MooreEW. Studies with ion-exchange calcium electrodes in biological fluids. In: DurstRA, ed. Ion Selective Electrodes. National Bureau of Standards Special Publication No. 314. Washington: NBS, 1969; 215–85.
2.
Siggaard-AndersenOThodeJWandrupJ.The concentration of free calcium ions in the blood plasma: ‘ionised calcium’. In: Siggaard-AndersenO, ed. Blood pH, Carbon Dioxide, Oxygen and Calcium Ion.Copenhagen: Radiometer, 1981; 163–90.
3.
Fogh-AndersenN. Albumin/calcium association at different pH as determined by potentiometry. Clin Chem1977; 23: 2122–6.
4.
PedersenKO. Binding of calcium to serum albumin. I. Stoichiometry and intrinsic association constant at physiological pH, ionic strength and temperature. Scand J Clin Lab Invest1971; 28: 459–69.
5.
PedersenKO. Protein bound calcium in human serum. Quantitative examination of binding and its variables by a molecular binding model and clinical chemical implications for measurement of ionized calcium. Scand J Clin Lab Invest1972; 30: 321–9.
6.
LadensonJHShyongJC. Influence of fatty acids on the binding of calcium to human serum albumin. Clin Chim Acta1977; 75: 293–302.
7.
HeiningMPDBandDMLintonRAF. The effect of temperature on plasma ionized calcium measured in whole bloodin vitro. Scand J Clin Lab Invest1983; 43: 709–709.
8.
Fogh-AndersenNFalch-ChristiansenTKomarmyLSiggaard-AndersenO. Measurement of free calcium ion in capillary blood and serum. Clin Chem1978; 24: 1545–52.
9.
ThodeJFogh-AndersenNWimberleyPDRelation between pH and ionized calcium in vitro and in vivo in man. Scand J Clin Lab Inves.1983; 43 (Suppl 165): 79–82.
10.
LudbrookJWynnV. Citrate intoxication: a clinical and experimental study. Br Med J1958; 2: 523–8.
11.
GrayTABuckleyBMSealeyMPlasma ionized calcium monitoring during liver transplantation. Transplantation1986; 41: 335–9.
12.
McLeanFCHastingsAB. A biological method for the estimation of calcium ion concentration. J Biol Chem1934; 107: 337–50.
13.
McLeanFCHastingsAB. The state of calcium in the fluids of the body. 1. The conditions affecting the ionization of calcium. J Biol Chem1935; 108: 285–322.
14.
McLeanFCHastingsAB. Clinical estimation and significance of calcium ion concentration in the blood. Am J Med Sci1935; 189: 601–13.
15.
SchachterDDowdleEBSchenkerH. Active transport of calcium by the small intestine of the rat. Am J Physiol1960; 198: 263.
16.
WalserM. Ion association VI. Dependence of calciuresis on natriuresis during sulfate infusion. Am J Physiol1961; 201: 769.
17.
SherwoodLMPottsJTCareADEvaluation by radioimmunoassay of factors controlling the secretion of parathyroid hormone. Nature (Lond)1966; 209: 52.
18.
ChenIWParkHMKingLRRadioimmunoassay of parathyroid hormone: peripheral plasma immunoreactive parathyroid hormone response to ethylenediaminetetraacetate. J Nucl Med1974; 15: 763.
19.
TorringOSjobergHE. An ionised calcium regulated calcium clamp technique in man. Scand J Clin Lab Invest1983; 43 (Suppl 165): 101–4.
20.
RasmussenH. The cellular basis of mammalian calcium homeostasis. Clinics Endocrinol Metab1972; 1: 3.
21.
KahnRCJascottDCarlsonGCMassive blood replacement. Correlation of ionized calcium, citrate and hydrogen ion concentration. Anaesth Analg1979; 58: 274–8.
22.
DropLJGeffinGAO'KeefeDDRelation between ionized calcium concentration and ventricular pump performance in the dog under hemodynamically controlled conditions. Am J Cardiol1981; 47: 1041–51.
