KollefMH. The prevention of ventilator-associated pneumonia. N Engl J Med1999;340(8):627–634.
2.
BransonRD, MacIntyreN, editors. Humidification: current therapy and controversy. Respir Care Clin N Am1998;4(2):199–339.
3.
CookD, De JongheB, BrochardL, Brun-BuissonC.Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA1998;279(10):781–787.
4.
LareauSC, RyanKJ, DienerCF. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis1978;118(3):493–496.
5.
CravenDE, ConnollyMGJr, LichtenbergDA, PrimeauPJ, McCabeWR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med1982;306(25):1505–1509.
6.
CravenDE, KunchesLM, KilinskyV, LichtenbergDA, MakeBJ, McCabeWR. Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Respir Dis1986;133(5):792–796.
7.
DreyfussD, DjedainiK, WeberP, BrunP, LanoreJJ, RahmaniJ, et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis1991;143(4 Pt 1):738–743.
8.
HessD, BurnsE, RomagnoliD, KacmarekRM. Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates. Anesthesiology1995;82(4):903–911.
9.
KollefMH, ShapiroSD, FraserVJ, SilverP, MurphyDM, TrovillionE, et al. Mechanical ventilation with or without 7-day circuit changes: a randomized controlled trial. Ann Intern Med1995;123(3):168–174.
10.
CookD, RicardJD, ReeveB, RandallJ, WiggM, BrochardL, DreyfussD.Ventilator circuit and secretion management strategies: a Franco-Canadian survey. Crit Care Med2000;28(10):3547–3554.
11.
HanJN, LiuYP, MaS, ZhuYJ, SuiSH, ChenXJ, et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing hospital. Respir Care2001;46(9):891–896.
12.
LongMN, WickstromG, GrimesA, BentonCF, BelcherB, StammAM. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus 3 ventilator circuit changes per week. Infect Control Hosp Epidemiol1996;17(1):14–19.
13.
KotilainenHR, KeroackMA. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit. Am J Infect Control1997;25(2):117–120.
14.
FinkJB, KrauseSA, BarrettL, SchaaffD, AlexCG. Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia. Chest1998;113(2):405–411.
15.
DjedainiK, BilliardM, MierL, Le BourdellesG, BrunP, MarkowiczP, et al. Changing heat and moisture exchangers every 48 hours rather than every 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med1995;152(5 Pt 1):1562–1569.
16.
ThomachotL, VialetR, ViguierJM, SidierB, RoulierP, MartinC.Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Crit Care Med1998;26(3):477–481.
17.
KollefMH, ShapiroSD, BoydV, SilverP, Von HartzB, TrovillionE, PrenticeD.A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest1998;113(3):759–767.
18.
MarkowiczP, RicardJ-D, DreyfussD, MierL, BrunP, CosteF, et al. Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med2000;28(3):665–671.
19.
RicardJ-D, Le MièreE, MarkowiczP, LasryS, SaumonG, DjedainiK, et al. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med2000;161(1):104–109.
20.
DavisKJr, EvansSL, CampbellRS, JohannigmanJA, LuchetteFA, PorembkaDT, BransonRD. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med2000;28(5):1412–1418.