Mendlowitz, M. and Naftchi, N.: The digital circulation in Raynaud's disease . Am. J. Cardiol.4: 580 (1959)
2.
Peacock, J.H. : The effect of changes in local temperature on the blood flow of the normal hand, primary Raynaud's disease and primary acrocyanosis. Clin. Sci.19: 505 (1960)
3.
Evans, W.: Diseases of the heart and arteries. Edinburgh and London1964. E. S. Living-stone Ltd.
4.
Lewis, T.: Experiments relating to the peripheral mechanism involved in spasmodic arrest of the circulation in the fingers, a variety of Raynaud's disease. Heart15: 7(1929)
Simpson, L.S. , Brown, O.G.E. and Adson, A.W.: Raynaud's disease. Evidence that it is a type of vasomotor neurosis. Arch. Neurol. and Psych.26: 687 (1931)
7.
Hyndman, O.R. and Wolkin, J.: Raynaud's disease. A review of its mechanism with evidence that it is primarily a vascular disease. Am. Heart. J.23: 535 (1942)
8.
Hertzmann, A.B. and Roth, L.W.: The vasomotor components in the vascular reactions in the finger to cold. Am. J. Physiol.136: 669 (1942)
9.
Rapaport, S.I. , Fetcher, E.S., Shaub, H.G. and Hall, J.F.: Control of blood flow to the extremities at low ambient temperature. J. Appl. Physiol2: 61 ( 1949)
10.
Gaskell, P. and Diosy, A.: Influence of local temperature and of digital nerve block on critical opening pressure of vessels in the finger. Circulation Res. 7: 1000 (1959)
11.
Edwards, E.A. : Varieties of digital ischemia and their management . New Eng. J. Med.250: 709 (1954)
12.
Lottenbach, K.: Vasomotor tone and local vasoconstrictor responses induced by cold. Angiologica5: 377 (1968)
13.
Mendlowitz, M. : The digital circulation. New York1954. Grune and Stratton.
14.
Arnott, W.M. and Macfie. J.M.: Effect of ulnar nerve block on blood flow in the reflexly vasodilated digit. J. Physiol.107: 233 (1948)
15.
Burton, A.C.: A critical survey of methods available for the measurement of human peripheral blood flow. Peripheral Circulation in man. London1954. J. A. Churchill Ltd.
16.
Cooper, K.E. , Cross, K.W., Greenfield, A.D.M., Hamilton, D.McK. and Scarbourough, H.: A comparison of methods for gauging the blood flow through the hand. Clin. Sci.8: 217 (1949)
17.
Greenfield, A.D.M. and Scarbourough , H.: An improved calorimeter for the hand. Clin. Sci.8: 211 (1949)
18.
Lottenbach, K.: Arterielle Temperatur und Durchblutung des Fingers. Angiologica4: 28 (1967)
19.
Gibbon, J.H. and Landis. E. M.: Vasodilatation in the lower extremities in response to immersing the forearms in warm water. J. Clin. Invest.11: 1019 (1932)
20.
Lewis, T.: Vascular disorders of the limbs. London1946. MacMillan.
21.
Burn, J.H. and Rand. M. J.: Noradrenaline in artery walls and its dispersal by reserpine. Brit. Med. J.1: 903 (1958)
22.
Laszt, L.: Untersuchungen über die Temperaturwirkung auf den Gefässwandtonus. Angiologica3: 279 (1966)