23.
KugimiyaTDropLJEwalenkoP. Mechanical performance of the working rat heart: response to calcium. J Surg Res1982; 32: 57–64.
24.
AuffantRADownsJB. Ionized calcium and cardiovascular function after cardiopulmonary bypass. Arch Surg1981; 116: 1072–6.
25.
SeamondsBTowfighiJArvanDA. Determination of ionized calcium in serum by use of an ion selective electrode. Clin Chem1972; 18: 155–8.
26.
BuckleyBMSmithSCHHeathDABoldAM. Clinical studies on ionized calcium using the Radiometer ICA1 analyser. Scand J Clin Lab Invest1983; 43 (Suppl 165): 87–92.
27.
ArverSSjobergHE. Ionized calcium in human seminal plasma. Scand J Clin Lab Invest1983; 43 (Suppl 165): 123–6.
28.
RodanGALibermanUAParanMAnbarM. Lack of physicochemical equilibrium between blood and bone calcium in the isolated perfused dog limb. Israel J Med Sci1967; 3: 702–9.
29.
WortsmanJTraycoffRB. Biological activity of protein-bound calcium in serum. Am J Physiol1980; 238: E104.
30.
ToffalettiJBowersGN. The possible physiologic importance of calcium complexes: an opinion. Clin Chim Acta1979; 97: 101–5.
31.
YendtERConnorTBHowardJE. In vitro calcification of rachitic rat cartilage in normal and pathological human sera, with some observations on the pathogenesis of renal rickets. Bull Johns Hopkins Hosp1955; 96: 1–19.
32.
SoulierJPCrosnierJ. Nouvelle methode de dosage du calcium ionise utilisant un systeme coagulant. Rev Fr Etud Clin Biol1958; 3: 157–8.
33.
FrizelDEMallesonAGMarksV. Measurement of plasma ionised calcium and magnesium by ion exchange strip. Clin Chim Acta1967; 16: 45–56.
GoslingP. Analytical methods in clinical biochemistry: the measurement of calcium. Ann Clin Biochem1986; 23: 146–56.
36.
RaaflaubJ. Uber ein photometrisches verfahren zur Bestimmung des ionisierten Calciums. Z Physiol Chem1951; 228: 228–36.
37.
RoseGA. Determination of the ionised and ultrafiltrable calcium of normal human plasma. Clin Chim Acta1957; 2: 227–36.
38.
PedersenKO. Determination of calcium fractions in serum II. Investigations of calcium ion activity and stability of important calcium complexes by an improved semimicro method. Scand J Clin Lab Invest1970; 25: 199–208.
39.
VargheseZ. Determination of plasma calcium fractions. Ann Clin Biochem1973; 10: 120–4.
40.
HarnachFCoolidgeTB. Determination of ionized calcium in serum with murexide. Anal Biochem1963; 6: 477–85.
41.
RaaflaubJ. Applications of metal buffers and metal indicators in biochemistry. Meth Biochem Anal1956; 3: 301–25.
42.
RaaflaubJ. Zur photomitrischen bestimmung des ionisierten calciums in biologischen flussigkeiten, insbesondere im harn. Z Physiol Chem1962; 328: 198–203.
43.
RobertsonWG. Measurement of calcium in biological fluids. Clin Chim Acta1969; 24: 149–57.
44.
SarisN-ELAllshireAAkermanKEO. Measurement of calcium in the micro- and sub-micromolar range. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 23–39.
45.
ScarpaABrinleyFJTiffertTDubyakGR. Metallochromic indicators of ionized calcium. Ann N Y Acad Sci1978; 307: 86–112.
46.
TsienRY. New calcium indicators and buffers with high selectivity against magnesium and protons: design, synthesis and properties of prototype structures. Biochemistry1980; 19: 2396–404.
47.
