Gosling, R.G., King, D.H.: Continuous wave ultrasound as an alternative and complement to x-rays in vascular examinations, in Cardiovascular Applications of Ultrasound. Edited by R. S. Reneman. Amsterdam, North-Holland Publishing, 1974, p. 266.
2.
Spencer, M.P. , Reid, J.M.: Quantitation of carotid stenosis with CW Doppler ultrasound. Stroke, in press.
3.
Barnes, R.W. , Bone, G.E., Reinertson , J., et al.: Non-invasive ultrasonic carotid angiography: Prospective validation by contrast arteriography . Surgery , 80: 328, 1976.
4.
Giddens, D.P. , Mabon, R.F., Cassanova , R.A.: Measurements of disordered flows distal to subtotal vascular stenoses in the thoracic aortas of dogs. Circ. Res., 39: 112, 1976.
5.
Reneman, R.S. , Spencer, M.P.: Local Doppler audio spectra in normal and stenosed carotid arteries in man. Ultrasound Med. Biol. In press.
6.
Sandmann, W., Peronneau, P., Schweins, G., et al.: Turbulenzmessung mit dem Doppler-Ultraschallverfahren: Eine neue Methode der Qualitätskontrolle in der Arterienchirurgie, in Ultraschall-Doppler-Diagnostik in der Angiologie. Edited by A. Kriesmann and A. Bollinger.Stuttgart, Georg Thieme Verlag , 1978, p. 77.
7.
Mozersky, D.J. , Hokanson, D.E., Sumner , D.S., et al.: Ultrasonic visualization of the arterial lumen. Surgery, 72: 253, 1972.
Spencer, M.P. , Reid, J.M., Davis , D.L., et al.: Cervical carotid imaging with a continuous-wave Doppler flowmeter. Stroke, 5: 145, 1974.
10.
Fish, P.J.: Multichannel, direction-resolving Doppler angiography. Excerpta Medica International Congress Series No. 363. Amsterdam , Excerpta Medica, 1975 , p. 153.
11.
Bollinger, A., Schlumph, M., Butti , P., et al.: Measurement of systolic ankle blood pressure with Doppler ultrasound at rest and after exercise in patients with leg artery occlusions. Scand. J. Clin. Lab. Invest., 31: 123, 1973 (Suppl. 128).
12.
Lewis, J.D., Yao, S.T.: Waveform and pressure measurement with a directional Doppler in the diagnosis and follow-up of peripheral arterial disease, in Cardiovascular Applications of Ultrasound. Edited by R. S. Reneman.Amsterdam, North-Holland Publishing, 1974, p. 294.
Reneman, R.S. , Clarke, H.F., Simmons , N., et al.: In vivo comparison of electromagnetic and Doppler flowmeters: With special attention to the processing of the analogue Doppler flow signal. Cardiovasc. Res., 7: 557, 1973.
17.
Reneman, R.S. , Spencer, M.P.: Difficulties in processing of an analogue Doppler flow signal: With special reference to zero-crossing meters and quantification , in Cardiovascular Applications of Ultrasound . Edited by R. S. Reneman.Amsterdam , North-Holland Publishing, 1974 , p. 32.
18.
Reneman, R.S. , Hoeks, A.: Continuous wave and pulsed Doppler flowmeters—a general introduction, in Echocardiology With Doppler Applications and Real Time Imaging. The Hague , Martinus Nijhoff, 1977, p. 189.
19.
Franklin, D.L. , Schlegel, W., Rushmer , R.F.: Blood flow measured by Doppler frequency shift of backscattered ultrasound. Science , 134: 564, 1961.
20.
Stegall, H.F. , Rushmer, R.F., Baker , D.W.: A transcutaneous ultrasonic blood velocity meter. J. Appl. Physiol., 21: 707, 1966.
21.
Rushmer, R.F. , Baker, D.W., Johnson , W.L., et al.: Clinical applications of a transcutaneous ultrasonic flow detector. JAMA, 199: 326, 1967 .
22.
Peronneau, P., Hinglais, J., Pellet , M., et al.: Vélocimètre sanguin effet Doppler à émission ultra-sonore pulsée. Onde Electrique, 50: 369, 1970.
23.
Jorgensen, J.E., Campau, D.N., Baker , D.W.: Physical characteristics and mathematical modelling of the pulsed ultrasonic flowmeter. Med. Biol. Eng. , July: 404, 1973 .
24.
Baker, D.W., Johnson, S.L., Strandness, D.E.: Prospects of quantitation of transcutaneous pulsed Doppler techniques in cardiology and peripheral vascular diseases, in Cardiovascular Applications of Ultrasound. Edited by R. S. Reneman.Amsterdam, North-Holland Publishing, 1974, p. 108.
25.
Peronneau, P. , Bournat, J.P., Bugnon , A., et al.: Theoretical and practical aspects of pulsed Doppler flowmetry: Real-time application to the measure of instantaneous velocity profiles in vitro and in vivo, in Cardiovascular Applications of Ultrasound. Edited by R. S. Reneman.Amsterdam, North-Holland Publishing, 1974, p. 66.
26.
Brandestini, M.: Signalverarbeitung in perkutanen Ultraschall Doppler Blutfluss Messgeräten. Dissertation Swiss Federal Institute of Technology, ETH5911, 1976.
27.
Hoeks, A.: A multichannel pulsed Doppler system with serial data processing. In preparation.
28.
Gessner, U. : The performance of the ultrasonic flowmeter in complex velocity profiles. IEEE Trans. Biomed. Eng. BME -16: 139, 1969.
Lezack, J.D. , Carter, S.A.: The relationship of distal systolic pressures to the clinical and angiographic findings in limbs with arterial occlusive disease. Scand. J. Clin. Lab. Invest., 31: 97, 1973 (Suppl. 128).
31.
Sumner, D.S. , Strandness, D.E.: The relationship between calf blood flow and ankle blood pressure in patients with intermittent claudication . Surgery, 65: 763, 1969.
32.
Mol, J.M.F., Rijcken, W.J.: Doppler haematotachographic investigation in cerebral circulation disturbances, in Cardiovascular Applications of Ultrasound. Edited by R. S. Reneman. Amsterdam, North-Holland Publishing, 1974, p. 305.