MohlerJG, CollierCR, BrandtW, AbramsonJ, KerkaikG, YatesS.Blood gases. In: ClausenJL, editor. Pulmonary function testing guidelines and controversies: equipment, methods, and normal values. New York: Academic Press; 1982: 251.
2.
American Thoracic Society. Standards for the diagnosis and care of patients with chronic obstructive pulmonary disease: official statement. Am J Respir Crit Care Med1995;152(3):S77–S120.
3.
CaroneM, PatessioA, AppendiniL, PurroA, CzernickaE, ZanaboniS, DonnerCF. Comparison of invasive and non-invasive saturation monitoring in prescribing oxygen during exercise in COPD patients. Eur Respir J1997;10(2):446–451.
ZeballosRJ, WeismanIM. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am Rev Respir Dis1991;144:1240–1244.
6.
SchnappLM, CohenNH. Pulse oximetry uses and abuses. Chest1990;98(5):1244–1250.
7.
EscourrouPJL, DelapercheMF, VisseauxA.Reliability of pulse oximetry during exercise in pulmonary patients. Chest1990;97(3):635–638.
8.
PowersSK, DoddS, FreemanJ, AyersGD, SamsonH, McKnightT.Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise1989; 67(1):300–304.
9.
DouglasNJ, BrashHM, WraithPK, CalverleyPM, LeggettRJ, McElderryL, FlenleyDC. Accuracy sensitivity to carboxyhemoglobin, and speed of response of the Hewlett-Packard 47201A ear oximeter. Am Rev Respir Dis1979;119(2):311–313.
10.
HansenJE, CasaburiR.Validity of ear oximetry in clinical exercise testing. Chest1987;91(3):333–337.
11.
PowersSK, DoddS, WoodyardJ, BeadleRE. Haemoglobin saturation during incremental arm and leg exercise. Br J Sports Med1984;18(3):212–216.
12.
SmythRJ, D'UrzoAD, SlutskyAS, GalkoBM, RebuckAS. Ear oximetry during combined hypoxia and exercise Periodicals 1986;60(2):716–719.
13.
RiesAL, FedulloPF, ClausenJL. Rapid changes in arterial blood gas levels after exercise in pulmonary patients.Chest1983;83(3):454–456.
14.
FryeM, DiBenedettoR, LainD, MorganK.Single arterial puncture vs arterial cannula for arterial gas analysis after exercise.Chest1988;93(2):294–298.
15.
RiesAL, FarrowJT, ClausenJL. Accuracy of two ear oximeters at rest and during exercise on pulmonary patients.Am Rev Respir Dis1985;32:685–689.
16.
ClarkJS, VotteriB, AriagnoRL, CheungP, EichhornJH, FallatRJ, et al. Noninvasive assessment of blood gases.Am Rev Respir Dis1992;145(1):220–232.
17.
FukushimaT, OhruiT, ItabashiS, SekizawaK, AikawaT, YanaiM, et al. Prolonged hypoxemia after 10 minutes walking exercise in aged patients with chronic obstructive pulmonary disease.Tohoku J Exp Med1990;162(4):345–353.
18.
RiesAL, FarrowJT, ClausenLF. Pulmonary function tests cannot predict exercise-induced hypoxemia in COPD.Chest1988;93:454–459.
19.
MooreDP, WestonAR, HughesJMB, OakleyCM, ClelandJGF. Effects of increased inspired oxygen concentrations on exercise performance in chronic heart failure.Lancet1992;339:850–853.
20.
CarloneS, AngelieiE, PalangeP, SerraP, FarberMO. Effects of fenoterol on oxygen transport in patients with chronic airflow obstruction.Chest1988;93(4):790–794.
21.
BowerJS, BrookCJ, ZimmerK, DavisD.Performance of a demand oxygen saver system during rest, exercise, and sleep in hypoxemic patients.Chest1988;94(1):77–80.
MoriceRC, PetersEJ, RyanMB, PutnamJB, AliMK, RothJA. Exercise testing in the evaluation of patients at high risk for complications from lung resection.Chest1992;101:356–361.
24.
BrittonMG, AppsMCP, MaxwellDL, HughesDTD, HansonA.The value of ear lobe oximetry in the assessment of disability in asbestos-related disease.Respir Med1989;83:43–49.
25.
