CohenDB. Uremia: International Conference on Pathogenesis, Diagnosis and Therapy. Stuttgart: Springer-Verlag, 1971.
6.
BoroujerdiMMattocksAM. Metabolism of creatinine in vivo. Clin Chem.1983; 29: 1363–6.
7.
OwensCWIAlbuquerqueZDTomlinsonGM. In vitrometabolism of creatinine, methylamine and amino acids by intestinal contents of normal and uraemic subjects. Gut1979; 20: 568–74.
8.
BarsottiABevilacquaGMorelliE, Toxicity arising from guanidine compounds: Role of methylguanidine as a uremic toxin. Kidney Int.1975; 7: 5299–301.
BowersLDWongET. Kinetic serum creatinine assays: II A critical evaluation and review. Clin Chem.1980; 26: 555–61.
11.
MitchellFLVeallNWattsRWE. Renal function tests suitable for clinical practice. Ann Clin BioChem.1972; 9: 1–20.
12.
KafetzK. Renal impairment in the elderly: a review. J Roy Soc Med.1983; 76: 398–402.
13.
KampmannJSiersbaek-NielsenKKristensenM, Rapid evaluation of creatinine clearance. Acta Med Scand.1974; 196: 517–20.
14.
BennettWMSingerICogginsCJ. A guide to drug therapy in renal failure. J Am Med Ass.1974; 230: 1544–53.
15.
JelliffeRW. Estimation of creatinine clearance when urine cannot be collected. Lancet.1971; i: 975–6.
16.
Siersbaek-NielsenKHansenJ MolholmKampmannJ, Rapid evaluation of creatinine clearance. Lancet.1971; i: 1133–4.
17.
DoolanPDAlpenELTheilGB. A clinical appraisal of the plasma concentration and endogenous clearance of creatinine. Am J Med.1962; 32: 65–79.
18.
MitchWEBuffingtonGAWalserM, A simple method of estimating progression of chronic renal failure. Lancet.1976; ii: 1326.
19.
RutherfordWEBlondinJMillerJP, Chronic prognosis of renal disease; rate of change of serum creatinine concentration. Kidney Int.1977; 11: 62–70.
20.
TobiasGJMcLaughlinRFHooperJ. Endogenous creatinine clearance. N Engl J Med.1962; 266: 317–23.
21.
MorganDBDillonSPayneRR. The assessment of glomerular function: creatinine clearance or plasma creatinine?Postgrad Med J1978; 54: 302–10.
22.
RosanoTGBrownHH. Analytical and biological variability of serum creatinine and creatinine clearance: Implications for interpretation. Clin Chem.1982; 28: 2330–1.
23.
FolinO. Approximately complete analysis of thirty ‘normal urines’. Am J Physiol.1905; 13: 45–65.
24.
PatersonN. Relative constancy of 24 hour urine volume and 24 hour creatinine output. Clin Chim Acta1967; 18: 57–8.
25.
ScottPJHurleyPJ. Demonstration of individual variation in constancy of 24 hour urinary creatinine excretion. Clin Chim Acta1968; 21: 411–4.
StatlandBEWinkelP. Effects of pre-analytical factors on the intra individual variation of analytes in the blood of healthy subjects. Consideration of preparation of the subject and time of venipuncture. Crit Rev Clin Lab Sci.1977; 8: 105–44.
28.
WinkelPBokelundHStatlandBE. Factors contributing to intra individual variation of serum constituents. 5. Short term day-to-day and within-hour variation of serum constituents in healthy subjects. Clin Chem.1974; 20: 1520–7.
29.
WinkelPStatlandBEBokelundH. The effects of time of venipuncture on variation of serum constituents: consideration of within-day and day-to-day changes in a group of healthy young men. Am J Clin Path1975; 64: 433–47.
30.
YoungDSHarrisEKCotloveE. Biological and analytical components of variation in long term studies of serum constituents in normal subjects. IV. Results of a study designed to eliminate long term analytical deviations. Clin Chem.1971; 17: 403.
31.