GrynkiewiczGPoenieMTsienRY. A new generation of Ca2+ indicators with greatly improved fluorescence properties. J Biol Chem1985; 260: 3440–50.
48.
BlinksJR. Measurement of calcium ion concentrations with photoproteins. Ann N Y Acad Sci1978; 307: 71–85.
TendelooHJC. A new and easy method for the potentiometric determination of calcium concentrations in solutions. J Biol Chem1936; 113: 333–9.
51.
JosephNR. Heterogeneous equilibrium of protein solutions II. The interaction of calcium chloride and other salts with proteins as determined by a new type of calcium amalgam electrode. J Biol Chem1938; 126: 389–405.
52.
CarrCW. Studies on the binding of small ions in protein solutions with the use of membrane electrodes. II. The binding of calcium ions in solutions of bovine serum albumin. Arch Biochem Biophys1953; 43: 147–56.
53.
GregorHPSchonhornH. Multilayer membrane electrodes II. Preparation and use in double concentration cells. J Am Chem Soc1959; 81: 3911–5.
54.
ShatkayA. Ion specific membranes as electrodes in determination of the activity of calcium. Anal Chem1967; 39: 1056–65.
55.
RossJW. Calcium selective electrode with liquid ion exchanger. Science1967; 156: 1378–9.
56.
FerreiraPBoldAM. Clinical laboratory evaluation of the Orion SS-20 ionized calcium analyser. J Autom Chem1979; 1: 94–102.
57.
MadsenSOlgaardK. Evaluation of a new automatic calcium ion analyser. Clin Chem1977; 23: 690–4.
58.
BowersGNBrassardCSenaSF. Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs. Clin Chem1986; 32: 1437–47.
59.
AmmannDPretchESimonW. A calcium ion-selective electrode based on a neutral carrier. Anal Lett1972; 5: 843–50.
60.
AmmannDPretchESimonW. Darstellung von neutralen, lipophilen Liganden fur Membrane-lektroden mit Selektivitat fur Erdalkali-Ionen. Helv Chim Acta1973; 56: 1780–7.
61.
RuzickaJHansenEHTjellJC. Selectrode—the universal ion-selective electrode. Part IV. The calcium (II) Selectrode employing a new ion exchanger in a non-porous membrane and a solid-state reference system. Anal Chim Acta1973; 67: 155–78.
FreiserH, ed. Ion-Selective Electrodes in Analytical Chemistry.Vols 1, 2. New York: Plenum Press, 1979, 1980.
64.
KorytaJ, ed. Medical and Biological Applications of Electrochemical Devices.New York: John Wiley, 1980.
65.
HirstADStevensJF. Electrodes in clinical chemistry. Ann Clin Biochem1985; 22: 460–88.
66.
OeschUAmmannDSimonW. Ion-selective electrodes for clinical use. Clin Chem1986; 32: 1448–59.
67.
SimonWAmmannDOehmeMMorfWE. Calcium-selective electrodes. Ann N Y Acad Sci1978; 307: 52–70.
68.
EisenmanG.Theory of membrane electrode potentials. In: DurstRA, eds. Ion Selective Electrodes. National Bureau of Standards Special Publication No. 314. Washington: NBS, 1969; 1–56.
69.
KimuraKKumamiKKitazawaSShonoT. Enhanced calcium selectivity of a macrocyclic polyetheramide with two polyether rings. J Chem Soc Chem Commun1984; 17: 442–3.
70.
RossJW. Solid-state and liquid membrane electrodes. In: DurstRA, ed. Ion Selective Electrodes. National Bureau of Standards Special Publication No. 314. Washington: NBS, 1969; 57–88.
71.
MeierPCAmmannDMorfWESimonW.Liquid-membrane ion-selective electrodes and their biomedical applications. In: KorytaJ, ed. Medical and Biological Applications of Electrochemical Devices.New York: John Wiley, 1980: 13–91.
72.
