PinkertonTCLawsonBL.Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring: an overview. Clin Chem1982; 28: 1946–55.
10.
ClarkWM.The determination of hydrogen ions.London: Bailliere, Tindall and Cox, 1928: 221–9.
11.
CovingtonAK.Reference electrodes. In: DurstRA, ed. Ion Selective Electrodes, NBS special publication 314. Washington DC: US Government Printing Office, 1969: 107–41.
12.
WorthHGJ.A comparison of the measurement of sodium and potassium by flame photometry and ion-selective electrode. Ann Clin Biochem1985; 22: 343–50.
13.
LightTS.Industrial analysis and control with ion selective electrodes. In: DurstRA, ed. Ion Selective Electrodes, NBS special publication 314. Washington DC: US Government Printing Office, 1969: 355–6.
14.
BrandMJDRechnitzGA.Differential potentiometry with ion selective electrodes. Anal Chem1970; 42: 616–22.
15.
DurstRA.Fluoride microanalysis by null point potentiometry. Anal Chem1968; 40: 931–5.
16.
SimpsonRJ.Practical techniques for ion-selective electrodes. In: CovingtonAK, ed. Ion Selective Electrode Methodology.Florida: CRC Press, 1979; 59.
17.
MertensJvan den WinklePMassartDL.Kinetic study of the fluoride electrode in fast flow and automatic systems. Anal Chem1976; 48: 272–7.
18.
EisenmanG.Chapter 1. In: DurstRA, ed. Ion Selective Electrodes, NBS special publication 314. Washington DC: US Government Printing Office, 1969: 1–57.
19.
MoodyGJThomasJDR.Selective Ion Sensitive Electrodes.Watford: Merrow, 1971: 33–42.
20.
CovingtonAKFerraMIA.Buffer solutions for testing glass electrode performance in aqueous solutions over the pH range 0–14 at 25°C. Anal Chem1977; 49: 1363–8.
21.
MoodyGJThomasJDR. In: Selective Ion Sensitive Electrodes.Watford: Merrow, 1971: 57–88.
22.
FrantMSRossJW.Electrode for sensing fluoride ion activity in solution. Science1966; 154: 1553–5.
23.
CowellDC.Automated fluoride ion determination: Determination of urine/serum fluoride ion levels. Ann Clin Biochem1977; 14: 269–78.
24.
MoodyGJThomasJDR. In: Selective Ion Sensitive Electrodes.Watford: Merrow, 1971; 70.
25.
SzaboLKennyMALeeW.Direct measurement of chloride in sweat with an ion-selective electrode in situ. Clin Chem1973; 19: 727–30.
26.
BensonRGIsherwoodDMMcEvoyFAWoodA.Effect of temperature on response of the sweat chloride ion selective electrode. Clin Chem1982; 28: 2447–8.
27.
RossJW.Solid-state and liquid membrane ion-selective electrodes. In: DurstRA, ed. Ion Selective Electrodes, NBS special publication 314. Washington DC: US Government Printing Office, 1969: 57–88.
28.
MoodyGKOkeRBThomasJDR.A calcium selective electrode based on a liquid ion exchanger in a poly (vinyl chloride) matrix. Analyst1970; 910–8.
29.
JainMKWagnerRC.Introduction to biological membranes.Chichester: J Wiley, 1980; 192–231.
30.
CovingtonAKDavisonP.Liquid ion exchanger types. In: CovingtonAK, ed. Ion Selective Electrode Methodology.Florida: CRC Press, 1979; 94.
31.
LadensonJH.Direct potentiometric measurement of sodium and potassium in whole blood. Clin Chem1977; 23: 1912–6.
32.
MoodyGKThomasJDR. In: Selective Ion Sensitive Electrodes.Watford: Merrow, 1971; 88.
33.
CattrallRWFreiserH.Coated wire ion selective electrodes. Anal Chem1971; 43: 1905–6.
PinkertonTCLawsonBL.Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring. Clin Chem1982; 28: 1946–55.
36.
SibbaldACovingtonAKCarterRF.Simultaneous on-line measurement of blood K+, Ca2+, Na+ and pH with a four function ChemFET integrated circuit sensor. Clin Chem1984; 30: 135–7.
37.
SeveringhausJWBradleyAF.Electrodes for blood Po2 and Pco2 determinations. J Appl Physiol1958; 13: 515–20.
38.
RossJWRisemanJHKrugerJA.Potentiometric gas sensing electrodes. Pure Appl Chem1973; 36: 473–87.
39.
MeyerhoffMEFraticelliYMGreenbergJARosenJParksSJOpdykeWN.Polymer membrane electrode-based potentiometric sensing of ammonia and carbon dioxide in physiological fluids. Clin Chem1982; 28: 1973–8.
40.
BeethamR.A review of blood pH and blood gas analysis. Ann Clin Biochem1982; 19: 198–213.
41.
AttiliAFAutiziDCapocacciaL.Rapid determination of plasma ammonia using an ion specific electrode. Biochem Med.1975; 14: 109–16.
42.
RyanTHWilsonPS.Electrochemical detection in high performance liquid chromatography. Lab Practice1979; 501–506.
43.
NordenAGWFlynnFV.Halothane interference with Po2 measurements and a method of inhibiting its effects. Clin Chem Acta1979; 99: 229–34.
44.
StollMSmithBR.HPLC in clinical chemistry. ACB Technical bulletin (in preparation).
45.
VadgamaP.Enzyme electrodes as practical biosensors. J Med Eng Tech1981; 5: 293–8.
DurliatHComtatMBaudrasA.Spectrophotometric and electrochemical determinations of L(+)—lactate in blood by use of lactate dehydrogenase from yeast. Clin Chem1976; 22: 1802.
50.
PowleyCRGeigerRFNiemanRA.Bipolar pulse conductance measurements with a calcium ion-selective electrode. Anal Chem1980; 52: 705–9.
51.
RobinsonRAStokesRH.Electrolyte solutions.2nd edn.London: Butterworth and Co, 1970.
52.
CzabanJDCormierADLeggKD.Establishing the direct-potentiometric ‘Normal’ range for Na/K: Residual liquid junction potential and activity coefficient effects. Clin Chem1982; 28: 1936–45.
53.
RobertsonWG.Measurement of ionised calcium in body fluids. Ann Clin Biochem1976; 13: 540–8.
54.
ButlerJNHustonR.Activity coefficients and ion pairs in the systems sodium chloride—sodium bicarbonate—water and sodium chloride—sodium carbonate—water. J Phys Chem1970; 74: 2976–83.
55.
BaronDN.Whole plasma or plasma water: The problem of the reference base. Clin Chem1981; 27: 642.
56.
IFCC News1982; 2:5.
57.
KNA1 Handbook.Copenhagen: Radiometer Ltd.
58.
FleetBRyanTHBrandMJD.Investigation of the factors affecting the response time of a calcium selective liquid membrane electrode. Anal Chem1974; 46: 12–15.
59.
CovingtonAKRobinsonRA.Reference standards for the electrometric determination with ion-selective electrodes of potassium and calcium in blood. Anal Chim Acta1975; 78: 219–24.
60.
KaufmanRATietzNW.Ion effects in measurement of ionised calcium with a calcium-selective electrode. Clin Chem1980; 26: 640–4.
61.
DurstRA.Automated analyzer for the determination of potassium and sodium in whole blood. Clin Chim Acta1977; 80: 225–34.