CotloveEHarrisEKWilliamsGZ. Biological and analytical components of variation in long term studies of serum constituents in normal subjects. III. Physiological and medical implications. Clin Chem.1970; 16: 1028–32.
32.
TonksDB. A study of the accuracy and precision of clinical chemistry determinations in 170 Canadian laboratories. Clin Chem.1963; 9: 217–23.
33.
ElevitchFR. Proceedings of the 1976 Aspen Conference on Analytical Goals in Clinical Chemistry. Illinois: C.A.P., 1977.
34.
ElevitchFR. Analytical goals in clinical chemistry: Their relationship to medical care. A J Clin Path1979; 71: 624–30.
JaffüM. Ueber den Neiderschlag, welchen Pikrinsaeure in normalen Harn erzeugt and ueber eine neue Reaktion des Kreatinins. Z Physiol Chem.1986; 10: 391–400.
39.
FolinO. Beitrag zur Chemie des Kreatinins und Kreatins in Harne. Z Physiol Chem.1904; 41: 223–4.
40.
FolinO. On the determination of creatinine and creatine in blood, milk and tissues. J Biol Chem.1914; 17: 475–81.
41.
GreenwaldI. Chemistry of Jaffé's reaction for creatinine. II. The effect of substitution in the creatinine molecule and a possible formula for the red tautomer. J Am Chem Soc.1925; 47: 1443–7.
42.
GreenwaldIGrossJ. The chemistry of Jaffé's reaction for creatinine. A red tautomer of creatinine picrate. J Biol Chem.1925; 59: 601–12.
43.
GreenwaldI. The chemistry of Jaffé's reaction for creatinine. 5. The isolation of the red compound. J Biol Chem.1928; 80: 103–6.
44.
GoldVRochesterCH. Reactions of aromatic nitro compounds in alkaline media. VII. Behaviour of picric acid and of two dihydroxydini-trobenzenes in aqueous sodium hydroxide. J Chem Soc.1964; 20: 1722–7.
45.
ButlerAR. The Jaffé reaction. Identification of the coloured species. Clin Chim Acta1975; 59: 227–32.
46.
ButlerAR. The Jaffé reaction. II. A kinetic study of the Janovsky complexes formed from creatinine (2-imino-1-methylimazolidin-4-one) and acetone. J Chem Soc (Perkin Trans)1975; 2: 853.
47.
VasiliadesJ. Reaction of alkaline sodium picrate with creatinine; 1. Kinetics and mechanism of formation of the mon creatinine picric acid complex. Clin Chem.1976; 22: 1664–71.
48.
GreenwaldIMcGuireG. The estimation of creatinine and creatine in the blood. J Biol Chem.1918; 34: 103–18.
49.
GaeblerO. Further studies of blood creatinine. J Biol Chem.1930; 89: 451.
50.
BorsookH. Micromethods for determination of ammonia, urea, total nitrogen, uric acid, creatinine (and creatine) and allantoin. J Biol Chem.1935; 110: 481.
51.
OwenJAIgooBScandrettFJ, The determination of creatinine in plasma or serum, and urine; a critical examination. Biochem J1954; 58: 426–37.
52.
HaeckelR. Assay of creatinine in serum, with use of Fuller's Earth to remove interferents. Clin Chem.1981; 27: 179–83.
53.
KanturekVPalovskyVSonkaJ. Specificity of the Lloyd reagent for the estimation of creatinine in serum. Cas Lek Cesk1954; 93: 435–6.
54.
KnollEStammD. The specific determination of serum creatinine. J Clin Chem Clin BioChem.1970; 8: 582–7.
55.
PolarEMetcoffJ. True creatinine chromogen determination in serum and urine by semi-automated analysis. Clin Chem.1965; 11: 763–70.
56.
Teger-NilssonAC. Serum creatinine determination using an ion exchange resin. Scand J Clin Lab Invest1961; 13: 326–31.
57.
RockerbieRARasmussenKL. Rapid determination of serum creatinine by an ion exchange technique. Clin Chim Acta1967; 15: 475–9.
58.
MitchellRJ. Improved method for specific determination of creatinine in serum and urine. Clin Chem.1973; 19: 408–10.
59.