American College of Sports Medicine. Guidelines for graded exercise testing and exercise prescription, 5th ed. Pennsylvania: Williams & Wilkins; 1995.
26.
GibbonsRJ, BaladyGJ, BeasleyJW, BrickerJT, DuvernoyWF, FroelicherVF, et al. ACC/AHA Guidelines for Exercise Testing: A report of the American College of Cardiology and the American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing).J Am Coll Cardiol1997;30(1):260–311.
27.
GibbonsRJ, BaladyGJ, BeasleyJW, BrickerJT, DuvernoyWF, FroelicherVF, et al. ACC/AHA guidelines for exercise testing: executive summary. a report of the American College of Cardiology and the American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing).ACC/AHA Practice Guidelines. Circulation1997;96(1):345–354.
28.
PinaIL, BaladyGJ, HansonP, LabovitzAJ, MadonnaDW, MyersJ.Guidelines for clinical exercise testing laboratories. A statement for healthcare professionals from the Committee on Exercise and Cardiac Rehabilitation, American Heart Association.Circulation1995;91(3):912–921.
29.
WassermanK, HansenJE, SueDY, CasaburiR, WhippBJ. Principles of exercise testing and interpretation, 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 1999.
30.
American Association for Respiratory Care. AARC Clinical Practice Guideline: Pulse oximetry.Respir Care1991;36(12):1046–1048.
31.
American Association for Respiratory Care. AARC Clinical Practice Guideline: Sampling for arterial blood gas analysis.Respir Care1992;37(8):913–917.
32.
American Association for Respiratory Care. AARC Clinical Practice Guideline: Arterial blood analysis 2001 revision & update.Respir Care2001;46(5):498–505.
33.
WoodRJ, GoreCJ, HahnAG, NortonKI, ScroopGC, CampbellDP, et al. Accuracy of two pulse oximeters during maximal cycling exercise.Austral J Sci Med in Sport1997;29(2):47–50.
34.
NortonLH, SquiresB, CraigP, McLeayG, McGrathP, NortonKI. Accuracy of pulse oximetry during exercise stress testing.Int J Sports Med1992;13(7):523–527.
35.
SeveringhausJW, NaifehKH. Accuracy of response of six pulse oximeters to profound hypoxia.Anesthesiology1987;67:551–558.
36.
SeveringhausJW, NaifehKH, KohSO. Errors in 14 pulse oximeters during profound hypoxia.J Clin Monit1989;5:72–81.
37.
DubachP, FroelicherVF, KleinJ, OakesD, Grover-McKayM, FriisR.Exercise-induced hypotension in a male population.Circulation1988;78:1380–1387.
38.
HannhartB, MichalskiH, DelormeN, ChapparoG, PoluJM. Reliability of six pulse oximeters in chronic obstructive pulmonary disease.Chest1991;99:842–846.
PraudJP, CarofilisA, BridleyF, DehanM, GaultierCL. Accuracy of two wavelength pulse oximetry in neonates and infants.Pediatr Pulmonol1989;6:180–182.
41.
ECRI Health Devices Alert, 1990-A26. Plymouth Meeting PA, ECRI, June 29, 1990.
42.
WangerJ, editor. ATS pulmonary function laboratory management and procedure manual. New York: American Thoracic Society; 1998; Ch 17,18.
43.
JensenLA, OnyskiwJE, PrasadNGN. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults.Heart Lung1998;27(6):387–408.
44.
TweeddaleP, DouglasN.Evaluation of Biox Ila ear oximeter.Thorax1985;40:825–827.
45.
MoyleJTB. Principles and practice series: pulse oximetry. London: BMJ Books; 1998.
46.
MorrisRW, NairnM, TordaTA. A comparison of fifteen pulse oximeters. Part I: a clinical comparison; Part II: a test of performance under conditions of poor perfusion.Anaesth Intensive Care1989;17:62–82.
47.
WilliamsJ, PowersS, StuartM.Hemoglobin desaturation in highly trained endurance athletes during heavy exercise.Med Sci Sports Exerc1986;18:168–173.
48.
GodfreyS, WozniakER, Courtney-EvansRJ, SamuelsCS. Ear lobe blood samples for blood gas analysis at rest and during exercise.Br J Dis Chest1971;65:58–65.
49.
