Tricuspid valve perforation with pacemaker lead is one of the extremely rare complications of transvenous pacemaker implantation. Approximately all reported cases have been diagnosed at autopsy. The authors present a case of tricuspid valve perforation caused by pacemaker lead that was diagnosed during cardiac surgery and treated successfully by removing the lead and suturing the tricuspid valve.
Get full access to this article
View all access options for this article.
References
1.
Barold S: Complications of pacemaker implantation and troubleshooting. In: Interventional Electrophysiology, ed. by Singer I.Baltimore: Williams and Wilkins, 1997, pp 913-1054.
2.
Morgan DE, Norman R, West RD, et al: Echocardiographic assessment of tricuspid regurgitation during ventricular pacing. Am J Cardiol58:1025-1029, 1986.
3.
Mühler E, von Bernuth G: Severe tricuspid valve regurgitation caused by transvenous pacemaker: Echocardiographic diagnosis. Am Heart J113:1029-1031, 1987.
4.
Old WD, Paulsen W, Lewis SA, et al: Pacemaker lead-induced tricuspid stenosis: Diagnosis by Doppler echocardiography. Am Heart J117:1165-1167, 1989.
5.
Hagers Y, Koole M, Schoors D, et al: Tricuspid stenosis: A rare complication of pacemaker-related endocarditis. J Am Soc Echocardiogr13:66-68, 2000.
6.
Frandsen F, Oxhøj H, Nielsen B: Entrapment of a tined pacemaker electrode in the tricuspid valve. A case report. Pacing Clin Electrophysiol13:1082-1083, 1990.
7.
Durack DT, Lukes AS, Bright DK: New criteria for diagnosis of infective endocarditis: Utilization of specific echocardiographic findings. Duke Endocarditis Service. Am J Med96:200-209, 1994.
8.
Fishenfield J, Lamy Y: Laceration of the tricuspid valve by a pacemaker wire. Chest61:697-698, 1972.
9.
Petterson SR, Singh JB, Reeves G, et al: Tricuspid valve perforation by endocardial pacing electrode. Chest63:125-126, 1973.
10.
Gould L, Reddy CVR, Yacob U, et al: Perforation of the tricuspid valve by a transvenous pacemaker. JAMA230:86-87, 1986.
11.
Christie JL, Keelan MH Jr: Tricuspid valve perforation by a permanent pacing lead in a patient with cardiac amyloidosis: Case report and brief literature review. Pacing Clin Electrophysiol9:124-126, 1986.
12.
Rubio AP, Al-Bassam MS: Pacemaker-lead puncture of the tricuspid valve. Chest99:1519-1520, 1991.
13.
Shirato C, Ishikawa K: Newly developed systolic murmur in patients with a transvenous pacemaker. Am Heart J99:722-726, 1980.
14.
Gibson TC, Davidson RC, De Silvey DL: Presumptive tricuspid valve malfunction induced by a pacemaker lead. A case report and review of the literature. Pacing Clin Electrophysiol3:88-95, 1980.