. Respir Care1995;40(12):1270–1278.
6.
HirschC, KacmarekRM, StanekK.Work of breathing during CPAP and PSV imposed by the new generation mechanical ventilators: a lung model study. Respir Care1991;36(8):815–820.
7.
BannerMJ, KirbyRR, BlanchPB. Site of pressure measurement during spontaneous breathing with continuous positive airway pressure: effect on calculating imposed work of breathing. Crit Care Med1992;20(4):528–533.
8.
BannerMJ, BlanchPB, KirbyRR. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system. Crit Care Med1993;21(2):183–190.
9.
BannerMJ, JaegerMJ, KirbyRR. Components of the work of breathing and implications for monitoring ventilator-dependent patients. Crit Care Med1994;22(3):515–523.
10.
MessingerG, BannerMJ, BlanchPB, LayonAJ. Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing. Chest1995;108(2):509–514.
11.
ShapiroM, WilsonRK, CasarG, BloomK, TeagueRB. Work of breathing through different sized endotracheal tubes. Crit Care Med1986;14(12):1028–1031.
12.
BhattSB, PatelCB, TanIKS, VernascoD, TamYH. Imposed work of breathing during tracheal pressure triggering using a demand valve CPAP system. Respir Care1996;41(6):512–518.
13.
MacIntyreNR. What Is Tracheal Pressure Triggering and Do We Need It? Yes! (points-of-view). Respir Care1996;41(6):524–525.
14.
FiastroJF, HabibMP, QuanSF. Pressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure. Chest1988;93(3):499–505.
15.
BerstenAD, RuttenAJ, VedigAE. Efficacy of pressure support in compensating for apparatus work. Anaesth Intens Care1993;21(1):67–71.
16.
KirtonOC, DeHavenCB, MorganJP, WindsorJ, CivettaJM. Elevated imposed work of breathing masquerading as ventilator weaning intolerance. Chest1995;108(4):1021–1025.
17.
GuttmannJ, EberhardL, FabryB, BertschmannW, WolffG.Continuous calculation of intratracheal pressure in tracheally intubated patients. Anesthesiology1993;79(3):503–513.