WeatherburnMWTrotmanRBBJacksonSH. Specific method for serum creatinine determination based on Ion Exchange Chromatography and an automated alkaline picrate reaction—a proposed Reference Method. Clin BioChem.1978; 11: 159–66.
60.
AdamsWSDavisFWHansenLE. New method for determination of creatinine in urine by ion exchange separation and ultraviolet spectrophotometry. Anal BioChem.1962; 34: 854–6.
61.
McEvoy-BoweE. Determination of creatinine in urine by separation on DEA-Sephadex and ultraviolet spectrophotometry. Anal BioChem.1966; 16: 153–9.
62.
AdamsWSDavisFWHansenLE. Determination of serum creatinine by ion exchange chromatography and ultraviolet spectrophotometry. Anal Chem.1964;; 36: 2209–11.
63.
KostirJVSonkaT. Creatinine estimation in blood serum. A new method. Biochem Biophys Acta1950; 8: 86–9.
64.
SlotC. Plasma creatinine determination. A new and specific Jaffé reaction method. Scand J Clin Lab Invest1965; 17: 381–7.
65.
TausskyHH. A microcolorimetric determination of creatinine in urine by the Jaffé reaction. J Biol Chem.1954; 208: 853–61.
66.
TausskyHH. A procedure for increasing the specificity of the Jaffé reaction for the determination of creatine and creatinine in urine and plasma. Clin Chim Acta1956; 1: 210–24.
67.
CookJGH. Factors influencing the assay of creatinine. Ann Clin BioChem.1975; 12: 219–32.
68.
GraffnetterDJanosovaZCervinkovaI. Note on Slot's method for the specific determination of creatinine. Clin Chim Acta1967; 17: 493–8.
69.
HeinegardDTiderstromG. Determination of serum creatinine by a direct colorimetric method. Clin Chim Acta1973; 43: 305–10.
70.
Van StekelenburgGJValkCVan de KampJS, A new automated method for the determination of true creatinine in serum by means of the Centrifichem centrifugal analyser, based on Slot's principle, with special reference to low substrate concentrations. Clin Chim Acta1978; 89: 79–91.
71.
LolekhaPHChantarothipolVWongvibulsinA. New continuous flow analysis for simultaneous determination of creatinine and uric acid in 200 μL of serum without use of a dialyser. Clin Chem.1978; 24: 1578–85.
72.
LolekhaPHTaksinamaneeR. Evaluation of serum creatinine measurements by the direct acidification method for errors contributed by non creatinine chromogens. Clin Chim Acta1980; 107: 97–104.
73.
RaaboEWalloe-HansenP. A routine method for determining creatinine avoiding deproteinisation. Scand J Clin Lab Invest1972; 29: 297–301.
74.
YatzidisH. New method for direct determination of ‘True’ creatinine. Clin Chem.1974; 20: 1131–4.
75.
ChassonALGradyHJStanleyMA. Determination of creatinine by means of automatic analysis. Am J Clin Path1961; 35: 83–8.
76.
PardueHL. A comprehensive classification of kinetic methods of analysis used in clinical chemistry. Clin Chem.1977; 23: 2189–201.
77.
RenoeBWSavoryJCrossRE. Kinetic versus equilibrium methods of analysis. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 157–69.
78.
TiffanyTOThayerPCCoelhoCM, A propagation of error analysis of the enzyme activity expression. A model for determining the total system random error of a kinetic analyser. Clin Chem.1976; 22: 1438–50.
79.
TiffanyTO. The concepts of centrifugal analysers. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 3–27.
80.
PriceCPSpencerK. Photometric performance and its relevance to chemistry performance. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 443–8.
81.
ZiegenhornJ. Enzymatic substrate analysis by use of centrifugal analysers. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 199–211.
82.
SpencerKPriceCP. A review of non enzyme mediated reactions and their applications to centrifugal analysers. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 231–53.
83.
CookJGH. Creatinine assay in the presence of protein. Clin Chim Acta1971; 32: 485–6.
84.
FabinyDLErtingshausenG. Automated reaction rate method for determination of serum creatinine with the Centrifichem. Clin Chem.1971; 17: 696–700.
