A 43 year old man with a Hancock porcine bioprosthetic valve in the mitral position developed a huge thombus filling the entire left atrium and chronic degeneration of the bioprosthetic mitral valve. The effective valve orifice was less than 2 mm. These severe findings leading to the patient's death remained undetected while he was alive. This case illustrates the great need for a serial phonoechocardiographic studies in all patients with prosthetic valves.
Get full access to this article
View all access options for this article.
References
1.
Cohn HL, Sanders JH, Collins JL: Actuarial comparison of Hancock porcine and prosthetic disc valves for isolated mitral valve replacement. Circ 54 Supp III : 60-63, 1976.
2.
Cohn LH, et al: Long term follow-up of the Hancock bioprosthetic heart valve: a six year review. Circulation60: 87, 1979.
3.
Salomon NW, Stinson EB, Griepp RB, et al: Mitral valve replacement: Long term evaluation of prosthesis-related mortality and morbidity. Circ56(SupplII): 9, 1977.
4.
Angell WW, Angell JD, Sywak A., et al: The tissue valve as a superior cardiac valve replacement. Surgery82: 875, 1977.
5.
Braunwald EP : Valvular heart disease in Heart Disease. Ed. by Braunwald E. Philadelphia, W.B. Saunders, 1980, pp. 1095-1165.
6.
Ishihara O., Ferrans VJ, Boyce SW, et al. Structure and classification of cuspal tears and perforation in porcine bioprosthetic cardiac valves implanted in patients. Am J Cardiol49: 665-668, 1981.
7.
Stein PD, Sabbah MN, Mazilligan DJ Jr, et al: Mechanism of a musical systolic murmur caused by a degenerated porcine bioprosthetic valve. Am J of Cardiol49: 1874-1882, 1982.
8.
Smith ND, Raizada V., Abrams J.: Auscultation of the normally functioning prosthetic valve. Annals of Int Med95: 594-598, 1981.
9.
Zoneraich O., Zoneraich S.: Phonocardiographic findings in patients with malfunctioning artificial valves. In: Noninvasive Methods in Cardiology. Ed. by Zoneraich S. Springfield, Ch. C. Thomas, 1975, pp. 421-431.
10.
Alan M., Madiazo AC, Magilligan DJ, et al : M-mode and two dimensional echocardiographic features of porcine valve dysfunction. Am J Cardiol43: 502, 1979.
11.
Schapira JN, Martin RP, Fowles RE, et al: Two-dimensional echocardiographic assessment of patients with bioprosthetic valves. Am J Cardiol43: 510, 1979.
12.
Weyman AE: Cross-sectional Echocardiography. Lea and Febiger , Philadelphia, 1982, pp. 184-188.
13.
Zoneraich S. , Zoneraich O., Silverman G.: Evaluation of M- and 2-D Echocardiography in the diagnosis of left ventricular thrombi. Patho-anatomical correlations. Proceedings Annual Meeting Am. Inst. of Ultrasound in Medicine: Montreal, 1979, p. 52.
14.
Feigenbaum H.: Left atrial thrombi in echocardiography. Philadelphia, Lea and Febiger, 1981, pp. 520-522.
15.
Naito H., Ohta M., Malda F.: Angiographic and phonocardiographic evaluation of the Hancock bioprosthetic valve. Japan J of Cardiography11: 359-370, 1981.