KollefMH. The prevention of ventilator-associated pneumonia. N Engl J Med1999;340(8):627–634.
2.
KollefMH, SilverP.Ventilator-associated pneumonia: an update for clinicians. Respir Care1995;40(11):1130–1140.
3.
CookDJ, KollefMH. Risk factors for ICU-acquired pneumonia. JAMA1998;279(20):1605–1606.
4.
CookD, De JongheB, BrochardL, Brun-BuissonC.Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA1998;279(10):781–787.
5.
DemersRR. Bacterial/viral filtration: let the breather beware!Chest2001;120(4):1377–1389.
6.
CravenDE, ConnollyMGJr, LichtenbergDA, PrimeauPJ, McCabeWR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med1982;306(25):1505–1509.
7.
DreyfussD, DjedainiK, WeberP, BrunP, LanoreJJ, RahmaniJ, et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis1991;143(4 Pt 1):738–743.
8.
CravenDE, KunchesLM, KilinskyV, LichtenbergDA, MakeBJ, McCabeWR. Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Respir Dis1986;133(5):792–796.
9.
KollefMH, ShapiroSD, FraserVJ, SilverP, MurphyDM, TrovillionE, et al. Mechanical ventilation with or without 7-day circuit changes: a randomized controlled trial. Ann Intern Med1995;123(3):168–174.
10.
LongMN, WickstromG, GrimesA, BentonCF, BelcherB, StammAM. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week. Infect Control Hosp Epidemiol1996;17(1):14–19.
11.
LareauSC, RyanKJ, DienerCF. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis1978;118(3):493–496.
12.
HessD, BurnsE, RomagnoliD, KacmarekRM. Weekly ventilator circuit changes: a strategy to reduce costs without affecting pneumonia rates. Anesthesiology1995;82(4):903–911.
13.
ThompsonRE. Incidence of ventilator-associated pneumonia (VAP) with 14-day circuit change in a subacute environment. Respir Care1996;41(7):601–606.
14.
KotilainenHR, KeroackMA. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit. Am J Infect Control1997;25(4):117–120.
15.
FinkJB, KrauseSA, BarrettL, SchaaffD, AlexCG. Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia. Chest1998;113(2):405–411.
16.
HanJN, LiuYP, MaS, ZhuYJ, SuiSH, ChenXJ, et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing hospital. Respir Care2001;46(9):891–896.
17.
TrybaM.Sucralfate versus antacids or H2-antagonists for stress ulcer prophylaxis: a meta-analysis on efficacy and pneumonia rate. Crit Care Med1991;19(7):942–949.
18.
CookDJ, LaineLA, GuyattGH, RaffinTA. Nosocomial pneumonia and the role of gastric pH: a meta-analysis. Chest1991;100(1):7–13.
19.
CookDJ, ReeveBK, ScholesLC. Histamine-2-receptor antagonists and antacids in the critically ill population: stress ulceration versus nosocomial pneumonia. Infect Control Hosp Epidemiol1994;15(7):437–442.
20.
TorresA, Serra-BatllesJ, RosE, PieraC, Puig de la BellacasaJ, CobosA, et al. Pulmonary aspiration of gastric contents in patients requiring mechanical ventilation: the effect of body position. Ann Intern Med1992;116(7):540–543.
21.
Orozco-LeviM, TorresA, FerrerM, PieraC, el-EbiaryM, de la BellacasaJP, Rodriguez-RoisinR.Semirecumbent position protects from pulmonary aspiration but not completely from gastroesophageal reflux in mechanically ventilated patients. Am J Respir Crit Care Med1995;152(4 Pt 1):1387–1390.
22.
MahulP, AuboyerC, JospeR, RosA, GuerinC, el KhouriZ, et al. Prevention of nosocomial pneumonia in intubated patients: respective role of mechanical subglottic secretions drainage and stress ulcer prophylaxis. Intensive Care Med1992;18(1):20–25.
23.
VallesJ, ArtigasA, RelloJ, BonsomsN, FontanalsD, BlanchL, et al. Continuous aspiration of subglottic secretions in preventing ventilator-associated pneumonia. Ann Intern Med1995;122(3):179–186.
24.
RelloJ, SonoraR, JubertP, ArtigasA, RueM, VallesJ.Pneumonia in intubated patients: role of respiratory airway care. Am J Respir Crit Care Med1996;154(1):111–115.
25.
KollefMH, SkubasNJ, SundtTM. A randomized clinical trial of continuous aspiration of subglottic secretions in cardiac surgery patients. Chest1999;116(5):1339–1346.
26.
MartinC, PerrinG, GevaudanMJ, SauxP, GouinF.Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest1990;97(1):144–149.
27.
RoustanJP, KienlenJ, AubasP, AubasS, du CailarJ.Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med1992;18(2):97–100.
28.
DreyfussD, DjedainiK, GrosI, MierL, Le BourdellesG, CohenY, et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med1995;151(4):986–992.
29.
BransonRD, DavisKJr, BrownR, RashkinM.Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care1996;41(9):809–816.
30.
HurniJM, FeihlF, LazorR, LeuenbergerP, PerretC.Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest1997;111(3):686–691.
31.
KirtonOC, DeHavenB, MorganJ, MorejonO, CivettaJ.A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest1997;112(4):1055–1059.
32.
KollefMH, ShapiroSD, BoydV, SilverP, Von HarzB, TrovillionE, PrenticeD.A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest1998;113(3):759–767.
33.
PelosiP, SolcaM, RavagnanI, TubioloD, FerrarioL, GattinoniL.Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure support ventilation in acute respiratory failure. Crit Care Med1996;24(7):1184–1188.
34.
Le BourdellesG, MierL, FiquetB, DjedainiK, SaumonG, CosteF, DreyfussD.Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest1996;110(5):1294–1298.
35.
CohenIL, WeinbergPF, FeinIA, RowinskiGS. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med1988;16(3):277–279.
36.
MissetB, EscudierB, RivaraD, LeclercqB, NitenbergG.Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: a prospective randomized study. Chest1991;100(1):160–163.
37.
VillafaneMC, CinnellaG, LofasoF, IsabeyD, HarfA, LemaireF, BrochardL.Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology1996;85(6):1341–1349.