85.
BartelsHBohmerM. Eine Mikromethode zur Kreatininbestimmung. Clin Chim Acta1971; 32: 81–5.
86.
LarsenK. Creatinine assay by a reaction kinetic principle. Clin Chim Acta1972; 41: 209–17.
87.
de HaanJ Bierens. Creatinine in serum and plasma. Direct microdetermination by kinetics. Anal Lett1972; 5: 815–27.
88.
GarnerRJ. Determination of creatinine. Nature1952; 170: 460–1.
89.
SpiertoFWMacNeilPMLBurtisCA. The effect of temperature and wavelength on the measurement of creatinine with the Jaffé procedure. Clin BioChem.1979; 12: 18–21.
90.
BartelsHBohmerMHierliC. Serum kreatin-bestimung ohne Enteirweissen. Clin Chim Acta1972; 3: 7193–7.
OlanskyASDemingSN. Automated development of a kinetic method for the continuous flow determination of creatinine. Clin Chem.1978; 24: 2115–24.
93.
GrafmeyerDCohenRBadinandA. Microdetermination de la creatinine dans liquides biologique par des methodes cinetiques. Annates de Biol Clin1976; 34: 283–9.
94.
HeerspinkWEisenwienerHG. Vergleichende Untersuchungen der initial rate methode des Centrifichem Systems mit der Frankonit Methode zur Bestimmung des Kreatinins in Serum und Urin. Clin Chim Acta1975; 63: 317–22.
95.
SoldinSJHendersonLHillJG. The effect of bilirubin and ketones on reaction rate methods for the measurement of creatinine. Clin BioChem.1978; 12: 18–21.
96.
KammeraatC. Modification of the alkaline picrate assay to prevent spuriously elevated values for keto acids. Clin Chim Acta1978; 84: 119–28.
97.
PriceCPSpencerKBiggsPA. An evaluation of the Instrumentation Laboratory Microcentrifugal Analyser—Multistat III. London, DHSS; 1979.
98.
ShoucriRMPouliotM. Some observations on the kinetics of the Jaffé reaction for creatinine. Clin Chem.1977; 23: 1527–30.
99.
DiamandisEPKoupparisMAHadjiioannouTP. Kinetic potentiometric determination of creatinine in urine with a picrate ion selective electrode. Microchem J1977; 22: 498–501.
100.
HadjiioannouTPDiamandisEP. Analytical study of a new picrate ion selective membrane electrode. Anal Chim Acta1981; 94: 443–8.
101.
DiamandisEPHadjiioannouTP. Kinetic potentiometric determination of creatinine in serum with a picrate ion selective membrane electrode. Clin Chem.1981; 27: 455–7.
102.
SullivanMXIrreverreF. A highly specific test for creatinine. J Biol Chem.1958; 233: 530–3.
103.
CooperJMBiggsHG. An evaluation of four methods of measuring urinary creatinine. Clin Chem.1961; 7: 665–73.
104.
Van PilsumJFMartinRPKitoE, Determination of creatine, creatinine, arginine, guanidinoacetic acid, guanidine and methylguanidine in biological fluids. J Biol Chem.1956; 222: 225–36.
105.
LangleyWDEvansM. The determination of creatinine with sodium 3,5 dinitrobenzoate. J Biol Chem.1936; 115: 333–41.
106.
BenedictSRBehreJA. Some applications of a new colour reaction for creatinine. J Biol Chem.1936; 114: 515–32.
107.
ParekhACCookSSimmsC, A new method for the determination of serum creatinine based on reaction with 3,5 dinitrobenzyl chloride in an organic medium. Clin Chim Acta1976; 73: 221–31.
108.
SimsCParekhAC. Determination of serum creatinine by reaction with methyl 3,5 dinitrobenzoate in methyl sulphoxide. Ann Clin BioChem.1977; 144: 227–32.
109.
ParekhACSimsC. Serum creatinine assay by use of 3,5 dinitrobenzoates: A critique. Clin Chem.1977; 23: 2066–71.
110.
DubosRMillerBF. The production of bacterial enzymes capable of decomposing creatinine. J Biol Chem.1937; 121: 429–45.