PretschEWegmannDAmmannDEffects of lipophilic charged sites on the electromotive behaviour of liquid membrane electrodes. In: KesslerM, eds. Ion Measurements in Physiology and Medicine.Berlin: Springer, 1985; 11–16.
73.
CovingtonAK. Reference electrodes. In: DurstRA, ed. Ion Selective Electrodes. National Bureau of Standards Special Publication No. 314. Washington: NBS, 1969; 57–88.
74.
ChristiansenTF. The Achilles' heel of potentiometric measurements, the liquid junction potential. IEEE Trans Biomed Engin1986; BME–33: 79–82.
75.
Siggaard-AndersenO.The Acid-Base State of the Blood.Copenhagen: Munksgaard1974.
76.
SimpsonRJ. Practical techniques for ion-selective electrodes. In: CovingtonAK, ed. Ion-Selective Electrode Methodology, Vol I. Boca Raton: CRC Press1979: 58–62.
77.
Siggaard-AndersenO. Factors affecting the liquid-liquid junction potential in electrometric blood pH measurement. Scand J Clin Lab Invest1961; 13: 205–11.
78.
McKinleyBAWongKCJanataJIn vivo continuous monitoring of ionized calcium in dogs using ISFETs. Crit Care Med1981; 9: 333–9.
79.
SibbaldACovingtonAKCarterRF. Simultaneous on-line measurement of blood K+, Ca2+, Na+ and pH with a four-function ChemFET integrated-circuit sensor. Clin Chem1984; 30: 135–7.
80.
CovingtonAKSibbaldA.Microelectronic chemical sensors for clinical analysis. In: KochWF, ed. Direct Potentiometric Measurements in Blood.Villanova: National Committee for Clinical Laboratory Standards1985: 81–95.
81.
McKinleyBAHoutchensBAJanataJ. In vivo application of ISFETs: summary of current laboratory research and probable future detectors. Ion-Selective Electrode Rev1984; 6: 173–208.
82.
FreiserH.Coated wire ion-selective electrodes. In: FreiserH, ed. Ion-Selective Electrodes in Analytical ChemistryVolume 2. New York: Plenum, 1980; 85–106.
83.
AnkerPWielandEAmmanDNeutral carrier based ion-selective electrode for the determination of total calcium in blood serum. Anal Chem1981; 53: 1970–4.
84.
MarsonerHJRitterCOdarW.Indirect potentiometric determination of total calcium in plasma. In: MaasAHJ, eds. Ionized Calcium, Sodium and Potassium by Ion Selective Electrodes.Copenhagen: Radiometer1984: 105–14.
85.
MalenfantALYoungCCMcHaleJF. Total calcium in serum and urine by ISE measurements. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 149–50.
86.
ManzoniAPremoliP.Determination of total calcium in serum using ISE. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 131–48.
87.
BoinkABTGimpelJAMaasAHJ. A comparison of four Ca2+ analysers. Scand J Clin Lab Invest1983; 43 (Suppl 165): 17–19.
88.
BowersGN. A reference system for ionized calcium. Scand J Clin Lab Invest1983; 43 (Suppl 165): 49–56.
89.
CovingtonAKFerraMIA. Calculation of single ion activities in solutions simulating blood plasma. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 239–47.
DurstRA, ed. Standard Reference Materials: Standardisation of pH Measurement. National Bureau of Standards Special Publication No. 260/53. Washington: NBS, 1975; 1–38.
92.
BoinkAHJBuckleyBMChristiansenTFReference method for determination of ionized calcium in serum, plasma or whole blood. In: MaasAHJ eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 239–47.
93.
BowersGNBurnettRWSenaSFChristiansenTF. Observations on primary reference solutions for ionized calcium. A study of systematic bias due to calcium binding to buffer and to residual liquid junction potentials. In: MaasAHJ eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 49–54.
94.
SenaSFBurnettRWBowersGN. Reference solutions for ionized calcium measurements: calcium-buffer association and liquid junction effects. Clin Chem1988 (in press).
95.
