A fixed procedure of strain gauge plethysmography in a control population aged between 20-30 years allows normal values for venous parameters (venous distensibility, emptying, and resistance) and capillary filtration coefficient, to be determined. High speed recording reveals two phases in venous emptying, one passive, purely elastic, and a second active phase, resulting from venous constriction.
Get full access to this article
View all access options for this article.
References
1.
Whitney, R.J. : Measurement of changes in human limb volume by means of a mercury-in-rubber strain gauge. J. Physiol. , 109: 5, 1949.
2.
Brugmans, J. , Jageneau, A., Hörig, C., et al.: Modern techniques of venous occlusion plethysmography in the assessment of peripheral vascular disease. Proc. Roy. Soc. Med., 70: (Suppl) 1, 1977.
3.
Pointel, J.P., Drouin, P., Vernhès, G., et al.: Standardisation des techniques. La Plethysmographie, in Le Laboratoire d'Explorations Vasculaires. Edited by H. Boccalon, P. Puel, and A. Enjalbert.Toulouse, France, 1980, pp. 29-51.
4.
Barnes, R.W. , Hokanson, D.E., Wu, D.D., et al.: Detection of deep vein thrombosis with an automatic electrically calibrated strain gauge plethysmograph. Surgery, 82: 219, 1977.
5.
D'Inverno, E., Peeters, M.: Clinical use of plethysmography in the diagnosis of deep venous thrombosis and arterial occlusive disease. Twentieth Annual Meeting of the International College of Angiology, Marbella , Spain, October 29-November 2, 1978.
6.
Forconi, S., Jageneau, A., Guerrini, M., et al.: Strain gauge plethysmography in the study of circulation of the limbs. Angiology, 30: 487, 1979.
7.
Hellige, G., Ensink, F.B.M., Baller, D., et al.: Measurement of arterial and venous reactivity by an advanced strain gauge plethysmogra. Angiology, 30: 539, 1979.
8.
Johnston, K.W. , Kakkar, V.V.: Plethysmographic diagnosis of deep vein thrombosis. Surg. Gynecol. Obstet., 139: 41, 1974.
9.
Lepore, T.J. , Savran, J., Van de Walter, J., et al.: Screening for lower extremity deep venous thrombosis. An improved plethysmographic and doppler approach. Am. J. Surg., 135: 529, 1978.
10.
Hallbook, T. , Göthlin, J.: Strain gauge plethysmography and phlebography in diagnosis of deep venous thrombosis. Acta Chir. Scand. , 137: 37, 1971.