111.
MillerBFDubosR. Determination by a specific enzymatic method of the creatinine content of blood and urine from normal and nephrotic individuals. J Biol Chem.1937; 121: 457–64.
112.
Van EykHGVermattRJLeijnse-YbemaHJ, The conversion of creatinine by creatininase of bacterial origin. Enzymologia1968; 34: 198–202.
113.
SzulmajsterJ. Bacterial fermentation of creatinine. 1. Isolation of N methylhydantoin. J Bacteriol1958; 75: 633.
McLeanMHGallwasJHendrixsonM. Evaluation of an automated creatininase procedure. Clin Chem.1973; 19: 623–5.
116.
MassonPOhlssonPBjorkhemI. Combined enzymic—Jaffé method for the determination of creatinine in serum. Clin Chem.1981; 27: 18–21.
117.
MassonPOhlssonP. Improved precision of the enzymic—Jaffé method for determination of creatinine. Clin Chem.1981; 27: 1139.
118.
WahlefeldAWHerzGBergmeyerHU. A completely enzymatic determination of creatinine in human serum and urine. Scand J Clin Lab Invest1972; 29: Supplement 126: Abstract 30.1.
HearneCRFraserCG. Enzymatic vs Jaffé (Continuous Flow) assay of creatinine in serum. Clin Chem.1979; 25: 1665–6.
121.
BjorkhemIBlomstrandROhmanG. Accuracy of a fully enzymatic method for creatinine as judged by isotope dilution—mass fragmentography. Clin Chem.1979; 25: 1666–7.
122.
JaynesPKFeldRDJohnsonGF. An enzymic, reaction rate assay for serum creatinine with a centrifugal analyser. Clin Chem.1982; 26: 114–7.
123.
LandersmanPWLottJA. Determination of creatinine in serum by using creatinase: Enhancement of a commercial method. Clin Chem.1983; 29: 2002–3.
124.
PerakisNWolffCM. Kinetic approach for the enzymic determination of creatinine. Clin Chem.1984; 30: 1792–6.
125.
SundaramPV. Potentials of enzymes attached to nylon tubes in analysis. In: ChangTMS, ed. Biomedical applications of immobilised enzymes and proteins. New York: Plenum, 1977; II: 317–40.
126.
SundaramPVIgloiMP. Immobilised enzyme nylon tube reactors: creatininase and creatine kinase linked to the pyruvate kinase—lactate dehydrogenase indicator system in the detection of creatinine and creatine. Clin Chim Acta1979; 94: 295–307.
127.
CollissJSGinmanR. Bioluminescence as an analytical technique for determination of creatinine. Med Lab Sci.1983; 40: 129–38.
128.
SuzukiM. Purification and some properties of sarcosine oxidase from Corynebacterium sp. U-96. J BioChem.1981; 89: 599–607.
129.
FossatiPPrencipeLBertiG. Enzymic creatinine assay: A new colorimetric method based on hydrogen peroxide measurement. Clin Chem.1983; 29: 1494–6.
130.
SiedelJMolleringHZiegenhornJ. Sensitive colour reagent for the enzymic determination of creatinine. Clin Chem.1984; 30: 968–9.
131.
WitteDLBrownLFFeldRD. Effects of bilirubin on detection of hydrogen peroxide by use of peroxidase. Clin Chem.1978; 24: 1778–82.
132.
ArtissJDMcEnroeRJZakB. Bilirubin interference in a peroxidase coupled procedure for creatinine eliminated by Bilirubin Oxidase. Clin Chem.1984; 30: 1389–92.
133.
White-StevensRH. Interference by ascorbic acid in test systems involving peroxidase. 1. Reversible indicators and the effect of copper, iron and mercury. Clin Chem.1982; 28: 578–88.
134.
JamesDRPriceCP. Interference in colorimetric reactions for measuring hydrogen peroxide. Ann Clin BioChem.1984; 21: 398–404.
135.
TsuchidaTYodaK. Multienzyme membrane electrodes for determination of creatinine and creatine in serum. Clin Chem.1983; 29: 51–5.
