ACCP-ATS Joint Committee on Pulmonary Nomenclature.Pulmonary terms and symbols.Chest1975;67(5):583–593.
2.
QuanjerPH, TammelingGJ, CotesJE, PedersenOF, PeslinR, YernaultJC.Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society.Eur Respir J Suppl1993Mar;16:5–40.
3.
American Thoracic Society.Lung function testing: selection of reference values and interpretative strategies.Am Rev Respir Dis1991;144:1202–1218.
4.
AaronSD, DalesRE, CardinalP.How accurate is spirometry at predicting restrictive pulmonary impairment?Chest1999;115:869–873.
5.
WadeJF, MortensonR, IrvinCG.Physiologic evaluation of bullous emphysema.Chest1991;100(4):1151–1154.
6.
American Thoracic Society.Standardization of spirometry: 1994 update.Am J Respir Crit Care Med1995;152(3):1107–1136.
7.
American Association for Respiratory Care.AARC Clinical practice guideline: Spirometry, 1996 update.Respir Care1996;41(7):629–636.
8.
MillerWF, ScacciR, GastLR.Laboratory evaluation of pulmonary function.Philadelphia: JB Lippincott; 1987:137.
9.
BedellGN, MarshallR, DuBoisAB, ComroeJH.Plethysmographic determination of the volume of gas trapped in the lungs.J Clin Invest1956;35:664–670.
10.
RossJC, CopherDE, TeaysJD, LordTJ.Functional residual capacity in patients with pulmonary emphysema.Ann Intern Med1962;57:18–28.
11.
RodensteinDO, StanescuDC, FrancisC.Demonstration of failure of body plethysmography in airway obstruction.J Appl Physiol1982;52(4):949–954.
12.
ShoreSA, HukO, MannixS, MartinJG.Effect of panting frequency on the plethysmographic determination of thoracic gas volume in chronic obstructive pulmonary disease.Am Rev Respir Dis1983;128(1):54–59.
13.
ShoreS, Milic-EmiliJ, MartinJG.Reassessment of body plethysmographic technique for the measurement of thoracic gas volume in asthmatics.Am Rev Respir Dis1982;126(3):515–520.
14.
GardnerRM, CrapoRO, NelsonSB.Spirometry and flow-volume curves.Clin Chest Med1989;10(2):145–154.
15.
DarlingRC, CournandA, RichardsDW Jr.Studies on intrapulmonary mixture of gases. III. Open circuit methods for measuring residual air.J Clin Lab Invest1940;19:609–618.
16.
ClausenJL, editor.Pulmonary function testing: guidelines and controversies.New York: Academic Press; 1982.
17.
British Thoracic Society and Association of Respiratory Technicians and Physiologists.Guidelines for the measurement of respiratory function.Respir Med1994;88:165–194.
18.
MeneelyGR, BallCO, KoryRC, .A simplified closed circuit helium dilution method for the determination of the residual volume of the lungs.Am J Med1960;28:824–831.
19.
RodensteinDO, StanescuDC.Frequency dependence of plethysmographic volume in healthy and asthmatic subjects.J Appl Physiol1983;54(1):159–165.
20.
American Thoracic Society. WangerJ, editor.Pulmonary function laboratory management and procedure manual.1998:13–14.
21.
SchanningCG, GulsvikA.Accuracy and precision of helium dilution technique and body plethysmography in measuring lung volumes.Scand J Clin Lab Invest1983;32:271–277.
22.
DuBoisAB, BotelhoSY, BedellGN, MarshalR, ComroeJH.A rapid plethysmographic method for measuring thoracic gas volume: a comparison with a nitrogen wash-out method for measuring functional residual capacity.J Clin Lab Invest1956;35:322–326.
23.
BohadanaAB, TeculescuD, PeslinR, Jansen da SilvaJM, PinoJ.Comparison of four methods for calculating the total lung capacity measured by body plethysmograph.Bull Eur Physiopathol Respir1980;16(6):769–776.
24.
BurkiNK.The effects of changes in functional residual capacity with posture on mouth occlusion pressure and ventilatory pattern.Am Rev Respir Dis1977;116(5):895–900.
25.
ParotS, ChaudunE, JacqueminE.The origin of postural variations of human lung volumes as explained by the effects of age.Respiration1970;27(3):254–260.
26.
GoldmanHL, BecklakeMR.Respiratory function tests: normal values at median altitude and the prediction of normal results.Am Rev Thorac Pulmon Dis1969;79:457–467.
27.
CotesJE, SaundersMJ, AdamJER, AndersonHR, HallAM.Lung function in coastal and highland New Guineans-comparisons with Europeans.Thorax1973;28(3):320–330.
ClausenJL.Prediction of normal values in pulmonary function testing.Clin Chest Med1989;10(2):135–143.
30.
QuanjerPH.Predicted values: how should we use them? (letter)Thorax1988;43(8):663–664.
31.
NCCLS.GP26-A A quality system model for health care: approved guideline (1999).Available from NCCLS: phone 610-688-0100; Fax 610-688-0700; e-mail exoffice@nccls.org.
32.
NCCLS.HS4-A A quality system model for respiratory care.Available from NCCLS: phone 610-688-0100; Fax 610-688-0700; e-mail exoffice@nccls.org.
33.
QuanjerPH, AndersenLH, TammelingGJ.Static lung volumes and capacities. Report of Working Party for Standardization of Lung Function Tests, European Community for Steel and Coal.Bull Eur Physiopathol Respir1983;19(5, Suppl):11–21.
34.
RuppelGL.Manual of pulmonary function testing, 7th ed.St Louis: CV Mosby; 1998:304–306.
35.
GardnerRM, ClausenJL, CrapoRO, EplerGR, HankinsonJL, JohnsonJL Jr, PlummerAL, American Thoracic Society Committee on Proficiency Standards for Clinical Pulmonary Laboratories.Quality assurance in pulmonary function laboratories.Am Rev Respir Dis1986;134(3):625–627.
36.
GarnerJS, Hospital Infection Control Practices Advisory, Centers for Disease Control and Prevention.Guideline for isolation precautions in hospitals.Am J Infect Control1996;24(1):24–31 or http//www.apic.org/html/resc/gdisolat.html.
37.
Centers for Disease Control & Prevention, Hospital Infection Control Practices Advisory Committee.Guideline for infection control in health care personnel, 1998.Am J Infect Control1998;26:269–354 or Infect Control Hosp Epidemiol 1998;19(6):407–463.
38.
LarsonEL.APIC guideline for handwashing and hand antisepsis in health care settings.Am J Infect Control1995;23(4):259–269.
KirkYL, KendayK, AshworthHA, HunterPR.Laboratory evaluation of a filter for the control of cross-infection during pulmonary function testing.J Hosp Infect1992;20:193–198.
41.
RutalaWA.APIC guideline for selection and use of disinfectants.Am J Infect Control1990;18(2):99–117.