MartinD, PowersS, CicaleM, CollopN, HuangD, CriswellD.Validity of pulse oximetry during exercise in elite endurance athletes.J Appl Physiol1992;72(2):455–458.
50.
WarleyAH, MitchellJH, StradlingJR. Evaluation of the Ohmeda 3700 pulse oximeter.Thorax1987;42:892–896.
PoetsCF, StebbensVA. Detection of movement artifact in recorded pulse oximeter saturation.Eur J Pediatr1997;156(10):808–811.
53.
SeveringhausJW, KohSO. Effect of anemia on pulse oximeter accuracy at low saturation.J Clin Monit1990;6:85–88.
54.
BlonshineS, AlbertiR, OlesinskiRL. NCCLS H11-A3, 3rd ed. Procedures for the collection of arterial blood specimens: approved standard. May 1999;19(8). Available from NCCLS: phone 610-688-0100; Fax 610-688-0700; e-mail exoffice@nccls.org.
55.
NCCLS. GP26-AA quality system model for health care: approved guideline (1999). Available from NCCLS: phone 610-688-0100; Fax 610-688-0700; e-mail exoffice@nccls.org.
56.
NCCLS. HS4-AA quality system model for respiratory care. Available from NCCLS: phone 610-688-0100; Fax 610-688-0700; e-mail exoffice@nccls.org.
57.
European Respiratory Society. Clinical exercise testing with reference to lung diseases: indications, standardization and interpretation strategies. ERS Task Force on Standardization of Clinical Exercise Testing.Eur Respir J1997;10(11):2662–2689.
58.
MorganMDL. Exercise testing. In: HughesJMB, PrideNB editors. Lung function tests: physiological principles and clinical applications. Philadelphia: WB Saunders; 1999.
59.
LearSA, BrozicA, MyersJN, IgnaszewskiA.Exercise stress testing: an overview of current guidelines.Sports Med1999;27(5):285–312.
60.
MartinTW, ZeballosRJ, WeismanIM. Use of arm crank exercise in the detection of abnormal pulmonary gas exchange in patients at low altitude.Chest1992;102:169–175.
61.
MartinTW, ZeballosRJ, WeismanIM. Gas exchange during maximal upper extremity exercise.Chest1991;99:420–425.
62.
BorgGAV. Psycho-physical basis of perceived exertion.Med Sci Sports Exercise1982;14:377–381.
63.
BorgGA. Borg's perceived exertion and pain scales. Champaign: Human Kinetics; 1998.
64.
StephensJM. Walking speed on parquetry and carpet after stroke: effect of surface and retest reliability.Clin Rehabil1999;13:171–181.
65.
AitkenRCB. Measurement of feelings using visual analogue scales.Proc R Soc Med1969;62:989–993.
66.
GarnerJS. Hospital Infection Control Practices Advisory Committee, Centers for Disease Control and Prevention. Guidelines for isolation precautions in hospitals. Atlanta GA: Centers for Disease Control and Prevention, 1-01-1996. www.cdc.gov or Am J Infect Control1996;24(1):24–52.
67.
Centers for Disease Control and Prevention, Hospital Infection Control Practices Advisory Committee. Guideline for infection control in health care personnel, 1998.Am J Infect Control1998;26:269–354 or Infect Control Hosp Epidemiol 1998;19:407–463.
68.
LarsonEL. APIC guideline for handwashing and hand antisepsis in health care settings.Am J Infect Control1995;23(4):251–269.
69.
Centers for Disease Control & Prevention. Guidelines for preventing the transmission of tuberculosis in health-care facilities. 1994.MMWR 1994;43(RR-13):1–32 or Federal Register 1994;59(208):54242–54303 or http://aepo-xdv-www.epo.cdc.gov/wonder/prevguid/m0035909/m0035909.htm.
ZavalaD.Manual on exercise testing, 2nd ed. Iowa City: University of Iowa Press; 1987.
72.
FletcherGF, BaladyG, FroelicherVF, HartleyLH, HaskellWL, PollockML. Exercise standards: a statement for health professionals from the American Heart Association.Special Report. Circulation1995;91:580–615.
73.
AstrandPO, RodahlK.Textbook of work physiology, 2nd ed. McGraw-Hill; 1977.
74.
EllestadMH, BlomquistCG, NaughtonJP. Standards for adult exercise testing laboratories.Circulation1979;59 (Suppl):421A–430A.