136.
ThompsonHRechnitzGA. Ion electrode based enzymatic analysis of creatinine. Anal Chem.1974; 46: 246–9.
137.
MeyerhoffMRechnitzGA. An activated enzyme electrode for creatinine. Anal Chim Acta1976; 85: 277–85.
138.
RipamontiMMoscaARovidaE, Urea, creatinine and glucose determined in plasma and whole blood by a differential pH technique. Clin Chem.1984; 30: 556–9.
139.
BerthelotMPE. Correspondence—‘violet d'aniline’ Repertoire de chimie applique. Societe Chimique de Paris. 1859; 1: 284.
140.
TabataMKidoTTotaniM, Automated assay of creatinine in serum as simplified by the use of immobilised enzymes, creatinine deaminase and glutamate dehydrogenase. Anal BioChem.1983; 134: 44–9.
141.
TanganelliEPrencipeLBassiD, Enzymic assay of creatinine in serum and urine with creatinine iminohydrolase and glutamate dehydrogenase. Clin Chem.1982; 28: 1461–4.
142.
PrencipeLCambiaghiSMuradorE. An enzymic creatinine assay as used in centrifugal analysers. Clin Chem.1984; 30: 1583–4.
143.
ChenS-PKuanSSGuilbaultGG. Fluorometric enzymatic determination of serum creatinine on the surface of silicone rubber pads. Clin Chim Acta1980; 100: 21–31.
144.
ZippAHornbyWE. Solid phase chemistry: Its principles and application in clinical analysis. Talanta1984; 31: 863–77.
145.
WongDBergersonWOBerrethL, Solid phase strip test for the determination of serum creatinine with the Ames Seralyser. Clin Chem.1981; 27: 1034.
146.
StevensJFTsangWNewallRG. Measurement of bilirubin, cholesterol, and creatinine in serum and plasma, by solid phase reflectance spectroscopy. J Clin Path1983; 36: 598–601.
147.
SundbergMWBeckewRWEsdersTW, An enzymic creatinine assay and a direct ammonia assay in coated thin films. Clin Chem.1983; 29: 645–9.
148.
CurmeHGColumbusRLDappenGM, Multilayer film elements for clinical analysis: General concepts. Clin Chem.1978; 24: 1335–42.
149.
ToffalettiJBlosserNHallT, An automated dry slide enzymatic method evaluated for measurement of creatinine in serum. Clin Chem.1983; 29: 684–7.
150.
SmithCHLandtMSteelmanM, The Kodak Ektachem 400 analyser evaluated for automated enzymic determination of plasma creatinine. Clin Chem.1983; 29: 1422–5.
151.
ButtnerRBorthRBoutwellJH, Approved recommendation on Quality Control in Clinical Chemistry. 1. General Principles and Terminology. Clin Chim Acta1979; 98: 129F–143F.
152.
CaliJP. An idea whose time has come. Clin Chem.1973; 19: 291–3.
153.
BjorkhemIBlomstrandRLanttoO, Towards absolute methods in clinical chemistry: application of mass fragmentography to high accuracy analyses. Clin Chem.1976; 22: 1789–801.
154.
BjorkhemIBlomstrandROhmanG. Mass fragmentography of creatinine proposed as a Reference method. Clin Chem.1977; 23: 2114–21.
155.
LimCKRichmondWRobinsonDP, Towards a definitive assay of creatinine in serum and urine: Separation by high performance liquid chromatography. J Chromatog1978; 145: 41–9.
156.
BrownNDSingHCNeeleyW, Determination of true serum creatinine by high performance liquid chromatography combined with continuous flow microanalysis. Clin Chem.1977; 23: 1281–3.
157.
SoldinSJHillJG. Micromethod for determination of creatinine in biological fluids by high performance liquid chromatography. Clin Chem.1978; 24: 747–50.
158.
SpiertoFWMacNeilMLCulbrethP, Development and validation of a liquid chromatographic procedure for serum creatinine. Clin Chem.1980; 26: 286–90.
159.
AmbroseRTKetchurnDFSmithJW. Creatinine determination by high performance liquid chromatography. Clin Chem.1983; 29: 256–9.