MaasAHJWeisbergHFZijlstraWGReference for pH measurement in blood. J Clin Chem Clin Biochem1983; 21: 313–21.
96.
Fogh-AndersenN. Ionized calcium analyser with a built-in pH correction. Clin Chem1981; 27: 1264–7.
97.
SmithSCHBuckleyBMWedgeGBoldAM. An evaluation of the ICA1 ionized calcium analyser in a clinical chemistry laboratory. Scand J Clin Lab Invest1983; 43 (Suppl 165): 33–7.
98.
WandrupJKvetnyJ.Potentiometric measurements of ionized calcium in anaerobic whole blood, plasma and serum evaluated. Clin Chem1985; 856–60.
99.
RenoBWMcDonaldJMLadensonJM. Influence of posture on free calcium and related variables. Clin Chem1979; 25: 1766–9.
100.
NielsenSPChristiansenTFHartlingOTrap-JensenJ. Increase in serum ionized calcium during exercise. Clin Sci Mol Med1977; 53: 579–86.
101.
RenoeBWMcDonaldJMLadensonJH. The effect of stasis with and without exercise on free calcium, various cations and related parameters. Clin Chim Acta1980; 103: 91–100.
102.
SachsChBourdeauAMBalsanS. Determination du calcium ionise dans le serum avec une electrode specifique a membrane liquide. Ann Biol Clin1969; 27: 487–509.
103.
SachsChThodeJ. Preanalytical errors in ionized calcium determination in blood: a review for a subsequent recommendation for sampling. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 49–54.
104.
BoinkABTBuckleyBMChristiansenTFRecommendations on blood sampling, transport and storage for the determination of the substance concentration of ionized calcium. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes II.Copenhagen: International Federation of Clinical Chemistry, 1987; 81–8.
105.
BuckleyBMRawsonKMRussellLJ. Effect of hemolysis on ionized calcium determination in blood plasma. In: MoranR, eds. Ion Selective Electrodes.Washington: NCCLS, 1988 (in press).
106.
UrbanPBuchmannBScheideggerD. Facilitated determination of ionized calcium. Clin Chem1985; 31: 264–6.
107.
NikolakakisNIDe FranciscoAMRodgerRSCEffect of storage on measurement of ionized calcium in serum of uremic patients. Clin Chem1985; 31: 287–9.
108.
BuckleyBMSmithSCH. Some factors influencing the quality of ionised calcium measurements. In: MaasAHJ, eds. Ionized Calcium, Sodium and Potassium by Ion Selective Electrodes.Copenhagen: Radiometer1984: 49–54.
109.
PayneRB. Carryover between internal standards in the Nova 2 ionized calcium analyser. Clin Chem1981; 27: 1956–7.
110.
ButlerSJPayneRB. Nova 2 ionized calcium analyser: imprecision, bias, and protein interference. Clin Chem1983; 29: 585–6.
111.
SeveringhausJWStupfelMBradleyAF. Accuracy of blood pH and PCO2 determinations. J Appl Physiol1956; 9: 189–96.
112.
MaasAHJ. pH determinations of body fluids with a micro glass electrode and a saturated KCl bridge in the cell. Clin Chun Acta1970; 28: 373–90.
113.
CormierADCzabanJDFejesAM. Whole blood-plasma bias introduced at the liquid junction in direct potentiometry. In: MaasAHJ eds. Ionized Calcium Sodium and Potassium by Ion Selective Electrodes.Copenhagen: Radiometer1984; 105–114.
114.
BatesRG. Determination of pH, Theory and Practice, 2nd Ed.New York: Wiley, 1973.
115.
PedersenKO. The effect of protein concentration on potentiometric determination of ions in serum and blood. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 77–98.
116.
Siggaard-AndersenOFogh-AndersenNThodeJ.Elimination of the erythrocyte effect on the liquid junction potential in potentiometric measurements on whole blood using mixed salt bridge solutions. Scand J Clin Lab Invest1983; 43 (Suppl 165): 43–6.