160.
OkudaTOieTNishidaM. Liquid chromatographic measurement of creatinine in serum and urine. Clin Chem.1983; 29: 851–2.
161.
AbderhaldenEKommE. Uber die Anhydrid-strukter der Proteine. Hoppe-Seyler's Zeitschrift fur Physiolische Chemie. 1924; 139: 181.
162.
WatkinsREFelkampCSThibertRJ, Interesting interferences in a direct serum creatinine reaction. Microchem J1976; 21: 370–84.
163.
JaynesPKWitteDLSimpsonCH, Interferences by some monoclonal IgM's in discrete serum creatinine analysis. Clin Chem.1982; 28: 1580.
164.
DattaPGrahamGSchoenI. A paraprotein phenomenon evidenced by interference with creatinine determination in sera of multiple myeloma patients. Clin Chem.1984; 30: 968.
165.
WatkinsPJ. The effect of ketone bodies on the determination of creatinine. Clin Chim Acta1967; 18: 191–6.
166.
WardPEwenMPomeroyJA, Kinetic urine creatinine determination with the Gemsaec analyser. Clin BioChem.1976; 9: 225–7.
167.
PriceCPSpencerKWelchRP. Temperature measurement and the centrifugal analyser. In: PriceCPSpencerK. eds. Centrifugal Analysers in Clinical Chemistry. Eastbourne: Praeger, 1980; 381–93.
168.
BowersLD. Kinetic serum creatinine assays. 1. The role of various factors in determining specificity. Clin Chem.1980; 26: 551–4.
169.
MoriJJarvieT. Negative ketone interference with creatinine determination on the KDA. Clin Chem.1983; 29: 733–4.
170.
GerardSKhayam-BashiH. Negative interference with the Ektachem (Kodak) enzymic assay for creatinine by high serum glucose. Clin Chem.1984; 30: 1884.
171.
DaughertyNAHammondKBOsbergIM. Bilirubin interference with kinetic Jaffé method for serum creatinine. Clin Chem.1978; 24: 392–3.
172.
OsbergIMHammondKB. A solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine. Clin Chem.1978; 24: 1196–7.
173.
OsbergIM. Effect of bilirubin on serum creatinine measurement by the kinetic Jaffé method. Clin Chem.1979; 25: 325.
174.
SwainRRBiggsSL. Positive interference with the Jaffé reaction by cephalosporin antibiotics. Clin Chem.1976; 23: 1340–2.
175.
DurhamSRBignellAHCWiseR. Interference of cefoxitin in the creatinine estimation and its clinical relevance. J Clin Path1979; 32: 1148–51.
176.
KrollMHElinRJ. Mechanism of cefoxitin and cephalothin interference with the Jaffé method for creatinine. Clin Chem.1983; 29: 2044–8.
177.
KrollMHHagengruberCElinR. Effect of dialysis on interference by cefoxitin with determination of creatinine. Clin Chem.1984; 30: 1386–8.
178.
KrollMHHagengruberCElinRJ. Reaction of picrate with creatinine and cepha antibiotics. Clin Chem.1984; 30: 1664–6.
179.
RichardsRKBjornsonTHWaterburgLD. Rise in serum and urine creatinine after phenacemide. Clin Pharmacol Ther1978; 23: 430–7.
180.
KrollMHNealonLElinRJ. Phenacemide interference with Jaffé type determination of creatinine in three automated systems. Clin Chem.1984; 30: 586–7.
181.
WongLGReillyEB. Effect of Acetohexamide on serum creatinine measurement. Clin Chem.1982; 28: 1651.
182.
BooneDJDudleyDHoustonB. Effect of fatty acids on creatinine determination in serum. Clin Chem.1980; 26: 975.
183.
WitteDLPennellBJFeldRD. Elimination of non esterified fatty acid interference with creatinine measurement using alpha cyclodextrin. Clin Chem.1981; 27: 1033.
184.
WuAHBStoutRMcCombRB. Falsely high serum creatinine concentrations associated with severe methanol intoxication. Clin Chem.1983; 29: 205–8.