117.
BoinkABTSprokholtRMaasAHJOccurrence and possible mechanism of Mg2+ interference on the ICA-1. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 123–31.
118.
KaufmanRATietzNW. Ion effects in measurement of ionized calcium with a calcium-selective electrode. Clin Chem1980; 26: 640–4.
119.
OeschUAmmannDSimonW.Use of ISEs for clinical analysis: past and future. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 123–31.
120.
PedersenKO. Determination of calcium fractions in serum. I. The separation of protein-bound and protein-free fractions by means of a simplified ultrafiltration technique. Scand J Clin Lab Invest1969; 24: 69–81.
121.
PayneRB. Clinically significant effect of protein concentration on ion-selective electrode measurements of ionised calcium. Ann Clin Biochem1982; 19: 233–7.
122.
ButlerSJPayneRB. Nova ionized calcium analyser: imprecision, bias and protein interference. Clin Chem1983; 29: 585–6.
123.
PayneRBJonesDP. Protein interferes with ionized calcium measurement at the reference electrode liquid junction. Ann Clin Biochem1987; 24: 400–7.
124.
FreaneyREganTMcKennaMJDetermination of ionised calcium by ion selective electrode is not independent of albumin concentration. Clin Chim Acta1986; 158: 129–38.
125.
Fogh-AndersenNThodeJSiggaard-AndersenO.Ionized calcium during dialysis and ultrafiltration. Scand J Clin Lab Invest1983; 43 (Suppl 165): 39–43.
126.
ThodeJFogh-AndersenNSiggaard-AndersenO. Ionized calcium and the Donnan effect. Clin Chem1983; 29: 1554–5.
127.
ButlerSJPayneRBGunnIRCorrelation between serum ionized calcium and albumin concentrations in two hospital populations. Br Med J1984; 289: 948–50.
128.
BuckleyBMRawsonKRussellLJ. Protein does not interfere with ISE determinations of Na+ or Ca2+: a demonstration using cells ‘without liquid junctions’. In: MaasAHJBuckleyBMMarsonerH eds. Methodology and Clinical Applications of Ion Selective Electrodes II. Copenhagen: International Federation of Clinical Chemistry, 1987; 8: 299–299.
129.
BourdeauAM. Contribution a l'etude du dosage du calcium ionise dans le sang par une electrode a membrane liquide. PhD thesis: Universite Rene Descartes de Paris1972.
130.
LarssonLOhmanS.Experiences with internal quality controls for serum ionized calcium. In: MaasAHJ, eds. Ionized Calcium, Sodium and Potassium by Ion Selective Electrodes.Copenhagen: Radiometer1984: 155–64.
131.
SprokholtRBoinkABTMaasAHJ. Feasibility test of proposed calibration solutions on commercial ISE instruments. In: MaasAHJ, eds. Methodology and Clinical Applications of Ion Selective Electrodes.Copenhagen: International Federation of Clinical Chemistry, 1986; 171–84.
132.
DropLJMisianoDRTochkaLN. Commercial protein-containing solutions for quality assurance of Ca2+ measurement. Clin Chem1982; 28: 2448.
133.
FyffeJAJenkinsASBollandCJPreparation of material to control precision of calcium selective electrodes. Ann Clin Biochem1981; 18: 110–1.
134.
FyffeJA. A readily available source of serum for use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes. J Autom Chem1982; 4: 79.
135.
LarssonLOhmanS. Nova 2 ionized calcium analyzer compared with the Orion SS-20. Clin Chem1980; 26: 1761–3.
136.
UldallAFogh-AndersenNThodeJQuality assessment of the determinations of ionized calcium with ion selective electrodes. In: MaasAHJ, eds. Ionized Calcium, Sodium and Potassium by Ion Selective Electrodes.Copenhagen: Radiometer1984: 165–72.
137.
GrayTAPatersonCR. The clinical value of ionised calcium assays. Ann Clin Biochem1988; 25: 210–19.